UHF characteristics of different types of PD sources in power transformers

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

  • Hamid Jahangir
  • Asghar Akbari
  • Peter Werle
  • Mohammad Akbari
  • Janusz Szczechowski

External Research Organisations

  • K.N. Toosi University of Technology
  • ABB Group
View graph of relations

Details

Original languageEnglish
Title of host publication2017 25th Iranian Conference on Electrical Engineering, ICEE 2017
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1242-1247
Number of pages6
ISBN (electronic)9781509059638
Publication statusPublished - 19 Jul 2017
Event25th Iranian Conference on Electrical Engineering, ICEE 2017 - Tehran, Iran, Islamic Republic of
Duration: 2 May 20174 May 2017

Abstract

Recently, partial discharge (PD) measurement in power transformers using ultra high frequency (UHF) techniques attracts a lot of attentions. But, most investigations on the subject are focused on detection of electromagnetic (EM) waves e.g. design of proper antennas and localization of PD source where just deals with starting point of the UHF signal. Thus, analysis of UHF data including waveforms and patterns is less performed. In this paper, an investigation on influence of PD type on UHF signals in phase domain is presented to find if there is any difference between UHF and IEC patterns. Moreover, UHF PD waveforms in time and frequency domains is studied to realize effect of transformer tank, antenna characteristics and type of PD on them.

Keywords

    Partial discharge, PD type, Power transformer, UHF measurement

ASJC Scopus subject areas

Cite this

UHF characteristics of different types of PD sources in power transformers. / Jahangir, Hamid; Akbari, Asghar; Werle, Peter et al.
2017 25th Iranian Conference on Electrical Engineering, ICEE 2017. Institute of Electrical and Electronics Engineers Inc., 2017. p. 1242-1247 7985232.

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Jahangir, H, Akbari, A, Werle, P, Akbari, M & Szczechowski, J 2017, UHF characteristics of different types of PD sources in power transformers. in 2017 25th Iranian Conference on Electrical Engineering, ICEE 2017., 7985232, Institute of Electrical and Electronics Engineers Inc., pp. 1242-1247, 25th Iranian Conference on Electrical Engineering, ICEE 2017, Tehran, Iran, Islamic Republic of, 2 May 2017. https://doi.org/10.1109/IranianCEE.2017.7985232
Jahangir, H., Akbari, A., Werle, P., Akbari, M., & Szczechowski, J. (2017). UHF characteristics of different types of PD sources in power transformers. In 2017 25th Iranian Conference on Electrical Engineering, ICEE 2017 (pp. 1242-1247). Article 7985232 Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/IranianCEE.2017.7985232
Jahangir H, Akbari A, Werle P, Akbari M, Szczechowski J. UHF characteristics of different types of PD sources in power transformers. In 2017 25th Iranian Conference on Electrical Engineering, ICEE 2017. Institute of Electrical and Electronics Engineers Inc. 2017. p. 1242-1247. 7985232 doi: 10.1109/IranianCEE.2017.7985232
Jahangir, Hamid ; Akbari, Asghar ; Werle, Peter et al. / UHF characteristics of different types of PD sources in power transformers. 2017 25th Iranian Conference on Electrical Engineering, ICEE 2017. Institute of Electrical and Electronics Engineers Inc., 2017. pp. 1242-1247
Download
@inproceedings{cc1e99b3924d492498fb3c859c4e74bb,
title = "UHF characteristics of different types of PD sources in power transformers",
abstract = "Recently, partial discharge (PD) measurement in power transformers using ultra high frequency (UHF) techniques attracts a lot of attentions. But, most investigations on the subject are focused on detection of electromagnetic (EM) waves e.g. design of proper antennas and localization of PD source where just deals with starting point of the UHF signal. Thus, analysis of UHF data including waveforms and patterns is less performed. In this paper, an investigation on influence of PD type on UHF signals in phase domain is presented to find if there is any difference between UHF and IEC patterns. Moreover, UHF PD waveforms in time and frequency domains is studied to realize effect of transformer tank, antenna characteristics and type of PD on them.",
keywords = "Partial discharge, PD type, Power transformer, UHF measurement",
author = "Hamid Jahangir and Asghar Akbari and Peter Werle and Mohammad Akbari and Janusz Szczechowski",
note = "Publisher Copyright: {\textcopyright} 2017 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.; 25th Iranian Conference on Electrical Engineering, ICEE 2017 ; Conference date: 02-05-2017 Through 04-05-2017",
year = "2017",
month = jul,
day = "19",
doi = "10.1109/IranianCEE.2017.7985232",
language = "English",
pages = "1242--1247",
booktitle = "2017 25th Iranian Conference on Electrical Engineering, ICEE 2017",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
address = "United States",

}

Download

TY - GEN

T1 - UHF characteristics of different types of PD sources in power transformers

AU - Jahangir, Hamid

AU - Akbari, Asghar

AU - Werle, Peter

AU - Akbari, Mohammad

AU - Szczechowski, Janusz

N1 - Publisher Copyright: © 2017 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.

PY - 2017/7/19

Y1 - 2017/7/19

N2 - Recently, partial discharge (PD) measurement in power transformers using ultra high frequency (UHF) techniques attracts a lot of attentions. But, most investigations on the subject are focused on detection of electromagnetic (EM) waves e.g. design of proper antennas and localization of PD source where just deals with starting point of the UHF signal. Thus, analysis of UHF data including waveforms and patterns is less performed. In this paper, an investigation on influence of PD type on UHF signals in phase domain is presented to find if there is any difference between UHF and IEC patterns. Moreover, UHF PD waveforms in time and frequency domains is studied to realize effect of transformer tank, antenna characteristics and type of PD on them.

AB - Recently, partial discharge (PD) measurement in power transformers using ultra high frequency (UHF) techniques attracts a lot of attentions. But, most investigations on the subject are focused on detection of electromagnetic (EM) waves e.g. design of proper antennas and localization of PD source where just deals with starting point of the UHF signal. Thus, analysis of UHF data including waveforms and patterns is less performed. In this paper, an investigation on influence of PD type on UHF signals in phase domain is presented to find if there is any difference between UHF and IEC patterns. Moreover, UHF PD waveforms in time and frequency domains is studied to realize effect of transformer tank, antenna characteristics and type of PD on them.

KW - Partial discharge

KW - PD type

KW - Power transformer

KW - UHF measurement

UR - http://www.scopus.com/inward/record.url?scp=85032806080&partnerID=8YFLogxK

U2 - 10.1109/IranianCEE.2017.7985232

DO - 10.1109/IranianCEE.2017.7985232

M3 - Conference contribution

AN - SCOPUS:85032806080

SP - 1242

EP - 1247

BT - 2017 25th Iranian Conference on Electrical Engineering, ICEE 2017

PB - Institute of Electrical and Electronics Engineers Inc.

T2 - 25th Iranian Conference on Electrical Engineering, ICEE 2017

Y2 - 2 May 2017 through 4 May 2017

ER -

By the same author(s)