Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

  • M. Rahlves
  • J. Díaz Díaz
  • J. Thommes
  • Omid Majdani
  • B. Roth
  • T. Ortmaier
  • E. Reithmeier

External Research Organisations

  • Hannover Medical School (MHH)
  • Cluster of Excellence Hearing4all
  • Vanderbilt University
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU Erlangen-Nürnberg)
View graph of relations

Details

Original languageEnglish
Title of host publicationThe European Conference on Lasers and Electro-Optics, CLEO_Europe 2013
Publication statusPublished - 2013
EventThe European Conference on Lasers and Electro-Optics, CLEO_Europe 2013 - Munich, Germany
Duration: 12 May 201316 May 2013

Publication series

NameOptics InfoBase Conference Papers
ISSN (electronic)2162-2701

Abstract

Optical techniques are utilized in robot aided surgery as navigation tools to guide surgical instruments. The advantages are a reduction of severe damage during surgery and of post-surgical trauma. A common approach is to place spherical markers inside the operating field, which can be detected by a 3D imaging device, in order to determine the position of the patient with respect to the instrument. Optical coherence tomography (OCT) is not only capable of detecting these kind of artificial landmarks, but also natural features within the operating field and the bone. For example, during insertion of artificial cochlear implants channels have to be drilled inside the temporal bone [1]. Air inclusions in the surrounding bone, known as mastoid cells, can be used as natural landmarks and their position has to determined with high precision (see figure 1 (left)). However, when using optical devices as navigation tool, the optical properties of biological tissue distort the three dimensional data set due to refractive index changes which have to be corrected for navigation. This has been performed in ophthalmology but has not been done so far for bone and similar materials [2].

ASJC Scopus subject areas

Cite this

Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery. / Rahlves, M.; Díaz Díaz, J.; Thommes, J. et al.
The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013. 2013. (Optics InfoBase Conference Papers).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Rahlves, M, Díaz Díaz, J, Thommes, J, Majdani, O, Roth, B, Ortmaier, T & Reithmeier, E 2013, Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery. in The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013. Optics InfoBase Conference Papers, The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013, Munich, Germany, 12 May 2013.
Rahlves, M., Díaz Díaz, J., Thommes, J., Majdani, O., Roth, B., Ortmaier, T., & Reithmeier, E. (2013). Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery. In The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013 (Optics InfoBase Conference Papers).
Rahlves M, Díaz Díaz J, Thommes J, Majdani O, Roth B, Ortmaier T et al. Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery. In The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013. 2013. (Optics InfoBase Conference Papers).
Rahlves, M. ; Díaz Díaz, J. ; Thommes, J. et al. / Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery. The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013. 2013. (Optics InfoBase Conference Papers).
Download
@inproceedings{5cd61e0e17dd43b596f01f1078bca34e,
title = "Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery",
abstract = "Optical techniques are utilized in robot aided surgery as navigation tools to guide surgical instruments. The advantages are a reduction of severe damage during surgery and of post-surgical trauma. A common approach is to place spherical markers inside the operating field, which can be detected by a 3D imaging device, in order to determine the position of the patient with respect to the instrument. Optical coherence tomography (OCT) is not only capable of detecting these kind of artificial landmarks, but also natural features within the operating field and the bone. For example, during insertion of artificial cochlear implants channels have to be drilled inside the temporal bone [1]. Air inclusions in the surrounding bone, known as mastoid cells, can be used as natural landmarks and their position has to determined with high precision (see figure 1 (left)). However, when using optical devices as navigation tool, the optical properties of biological tissue distort the three dimensional data set due to refractive index changes which have to be corrected for navigation. This has been performed in ophthalmology but has not been done so far for bone and similar materials [2].",
author = "M. Rahlves and {D{\'i}az D{\'i}az}, J. and J. Thommes and Omid Majdani and B. Roth and T. Ortmaier and E. Reithmeier",
year = "2013",
language = "English",
isbn = "9781479905942",
series = "Optics InfoBase Conference Papers",
booktitle = "The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013",
note = "The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013 ; Conference date: 12-05-2013 Through 16-05-2013",

}

Download

TY - GEN

T1 - Towards refractive index corrected optical coherence tomography as a navigation tool for bone surgery

AU - Rahlves, M.

AU - Díaz Díaz, J.

AU - Thommes, J.

AU - Majdani, Omid

AU - Roth, B.

AU - Ortmaier, T.

AU - Reithmeier, E.

PY - 2013

Y1 - 2013

N2 - Optical techniques are utilized in robot aided surgery as navigation tools to guide surgical instruments. The advantages are a reduction of severe damage during surgery and of post-surgical trauma. A common approach is to place spherical markers inside the operating field, which can be detected by a 3D imaging device, in order to determine the position of the patient with respect to the instrument. Optical coherence tomography (OCT) is not only capable of detecting these kind of artificial landmarks, but also natural features within the operating field and the bone. For example, during insertion of artificial cochlear implants channels have to be drilled inside the temporal bone [1]. Air inclusions in the surrounding bone, known as mastoid cells, can be used as natural landmarks and their position has to determined with high precision (see figure 1 (left)). However, when using optical devices as navigation tool, the optical properties of biological tissue distort the three dimensional data set due to refractive index changes which have to be corrected for navigation. This has been performed in ophthalmology but has not been done so far for bone and similar materials [2].

AB - Optical techniques are utilized in robot aided surgery as navigation tools to guide surgical instruments. The advantages are a reduction of severe damage during surgery and of post-surgical trauma. A common approach is to place spherical markers inside the operating field, which can be detected by a 3D imaging device, in order to determine the position of the patient with respect to the instrument. Optical coherence tomography (OCT) is not only capable of detecting these kind of artificial landmarks, but also natural features within the operating field and the bone. For example, during insertion of artificial cochlear implants channels have to be drilled inside the temporal bone [1]. Air inclusions in the surrounding bone, known as mastoid cells, can be used as natural landmarks and their position has to determined with high precision (see figure 1 (left)). However, when using optical devices as navigation tool, the optical properties of biological tissue distort the three dimensional data set due to refractive index changes which have to be corrected for navigation. This has been performed in ophthalmology but has not been done so far for bone and similar materials [2].

UR - http://www.scopus.com/inward/record.url?scp=84898758752&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84898758752

SN - 9781479905942

T3 - Optics InfoBase Conference Papers

BT - The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013

T2 - The European Conference on Lasers and Electro-Optics, CLEO_Europe 2013

Y2 - 12 May 2013 through 16 May 2013

ER -

By the same author(s)