Details
Original language | English |
---|---|
Pages (from-to) | e27-e34 |
Journal | Journal of Plastic, Reconstructive and Aesthetic Surgery |
Volume | 69 |
Issue number | 2 |
Publication status | Published - 26 Oct 2015 |
Abstract
SummaryIntroduction We investigated the application of the validated portable Kinect camera for three- and four-dimensional breast assessment in female life models. Method Breast images from six life models were captured using the Kinect camera. Capture was conducted with taking three different arm positions while standing upright: with the arms straight down, straight up to the side at 90° and straight all the way up. Images of the volunteers were superimposed on each other. Digital linear distances between sternal notch and nipple-areola complexes were obtained and compared. The views of plastic and breast surgeons to arm positions were questioned. An example for clinical application was provided. Results Successful capture of images of the female life breast models was achieved. Digital breast measurements at the three different arm positions revealed considerable variation in linear distances measured on the images obtained with the Kinect camera. The dynamic of breast movements could be demonstrated by image overlay and the first ever four-dimensional breast assessment was demonstrated. Fourteen plastic and breast surgeons were found to have nine different opinions regarding their favoured arm positions for breast capture. Even though precision of image sharpness still needs improvement, the images were satisfactory for clinical patient use. The Kinect data were shown to be applicable to surgery planning by designing a planar flap from the 3D mesh. Conclusion The portable and low-cost Kinect camera proved to be easy to use for the first application in life models for three- and four-dimensional breast assessment.
Keywords
- Arm positioning, Breast assessment, Flap planning, Kinect, Objective method, Three-dimensional imaging
ASJC Scopus subject areas
- Medicine(all)
- Surgery
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
In: Journal of Plastic, Reconstructive and Aesthetic Surgery, Vol. 69, No. 2, 26.10.2015, p. e27-e34.
Research output: Contribution to journal › Article › Research › peer review
}
TY - JOUR
T1 - The Kinect Recording System for objective three- and four-dimensional breast assessment with image overlays
AU - Henseler, Helga
AU - Bonkat, Sarah Kim
AU - Vogt, Peter Maria
AU - Rosenhahn, Bodo
PY - 2015/10/26
Y1 - 2015/10/26
N2 - SummaryIntroduction We investigated the application of the validated portable Kinect camera for three- and four-dimensional breast assessment in female life models. Method Breast images from six life models were captured using the Kinect camera. Capture was conducted with taking three different arm positions while standing upright: with the arms straight down, straight up to the side at 90° and straight all the way up. Images of the volunteers were superimposed on each other. Digital linear distances between sternal notch and nipple-areola complexes were obtained and compared. The views of plastic and breast surgeons to arm positions were questioned. An example for clinical application was provided. Results Successful capture of images of the female life breast models was achieved. Digital breast measurements at the three different arm positions revealed considerable variation in linear distances measured on the images obtained with the Kinect camera. The dynamic of breast movements could be demonstrated by image overlay and the first ever four-dimensional breast assessment was demonstrated. Fourteen plastic and breast surgeons were found to have nine different opinions regarding their favoured arm positions for breast capture. Even though precision of image sharpness still needs improvement, the images were satisfactory for clinical patient use. The Kinect data were shown to be applicable to surgery planning by designing a planar flap from the 3D mesh. Conclusion The portable and low-cost Kinect camera proved to be easy to use for the first application in life models for three- and four-dimensional breast assessment.
AB - SummaryIntroduction We investigated the application of the validated portable Kinect camera for three- and four-dimensional breast assessment in female life models. Method Breast images from six life models were captured using the Kinect camera. Capture was conducted with taking three different arm positions while standing upright: with the arms straight down, straight up to the side at 90° and straight all the way up. Images of the volunteers were superimposed on each other. Digital linear distances between sternal notch and nipple-areola complexes were obtained and compared. The views of plastic and breast surgeons to arm positions were questioned. An example for clinical application was provided. Results Successful capture of images of the female life breast models was achieved. Digital breast measurements at the three different arm positions revealed considerable variation in linear distances measured on the images obtained with the Kinect camera. The dynamic of breast movements could be demonstrated by image overlay and the first ever four-dimensional breast assessment was demonstrated. Fourteen plastic and breast surgeons were found to have nine different opinions regarding their favoured arm positions for breast capture. Even though precision of image sharpness still needs improvement, the images were satisfactory for clinical patient use. The Kinect data were shown to be applicable to surgery planning by designing a planar flap from the 3D mesh. Conclusion The portable and low-cost Kinect camera proved to be easy to use for the first application in life models for three- and four-dimensional breast assessment.
KW - Arm positioning
KW - Breast assessment
KW - Flap planning
KW - Kinect
KW - Objective method
KW - Three-dimensional imaging
UR - http://www.scopus.com/inward/record.url?scp=84960363768&partnerID=8YFLogxK
U2 - 10.1016/j.bjps.2015.10.021
DO - 10.1016/j.bjps.2015.10.021
M3 - Article
C2 - 26565080
AN - SCOPUS:84960363768
VL - 69
SP - e27-e34
JO - Journal of Plastic, Reconstructive and Aesthetic Surgery
JF - Journal of Plastic, Reconstructive and Aesthetic Surgery
SN - 1748-6815
IS - 2
ER -