Simulation and experimental investigation of an ultrasound system with cavitation in concentric zone

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Liang Wang
  • Fushi Bai
  • Haoren Feng
  • Jiamei Jin
  • Jens Twiefel

External Research Organisations

  • Nanjing University of Aeronautics and Astronautics
  • Northwestern Polytechnical University
View graph of relations

Details

Original languageEnglish
Article number113880
JournalSensors and Actuators A: Physical
Volume346
Early online date11 Sept 2022
Publication statusPublished - 16 Oct 2022

Abstract

Nowadays, ultrasonic cavitation has been successfully used for the degradation of organic pollutants. However, many sonotrodes employed for wastewater treatment are excited to present a longitudinal vibration mode. Thus, the strongest cavitation generally occurs at the tip end of the sonotrodes or the inner walls of ultrasound baths, resulting in severe erosion of the vibrating metal surface caused by ultrasonic cavitation, even though the sonotrodes are made of titanium alloy. In addition, recontamination is possible due to corrosion of the sonotrode. To avoid the above issues, a novel ultrasound system composed of a cylindrical sonotrode and a Langevin-type transducer, is proposed for generating cavitation only in the concentric zone of the cylindrical sonotrode. The first-order longitudinal vibration and the radial vibration are simultaneously stimulated in the Langevin transducer and the cylindrical sonotrode, respectively, to produce the focused cavitation at the concentric zone of the sonotrode. At first, the finite element simulation is conducted to confirm the planned vibration of the ultrasound system and to compute its sound pressure. Subsequently, the prototype of the proposed ultrasound system is manufactured and assembled for vibration measurements. Finally, experimental investigations are carried out on the ultrasound system prototype. By the aluminum foil experiments, the cavitation bubbles occurred in the center of the cylindrical sonotrode. The erosion area increased with the increase of the working power and processing time. After treating the methyl violet solution by ultrasonic cavitation for 60 min, the methyl violet in the solution is reduced by 60%, which certainly will help the development of an appropriate flow system for dye degradation.

Keywords

    Contamination-free, Methyl violet, Ultrasonic cavitation, Ultrasound system, Wastewater treatment

ASJC Scopus subject areas

Cite this

Simulation and experimental investigation of an ultrasound system with cavitation in concentric zone. / Wang, Liang; Bai, Fushi; Feng, Haoren et al.
In: Sensors and Actuators A: Physical, Vol. 346, 113880, 16.10.2022.

Research output: Contribution to journalArticleResearchpeer review

Wang L, Bai F, Feng H, Jin J, Twiefel J. Simulation and experimental investigation of an ultrasound system with cavitation in concentric zone. Sensors and Actuators A: Physical. 2022 Oct 16;346:113880. Epub 2022 Sept 11. doi: 10.1016/j.sna.2022.113880
Download
@article{f6c40344fcb34a2783d97e596e9308cf,
title = "Simulation and experimental investigation of an ultrasound system with cavitation in concentric zone",
abstract = "Nowadays, ultrasonic cavitation has been successfully used for the degradation of organic pollutants. However, many sonotrodes employed for wastewater treatment are excited to present a longitudinal vibration mode. Thus, the strongest cavitation generally occurs at the tip end of the sonotrodes or the inner walls of ultrasound baths, resulting in severe erosion of the vibrating metal surface caused by ultrasonic cavitation, even though the sonotrodes are made of titanium alloy. In addition, recontamination is possible due to corrosion of the sonotrode. To avoid the above issues, a novel ultrasound system composed of a cylindrical sonotrode and a Langevin-type transducer, is proposed for generating cavitation only in the concentric zone of the cylindrical sonotrode. The first-order longitudinal vibration and the radial vibration are simultaneously stimulated in the Langevin transducer and the cylindrical sonotrode, respectively, to produce the focused cavitation at the concentric zone of the sonotrode. At first, the finite element simulation is conducted to confirm the planned vibration of the ultrasound system and to compute its sound pressure. Subsequently, the prototype of the proposed ultrasound system is manufactured and assembled for vibration measurements. Finally, experimental investigations are carried out on the ultrasound system prototype. By the aluminum foil experiments, the cavitation bubbles occurred in the center of the cylindrical sonotrode. The erosion area increased with the increase of the working power and processing time. After treating the methyl violet solution by ultrasonic cavitation for 60 min, the methyl violet in the solution is reduced by 60%, which certainly will help the development of an appropriate flow system for dye degradation.",
keywords = "Contamination-free, Methyl violet, Ultrasonic cavitation, Ultrasound system, Wastewater treatment",
author = "Liang Wang and Fushi Bai and Haoren Feng and Jiamei Jin and Jens Twiefel",
note = "Funding Information: This research was supported by the National Natural Science Foundation of China (Grant Nos. 51905262 , and U2037603 ), the Natural Science Foundation of Jiangsu Province (Grant No. BK20190398 ), and Postgraduate Research & Practice Innovation Program of Jiangsu Province ( KYCX22–0334 ).",
year = "2022",
month = oct,
day = "16",
doi = "10.1016/j.sna.2022.113880",
language = "English",
volume = "346",
journal = "Sensors and Actuators A: Physical",
issn = "0924-4247",
publisher = "Elsevier",

}

Download

TY - JOUR

T1 - Simulation and experimental investigation of an ultrasound system with cavitation in concentric zone

AU - Wang, Liang

AU - Bai, Fushi

AU - Feng, Haoren

AU - Jin, Jiamei

AU - Twiefel, Jens

N1 - Funding Information: This research was supported by the National Natural Science Foundation of China (Grant Nos. 51905262 , and U2037603 ), the Natural Science Foundation of Jiangsu Province (Grant No. BK20190398 ), and Postgraduate Research & Practice Innovation Program of Jiangsu Province ( KYCX22–0334 ).

PY - 2022/10/16

Y1 - 2022/10/16

N2 - Nowadays, ultrasonic cavitation has been successfully used for the degradation of organic pollutants. However, many sonotrodes employed for wastewater treatment are excited to present a longitudinal vibration mode. Thus, the strongest cavitation generally occurs at the tip end of the sonotrodes or the inner walls of ultrasound baths, resulting in severe erosion of the vibrating metal surface caused by ultrasonic cavitation, even though the sonotrodes are made of titanium alloy. In addition, recontamination is possible due to corrosion of the sonotrode. To avoid the above issues, a novel ultrasound system composed of a cylindrical sonotrode and a Langevin-type transducer, is proposed for generating cavitation only in the concentric zone of the cylindrical sonotrode. The first-order longitudinal vibration and the radial vibration are simultaneously stimulated in the Langevin transducer and the cylindrical sonotrode, respectively, to produce the focused cavitation at the concentric zone of the sonotrode. At first, the finite element simulation is conducted to confirm the planned vibration of the ultrasound system and to compute its sound pressure. Subsequently, the prototype of the proposed ultrasound system is manufactured and assembled for vibration measurements. Finally, experimental investigations are carried out on the ultrasound system prototype. By the aluminum foil experiments, the cavitation bubbles occurred in the center of the cylindrical sonotrode. The erosion area increased with the increase of the working power and processing time. After treating the methyl violet solution by ultrasonic cavitation for 60 min, the methyl violet in the solution is reduced by 60%, which certainly will help the development of an appropriate flow system for dye degradation.

AB - Nowadays, ultrasonic cavitation has been successfully used for the degradation of organic pollutants. However, many sonotrodes employed for wastewater treatment are excited to present a longitudinal vibration mode. Thus, the strongest cavitation generally occurs at the tip end of the sonotrodes or the inner walls of ultrasound baths, resulting in severe erosion of the vibrating metal surface caused by ultrasonic cavitation, even though the sonotrodes are made of titanium alloy. In addition, recontamination is possible due to corrosion of the sonotrode. To avoid the above issues, a novel ultrasound system composed of a cylindrical sonotrode and a Langevin-type transducer, is proposed for generating cavitation only in the concentric zone of the cylindrical sonotrode. The first-order longitudinal vibration and the radial vibration are simultaneously stimulated in the Langevin transducer and the cylindrical sonotrode, respectively, to produce the focused cavitation at the concentric zone of the sonotrode. At first, the finite element simulation is conducted to confirm the planned vibration of the ultrasound system and to compute its sound pressure. Subsequently, the prototype of the proposed ultrasound system is manufactured and assembled for vibration measurements. Finally, experimental investigations are carried out on the ultrasound system prototype. By the aluminum foil experiments, the cavitation bubbles occurred in the center of the cylindrical sonotrode. The erosion area increased with the increase of the working power and processing time. After treating the methyl violet solution by ultrasonic cavitation for 60 min, the methyl violet in the solution is reduced by 60%, which certainly will help the development of an appropriate flow system for dye degradation.

KW - Contamination-free

KW - Methyl violet

KW - Ultrasonic cavitation

KW - Ultrasound system

KW - Wastewater treatment

UR - http://www.scopus.com/inward/record.url?scp=85138204554&partnerID=8YFLogxK

U2 - 10.1016/j.sna.2022.113880

DO - 10.1016/j.sna.2022.113880

M3 - Article

AN - SCOPUS:85138204554

VL - 346

JO - Sensors and Actuators A: Physical

JF - Sensors and Actuators A: Physical

SN - 0924-4247

M1 - 113880

ER -