Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis

Research output: Contribution to journalArticleResearchpeer review

Authors

  • S. Beier
  • Stephan Köster
  • K. Veltmann
  • H. Fr Schröder
  • J. Pinnekamp

External Research Organisations

  • RWTH Aachen University
View graph of relations

Details

Original languageEnglish
Pages (from-to)1691-1698
Number of pages8
JournalWater science and technology
Volume61
Issue number7
Publication statusPublished - 20 Jul 2010
Externally publishedYes

Abstract

Considerable concern exists regarding the appearance and effects of trace and ultra trace pollutants in the aquatic environment. In this context, it is necessary to identify relevant hot spot wastewater - such as hospital wastewater - and to implement specific wastewater treatment solutions. Membrane bioreactor (MBR) technology seems to be a suitable pre-treatment approach for the subsequent advanced treatment by high pressure membrane systems such as nanofiltration (NF) and reverse osmosis (RO). This paper is based upon investigations on the first full scale MBR for separate treatment of hospital wastewater in Germany. In this study an NF as well as an RO module for further treatment of the MBR filtrate were tested. The removal efficiencies were assessed using the following target compounds: bezafibrate, bisoprolol, carbamazepine, clarithromycin, ciprofloxacin, diclofenac, ibuprofen, metronidazole, moxifloxacin, telmisartan and tramadol. In summary, the results of this study confirmed that MBR technology followed by an advanced treatment for trace pollutant removal is an adequate approach for specific treatment of hot spot wastewater such as hospital wastewater. In particular, it was shown that - comparing the tested NF and RO - only (a two stage) RO is appropriate to remove pharmaceutical residues from hospital wastewater entirely. The recommended yield of the 2-stage RO is 70% which results in a retentate sidestream of 9%. Our investigations proved that RO is a very efficient treatment approach for elimination of trace pollutants.

Keywords

    Hospital wastewater, Membrane bioreactor, Nanofiltration, Pharmaceutical residues, Reverse osmosis

ASJC Scopus subject areas

Cite this

Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis. / Beier, S.; Köster, Stephan; Veltmann, K. et al.
In: Water science and technology, Vol. 61, No. 7, 20.07.2010, p. 1691-1698.

Research output: Contribution to journalArticleResearchpeer review

Beier, S, Köster, S, Veltmann, K, Schröder, HF & Pinnekamp, J 2010, 'Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis', Water science and technology, vol. 61, no. 7, pp. 1691-1698. https://doi.org/10.2166/wst.2010.119
Beier, S., Köster, S., Veltmann, K., Schröder, H. F., & Pinnekamp, J. (2010). Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis. Water science and technology, 61(7), 1691-1698. https://doi.org/10.2166/wst.2010.119
Beier S, Köster S, Veltmann K, Schröder HF, Pinnekamp J. Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis. Water science and technology. 2010 Jul 20;61(7):1691-1698. doi: 10.2166/wst.2010.119
Beier, S. ; Köster, Stephan ; Veltmann, K. et al. / Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis. In: Water science and technology. 2010 ; Vol. 61, No. 7. pp. 1691-1698.
Download
@article{d939014705964ec0b137d382ac4e0062,
title = "Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis",
abstract = "Considerable concern exists regarding the appearance and effects of trace and ultra trace pollutants in the aquatic environment. In this context, it is necessary to identify relevant hot spot wastewater - such as hospital wastewater - and to implement specific wastewater treatment solutions. Membrane bioreactor (MBR) technology seems to be a suitable pre-treatment approach for the subsequent advanced treatment by high pressure membrane systems such as nanofiltration (NF) and reverse osmosis (RO). This paper is based upon investigations on the first full scale MBR for separate treatment of hospital wastewater in Germany. In this study an NF as well as an RO module for further treatment of the MBR filtrate were tested. The removal efficiencies were assessed using the following target compounds: bezafibrate, bisoprolol, carbamazepine, clarithromycin, ciprofloxacin, diclofenac, ibuprofen, metronidazole, moxifloxacin, telmisartan and tramadol. In summary, the results of this study confirmed that MBR technology followed by an advanced treatment for trace pollutant removal is an adequate approach for specific treatment of hot spot wastewater such as hospital wastewater. In particular, it was shown that - comparing the tested NF and RO - only (a two stage) RO is appropriate to remove pharmaceutical residues from hospital wastewater entirely. The recommended yield of the 2-stage RO is 70% which results in a retentate sidestream of 9%. Our investigations proved that RO is a very efficient treatment approach for elimination of trace pollutants.",
keywords = "Hospital wastewater, Membrane bioreactor, Nanofiltration, Pharmaceutical residues, Reverse osmosis",
author = "S. Beier and Stephan K{\"o}ster and K. Veltmann and Schr{\"o}der, {H. Fr} and J. Pinnekamp",
year = "2010",
month = jul,
day = "20",
doi = "10.2166/wst.2010.119",
language = "English",
volume = "61",
pages = "1691--1698",
journal = "Water science and technology",
issn = "0273-1223",
publisher = "IWA Publishing",
number = "7",

}

Download

TY - JOUR

T1 - Treatment of hospital wastewater effluent by nanofiltration and reverse osmosis

AU - Beier, S.

AU - Köster, Stephan

AU - Veltmann, K.

AU - Schröder, H. Fr

AU - Pinnekamp, J.

PY - 2010/7/20

Y1 - 2010/7/20

N2 - Considerable concern exists regarding the appearance and effects of trace and ultra trace pollutants in the aquatic environment. In this context, it is necessary to identify relevant hot spot wastewater - such as hospital wastewater - and to implement specific wastewater treatment solutions. Membrane bioreactor (MBR) technology seems to be a suitable pre-treatment approach for the subsequent advanced treatment by high pressure membrane systems such as nanofiltration (NF) and reverse osmosis (RO). This paper is based upon investigations on the first full scale MBR for separate treatment of hospital wastewater in Germany. In this study an NF as well as an RO module for further treatment of the MBR filtrate were tested. The removal efficiencies were assessed using the following target compounds: bezafibrate, bisoprolol, carbamazepine, clarithromycin, ciprofloxacin, diclofenac, ibuprofen, metronidazole, moxifloxacin, telmisartan and tramadol. In summary, the results of this study confirmed that MBR technology followed by an advanced treatment for trace pollutant removal is an adequate approach for specific treatment of hot spot wastewater such as hospital wastewater. In particular, it was shown that - comparing the tested NF and RO - only (a two stage) RO is appropriate to remove pharmaceutical residues from hospital wastewater entirely. The recommended yield of the 2-stage RO is 70% which results in a retentate sidestream of 9%. Our investigations proved that RO is a very efficient treatment approach for elimination of trace pollutants.

AB - Considerable concern exists regarding the appearance and effects of trace and ultra trace pollutants in the aquatic environment. In this context, it is necessary to identify relevant hot spot wastewater - such as hospital wastewater - and to implement specific wastewater treatment solutions. Membrane bioreactor (MBR) technology seems to be a suitable pre-treatment approach for the subsequent advanced treatment by high pressure membrane systems such as nanofiltration (NF) and reverse osmosis (RO). This paper is based upon investigations on the first full scale MBR for separate treatment of hospital wastewater in Germany. In this study an NF as well as an RO module for further treatment of the MBR filtrate were tested. The removal efficiencies were assessed using the following target compounds: bezafibrate, bisoprolol, carbamazepine, clarithromycin, ciprofloxacin, diclofenac, ibuprofen, metronidazole, moxifloxacin, telmisartan and tramadol. In summary, the results of this study confirmed that MBR technology followed by an advanced treatment for trace pollutant removal is an adequate approach for specific treatment of hot spot wastewater such as hospital wastewater. In particular, it was shown that - comparing the tested NF and RO - only (a two stage) RO is appropriate to remove pharmaceutical residues from hospital wastewater entirely. The recommended yield of the 2-stage RO is 70% which results in a retentate sidestream of 9%. Our investigations proved that RO is a very efficient treatment approach for elimination of trace pollutants.

KW - Hospital wastewater

KW - Membrane bioreactor

KW - Nanofiltration

KW - Pharmaceutical residues

KW - Reverse osmosis

UR - http://www.scopus.com/inward/record.url?scp=77953462837&partnerID=8YFLogxK