UHF PD measurements on power transformers-advantages and limitations

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Hamid Jahangir
  • Asghar Akbari Azirani
  • Peter Werle
  • Janusz Szczechowski

External Research Organisations

  • K.N. Toosi University of Technology
  • ABB Group
View graph of relations

Details

Original languageEnglish
Pages (from-to)3933-3940
Number of pages8
JournalIEEE Transactions on Dielectrics and Electrical Insulation
Volume24
Issue number6
Publication statusPublished - Dec 2017

Abstract

Recently, Ultra-High Frequency (UHF) Partial Discharge (PD) measurements on power transformers has attracted a lot of attention. Despite numerous publications, there are still missing information about considerations and limitations of this method in regards to antenna characteristics, relation between IEC 60270 and UHF detection methods and robustness against external noises. In this paper, each of the mentioned sections is investigated in detail by simulation analysis or laboratory measurements. Applying the results obtained in each section leads to a more precise measurement, more accurate analysis of UHF PD data and solving some of the problems associated with it.

Keywords

    Calibration, external noise, partial discharge, power transformer, UHF antenna

ASJC Scopus subject areas

Cite this

UHF PD measurements on power transformers-advantages and limitations. / Jahangir, Hamid; Akbari Azirani, Asghar; Werle, Peter et al.
In: IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 24, No. 6, 12.2017, p. 3933-3940.

Research output: Contribution to journalArticleResearchpeer review

Jahangir H, Akbari Azirani A, Werle P, Szczechowski J. UHF PD measurements on power transformers-advantages and limitations. IEEE Transactions on Dielectrics and Electrical Insulation. 2017 Dec;24(6):3933-3940. doi: 10.1109/TDEI.2017.006149
Jahangir, Hamid ; Akbari Azirani, Asghar ; Werle, Peter et al. / UHF PD measurements on power transformers-advantages and limitations. In: IEEE Transactions on Dielectrics and Electrical Insulation. 2017 ; Vol. 24, No. 6. pp. 3933-3940.
Download
@article{9f70b7ec926245448fadef325065b4e5,
title = "UHF PD measurements on power transformers-advantages and limitations",
abstract = "Recently, Ultra-High Frequency (UHF) Partial Discharge (PD) measurements on power transformers has attracted a lot of attention. Despite numerous publications, there are still missing information about considerations and limitations of this method in regards to antenna characteristics, relation between IEC 60270 and UHF detection methods and robustness against external noises. In this paper, each of the mentioned sections is investigated in detail by simulation analysis or laboratory measurements. Applying the results obtained in each section leads to a more precise measurement, more accurate analysis of UHF PD data and solving some of the problems associated with it.",
keywords = "Calibration, external noise, partial discharge, power transformer, UHF antenna",
author = "Hamid Jahangir and {Akbari Azirani}, Asghar and Peter Werle and Janusz Szczechowski",
note = "Publisher Copyright: {\textcopyright} 1994-2012 IEEE. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.",
year = "2017",
month = dec,
doi = "10.1109/TDEI.2017.006149",
language = "English",
volume = "24",
pages = "3933--3940",
journal = "IEEE Transactions on Dielectrics and Electrical Insulation",
issn = "1070-9878",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "6",

}

Download

TY - JOUR

T1 - UHF PD measurements on power transformers-advantages and limitations

AU - Jahangir, Hamid

AU - Akbari Azirani, Asghar

AU - Werle, Peter

AU - Szczechowski, Janusz

N1 - Publisher Copyright: © 1994-2012 IEEE. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.

PY - 2017/12

Y1 - 2017/12

N2 - Recently, Ultra-High Frequency (UHF) Partial Discharge (PD) measurements on power transformers has attracted a lot of attention. Despite numerous publications, there are still missing information about considerations and limitations of this method in regards to antenna characteristics, relation between IEC 60270 and UHF detection methods and robustness against external noises. In this paper, each of the mentioned sections is investigated in detail by simulation analysis or laboratory measurements. Applying the results obtained in each section leads to a more precise measurement, more accurate analysis of UHF PD data and solving some of the problems associated with it.

AB - Recently, Ultra-High Frequency (UHF) Partial Discharge (PD) measurements on power transformers has attracted a lot of attention. Despite numerous publications, there are still missing information about considerations and limitations of this method in regards to antenna characteristics, relation between IEC 60270 and UHF detection methods and robustness against external noises. In this paper, each of the mentioned sections is investigated in detail by simulation analysis or laboratory measurements. Applying the results obtained in each section leads to a more precise measurement, more accurate analysis of UHF PD data and solving some of the problems associated with it.

KW - Calibration

KW - external noise

KW - partial discharge

KW - power transformer

KW - UHF antenna

UR - http://www.scopus.com/inward/record.url?scp=85038825728&partnerID=8YFLogxK

U2 - 10.1109/TDEI.2017.006149

DO - 10.1109/TDEI.2017.006149

M3 - Article

AN - SCOPUS:85038825728

VL - 24

SP - 3933

EP - 3940

JO - IEEE Transactions on Dielectrics and Electrical Insulation

JF - IEEE Transactions on Dielectrics and Electrical Insulation

SN - 1070-9878

IS - 6

ER -

By the same author(s)