Abstract
Within the Collaborative Research Centre 1153 Tailored Forming a process chain is being developed to manufacture hybrid high performance components made from different materials. The optical geometry characterization of red-hot workpieces directly after the forming process yields diverse advantages, e.g., the documentation of workpiece distortion effects during cooling or the rejection of deficient components in an early manufacturing state. Challenges arise due to the high components temperature directly after forming (approximately 1000°C): The applied structured light method is based on the triangulation principle, which requires homogeneous measurement conditions and a rectilinear expansion of light. This essential precondition is violated when measuring hot objects, as the heat input into the surrounding air leads to an inhomogeneous refractive index field. The authors identified low pressure environments as a promising approach to reduce the magnitude and expansion of the heat induced optical inhomogeneity. To this end, a vacuum chamber has been developed at the Institute of Measurement and Automatic Control. One drawback of a measurement chamber is, that the geometry characterization has to be conducted through a chamber window. The sensors light path is therefore again affected - in this case by the window's discrete increase of refractive index, and also due to the different air density states at sensor location (density at ambient pressure conditions) and measurement object location (density at low pressure conditions). Unlike the heat induced deflection effect, the light path manipulation by the window and the manipulated air density state in the chamber are non-dynamic and constant over time. The reconstruction of 3D geometry points based on a structured light sensor measurement directly depends on the mathematical model of detection and illumination unit. The calibration routine yields the necessary sensor model parameters. The window light refraction complicates this calibration procedure, as the standard pinhole camera model used for entocentric lenses does not comprise enough degrees of freedom to adequately parametrize the pixel-dependent light ray shift induced by thick vacuum windows. Telecentric lenses only map parallel light onto a sensor, therefore the window induced ray shift is constant for all sensor pixels and can be directly reproduced by the so-called affine camera model. In this paper, we present an experimental calibration method, and corresponding calibration data and measurement results for a structured light sensor with and without measurement window. The sensor comprises a telecentric stereo camera pair and an entocentric projector. The calibration of the telecentric cameras is conducted according to the well-known affine camera model. The projector is used as feature generator to solve the correspondence problem between the two cameras. The calibration data illustrates that the window refraction effect is fully reproduced by the affine camera model, allowing a precise geometry characterization of objects recorded through windows. The presented approach is meant to be used with the aforementioned vacuum chamber to enable a geometry characterization of hot objects at low pressure levels.
Keywords
- 3-D measurement, Fringe projection, Light deection, Measurement window, Optical inhomogeneity, Refractive index field, Structured light, Triangulation
ASJC Scopus subject areas
- Materials Science(all)
- Electronic, Optical and Magnetic Materials
- Physics and Astronomy(all)
- Condensed Matter Physics
- Computer Science(all)
- Computer Science Applications
- Mathematics(all)
- Applied Mathematics
- Engineering(all)
- Electrical and Electronic Engineering
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
Optical Measurement Systems for Industrial Inspection XI. ed. / Peter Lehmann; Wolfgang Osten; Armando Albertazzi Goncalves. Vol. 11056 SPIE, 2019. 1105614.
Research output: Chapter in book/report/conference proceeding › Conference contribution › Research › peer review
}
TY - GEN
T1 - Structured light sensor with telecentric stereo camera pair for measurements through vacuum windows
AU - Beermann, Rüdiger
AU - Quentin, Lorenz
AU - Kästner, Markus
AU - Reithmeier, Eduard
N1 - Funding information: The authors would like to thank the German Research Foundation (DFG) for the financial and organisational support of this project, as the presented results were obtained within the Collaborative Research Centre 1153 Process Chain for Manufacturing Hybrid High Performance Components by Tailored Forming.
PY - 2019/6/21
Y1 - 2019/6/21
N2 - Within the Collaborative Research Centre 1153 Tailored Forming a process chain is being developed to manufacture hybrid high performance components made from different materials. The optical geometry characterization of red-hot workpieces directly after the forming process yields diverse advantages, e.g., the documentation of workpiece distortion effects during cooling or the rejection of deficient components in an early manufacturing state. Challenges arise due to the high components temperature directly after forming (approximately 1000°C): The applied structured light method is based on the triangulation principle, which requires homogeneous measurement conditions and a rectilinear expansion of light. This essential precondition is violated when measuring hot objects, as the heat input into the surrounding air leads to an inhomogeneous refractive index field. The authors identified low pressure environments as a promising approach to reduce the magnitude and expansion of the heat induced optical inhomogeneity. To this end, a vacuum chamber has been developed at the Institute of Measurement and Automatic Control. One drawback of a measurement chamber is, that the geometry characterization has to be conducted through a chamber window. The sensors light path is therefore again affected - in this case by the window's discrete increase of refractive index, and also due to the different air density states at sensor location (density at ambient pressure conditions) and measurement object location (density at low pressure conditions). Unlike the heat induced deflection effect, the light path manipulation by the window and the manipulated air density state in the chamber are non-dynamic and constant over time. The reconstruction of 3D geometry points based on a structured light sensor measurement directly depends on the mathematical model of detection and illumination unit. The calibration routine yields the necessary sensor model parameters. The window light refraction complicates this calibration procedure, as the standard pinhole camera model used for entocentric lenses does not comprise enough degrees of freedom to adequately parametrize the pixel-dependent light ray shift induced by thick vacuum windows. Telecentric lenses only map parallel light onto a sensor, therefore the window induced ray shift is constant for all sensor pixels and can be directly reproduced by the so-called affine camera model. In this paper, we present an experimental calibration method, and corresponding calibration data and measurement results for a structured light sensor with and without measurement window. The sensor comprises a telecentric stereo camera pair and an entocentric projector. The calibration of the telecentric cameras is conducted according to the well-known affine camera model. The projector is used as feature generator to solve the correspondence problem between the two cameras. The calibration data illustrates that the window refraction effect is fully reproduced by the affine camera model, allowing a precise geometry characterization of objects recorded through windows. The presented approach is meant to be used with the aforementioned vacuum chamber to enable a geometry characterization of hot objects at low pressure levels.
AB - Within the Collaborative Research Centre 1153 Tailored Forming a process chain is being developed to manufacture hybrid high performance components made from different materials. The optical geometry characterization of red-hot workpieces directly after the forming process yields diverse advantages, e.g., the documentation of workpiece distortion effects during cooling or the rejection of deficient components in an early manufacturing state. Challenges arise due to the high components temperature directly after forming (approximately 1000°C): The applied structured light method is based on the triangulation principle, which requires homogeneous measurement conditions and a rectilinear expansion of light. This essential precondition is violated when measuring hot objects, as the heat input into the surrounding air leads to an inhomogeneous refractive index field. The authors identified low pressure environments as a promising approach to reduce the magnitude and expansion of the heat induced optical inhomogeneity. To this end, a vacuum chamber has been developed at the Institute of Measurement and Automatic Control. One drawback of a measurement chamber is, that the geometry characterization has to be conducted through a chamber window. The sensors light path is therefore again affected - in this case by the window's discrete increase of refractive index, and also due to the different air density states at sensor location (density at ambient pressure conditions) and measurement object location (density at low pressure conditions). Unlike the heat induced deflection effect, the light path manipulation by the window and the manipulated air density state in the chamber are non-dynamic and constant over time. The reconstruction of 3D geometry points based on a structured light sensor measurement directly depends on the mathematical model of detection and illumination unit. The calibration routine yields the necessary sensor model parameters. The window light refraction complicates this calibration procedure, as the standard pinhole camera model used for entocentric lenses does not comprise enough degrees of freedom to adequately parametrize the pixel-dependent light ray shift induced by thick vacuum windows. Telecentric lenses only map parallel light onto a sensor, therefore the window induced ray shift is constant for all sensor pixels and can be directly reproduced by the so-called affine camera model. In this paper, we present an experimental calibration method, and corresponding calibration data and measurement results for a structured light sensor with and without measurement window. The sensor comprises a telecentric stereo camera pair and an entocentric projector. The calibration of the telecentric cameras is conducted according to the well-known affine camera model. The projector is used as feature generator to solve the correspondence problem between the two cameras. The calibration data illustrates that the window refraction effect is fully reproduced by the affine camera model, allowing a precise geometry characterization of objects recorded through windows. The presented approach is meant to be used with the aforementioned vacuum chamber to enable a geometry characterization of hot objects at low pressure levels.
KW - 3-D measurement
KW - Fringe projection
KW - Light deection
KW - Measurement window
KW - Optical inhomogeneity
KW - Refractive index field
KW - Structured light
KW - Triangulation
UR - http://www.scopus.com/inward/record.url?scp=85076698706&partnerID=8YFLogxK
U2 - 10.15488/10276
DO - 10.15488/10276
M3 - Conference contribution
AN - SCOPUS:85076698706
VL - 11056
BT - Optical Measurement Systems for Industrial Inspection XI
A2 - Lehmann, Peter
A2 - Osten, Wolfgang
A2 - Goncalves, Armando Albertazzi
PB - SPIE
T2 - Optical Measurement Systems for Industrial Inspection XI 2019
Y2 - 24 June 2019 through 27 June 2019
ER -