Time-variable gravity potential components for optical clock comparisons and the definition of international time scales

Research output: Contribution to journalArticleResearchpeer review

Authors

  • C. Voigt
  • H. Denker
  • L. Timmen

Research Organisations

External Research Organisations

  • Helmholtz Centre Potsdam - German Research Centre for Geosciences (GFZ)
View graph of relations

Details

Original languageEnglish
Pages (from-to)1365-1383
Number of pages19
JournalMETROLOGIA
Volume53
Issue number6
Publication statusPublished - Dec 2016

Abstract

The latest generation of optical atomic clocks is approaching the level of one part in 1018 in terms of frequency stability and uncertainty. For clock comparisons and the definition of international time scales, a relativistic redshift effect of the clock frequencies has to be taken into account at a corresponding uncertainty level of about 0.1 m2 s-2 and 0.01 m in terms of gravity potential and height, respectively. Besides the predominant static part of the gravity potential, temporal variations must be considered in order to avoid systematic frequency shifts. Time-variable gravity potential components induced by tides and non-tidal mass redistributions are investigated with regard to the level of one part in 1018. The magnitudes and dominant time periods of the individual gravity potential contributions are investigated globally and for specific laboratory sites together with the related uncertainty estimates. The basics of the computation methods are presented along with the applied models, data sets and software. Solid Earth tides contribute by far the most dominant signal with a global maximum amplitude of 4.2 m2 s-2 for the potential and a range (maximum-to-minimum) of up to 1.3 and 10.0 m2 s-2 in terms of potential differences between specific laboratories over continental and intercontinental scales, respectively. Amplitudes of the ocean tidal loading potential can amount up to 1.25 m2 s-2, while the range of the potential between specific laboratories is 0.3 and 1.1 m2 s-2 over continental and intercontinental scales, respectively. These are the only two contributors being relevant at a 10-17 level. However, several other time-variable potential effects can particularly affect clock comparisons at the 10-18 level. Besides solid Earth pole tides, these are non-tidal mass redistributions in the atmosphere, the oceans and the continental water storage.

Keywords

    clock comparisons, definition of time scales, gravity potential, optical clocks, relativistic redshift effect

ASJC Scopus subject areas

Cite this

Time-variable gravity potential components for optical clock comparisons and the definition of international time scales. / Voigt, C.; Denker, H.; Timmen, L.
In: METROLOGIA, Vol. 53, No. 6, 12.2016, p. 1365-1383.

Research output: Contribution to journalArticleResearchpeer review

Voigt C, Denker H, Timmen L. Time-variable gravity potential components for optical clock comparisons and the definition of international time scales. METROLOGIA. 2016 Dec;53(6):1365-1383. doi: 10.1088/0026-1394/53/6/1365
Download
@article{986a74fb94cc4a7fac548573e3a98fac,
title = "Time-variable gravity potential components for optical clock comparisons and the definition of international time scales",
abstract = "The latest generation of optical atomic clocks is approaching the level of one part in 1018 in terms of frequency stability and uncertainty. For clock comparisons and the definition of international time scales, a relativistic redshift effect of the clock frequencies has to be taken into account at a corresponding uncertainty level of about 0.1 m2 s-2 and 0.01 m in terms of gravity potential and height, respectively. Besides the predominant static part of the gravity potential, temporal variations must be considered in order to avoid systematic frequency shifts. Time-variable gravity potential components induced by tides and non-tidal mass redistributions are investigated with regard to the level of one part in 1018. The magnitudes and dominant time periods of the individual gravity potential contributions are investigated globally and for specific laboratory sites together with the related uncertainty estimates. The basics of the computation methods are presented along with the applied models, data sets and software. Solid Earth tides contribute by far the most dominant signal with a global maximum amplitude of 4.2 m2 s-2 for the potential and a range (maximum-to-minimum) of up to 1.3 and 10.0 m2 s-2 in terms of potential differences between specific laboratories over continental and intercontinental scales, respectively. Amplitudes of the ocean tidal loading potential can amount up to 1.25 m2 s-2, while the range of the potential between specific laboratories is 0.3 and 1.1 m2 s-2 over continental and intercontinental scales, respectively. These are the only two contributors being relevant at a 10-17 level. However, several other time-variable potential effects can particularly affect clock comparisons at the 10-18 level. Besides solid Earth pole tides, these are non-tidal mass redistributions in the atmosphere, the oceans and the continental water storage.",
keywords = "clock comparisons, definition of time scales, gravity potential, optical clocks, relativistic redshift effect",
author = "C. Voigt and H. Denker and L. Timmen",
note = "Publisher Copyright: {\textcopyright} 2016 BIPM & IOP Publishing Ltd. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.",
year = "2016",
month = dec,
doi = "10.1088/0026-1394/53/6/1365",
language = "English",
volume = "53",
pages = "1365--1383",
journal = "METROLOGIA",
issn = "0026-1394",
publisher = "IOP Publishing Ltd.",
number = "6",

}

Download

TY - JOUR

T1 - Time-variable gravity potential components for optical clock comparisons and the definition of international time scales

AU - Voigt, C.

AU - Denker, H.

AU - Timmen, L.

N1 - Publisher Copyright: © 2016 BIPM & IOP Publishing Ltd. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.

PY - 2016/12

Y1 - 2016/12

N2 - The latest generation of optical atomic clocks is approaching the level of one part in 1018 in terms of frequency stability and uncertainty. For clock comparisons and the definition of international time scales, a relativistic redshift effect of the clock frequencies has to be taken into account at a corresponding uncertainty level of about 0.1 m2 s-2 and 0.01 m in terms of gravity potential and height, respectively. Besides the predominant static part of the gravity potential, temporal variations must be considered in order to avoid systematic frequency shifts. Time-variable gravity potential components induced by tides and non-tidal mass redistributions are investigated with regard to the level of one part in 1018. The magnitudes and dominant time periods of the individual gravity potential contributions are investigated globally and for specific laboratory sites together with the related uncertainty estimates. The basics of the computation methods are presented along with the applied models, data sets and software. Solid Earth tides contribute by far the most dominant signal with a global maximum amplitude of 4.2 m2 s-2 for the potential and a range (maximum-to-minimum) of up to 1.3 and 10.0 m2 s-2 in terms of potential differences between specific laboratories over continental and intercontinental scales, respectively. Amplitudes of the ocean tidal loading potential can amount up to 1.25 m2 s-2, while the range of the potential between specific laboratories is 0.3 and 1.1 m2 s-2 over continental and intercontinental scales, respectively. These are the only two contributors being relevant at a 10-17 level. However, several other time-variable potential effects can particularly affect clock comparisons at the 10-18 level. Besides solid Earth pole tides, these are non-tidal mass redistributions in the atmosphere, the oceans and the continental water storage.

AB - The latest generation of optical atomic clocks is approaching the level of one part in 1018 in terms of frequency stability and uncertainty. For clock comparisons and the definition of international time scales, a relativistic redshift effect of the clock frequencies has to be taken into account at a corresponding uncertainty level of about 0.1 m2 s-2 and 0.01 m in terms of gravity potential and height, respectively. Besides the predominant static part of the gravity potential, temporal variations must be considered in order to avoid systematic frequency shifts. Time-variable gravity potential components induced by tides and non-tidal mass redistributions are investigated with regard to the level of one part in 1018. The magnitudes and dominant time periods of the individual gravity potential contributions are investigated globally and for specific laboratory sites together with the related uncertainty estimates. The basics of the computation methods are presented along with the applied models, data sets and software. Solid Earth tides contribute by far the most dominant signal with a global maximum amplitude of 4.2 m2 s-2 for the potential and a range (maximum-to-minimum) of up to 1.3 and 10.0 m2 s-2 in terms of potential differences between specific laboratories over continental and intercontinental scales, respectively. Amplitudes of the ocean tidal loading potential can amount up to 1.25 m2 s-2, while the range of the potential between specific laboratories is 0.3 and 1.1 m2 s-2 over continental and intercontinental scales, respectively. These are the only two contributors being relevant at a 10-17 level. However, several other time-variable potential effects can particularly affect clock comparisons at the 10-18 level. Besides solid Earth pole tides, these are non-tidal mass redistributions in the atmosphere, the oceans and the continental water storage.

KW - clock comparisons

KW - definition of time scales

KW - gravity potential

KW - optical clocks

KW - relativistic redshift effect

UR - http://www.scopus.com/inward/record.url?scp=85001932748&partnerID=8YFLogxK

U2 - 10.1088/0026-1394/53/6/1365

DO - 10.1088/0026-1394/53/6/1365

M3 - Article

AN - SCOPUS:85001932748

VL - 53

SP - 1365

EP - 1383

JO - METROLOGIA

JF - METROLOGIA

SN - 0026-1394

IS - 6

ER -