Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Juan M. Cornejo
  • Johannes Brombacher
  • Julia A. Coenders
  • Moritz Von Boehn
  • Teresa Meiners
  • Malte Niemann
  • Stefan Ulmer
  • Christian Ospelkaus

Research Organisations

External Research Organisations

  • Ulmer Fundamental Symmetries Laboratory
  • University Hospital Düsseldorf
  • National Metrology Institute of Germany (PTB)
View graph of relations

Details

Original languageEnglish
Article number033233
JournalPhysical Review Research
Volume6
Issue number3
Publication statusPublished - 3 Sept 2024

Abstract

Manipulating the motion of individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling sweeping advances in quantum information processing and precision metrology. The key step for motional-state engineering is ground-state cooling. Full motional control also bears great potential to explore another regime of sensitivities for fundamental physics tests in Penning traps. Here we demonstrate the key enabling step by implementing resolved-sideband cooling on the axial mode of a single Be+9 ion in a 5 Tesla cryogenic Penning trap. The system has been developed for the implementation of high-precision antimatter experiments to test the fundamental symmetries of the standard model with the highest accuracy in the baryonic sector. We measure an axial phonon number of n¯z=0.10(4) after cooling and demonstrate that the axial heating rate in our system is compatible with the implementation of quantum logic spectroscopy of (anti-)protons.

ASJC Scopus subject areas

Cite this

Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons. / Cornejo, Juan M.; Brombacher, Johannes; Coenders, Julia A. et al.
In: Physical Review Research, Vol. 6, No. 3, 033233, 03.09.2024.

Research output: Contribution to journalArticleResearchpeer review

Cornejo, JM, Brombacher, J, Coenders, JA, Von Boehn, M, Meiners, T, Niemann, M, Ulmer, S & Ospelkaus, C 2024, 'Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons', Physical Review Research, vol. 6, no. 3, 033233. https://doi.org/10.1103/PhysRevResearch.6.033233
Cornejo, J. M., Brombacher, J., Coenders, J. A., Von Boehn, M., Meiners, T., Niemann, M., Ulmer, S., & Ospelkaus, C. (2024). Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons. Physical Review Research, 6(3), Article 033233. https://doi.org/10.1103/PhysRevResearch.6.033233
Cornejo JM, Brombacher J, Coenders JA, Von Boehn M, Meiners T, Niemann M et al. Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons. Physical Review Research. 2024 Sept 3;6(3):033233. doi: 10.1103/PhysRevResearch.6.033233
Cornejo, Juan M. ; Brombacher, Johannes ; Coenders, Julia A. et al. / Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons. In: Physical Review Research. 2024 ; Vol. 6, No. 3.
Download
@article{9a5860d37b5d4795b0fd7eca4b96fadb,
title = "Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons",
abstract = "Manipulating the motion of individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling sweeping advances in quantum information processing and precision metrology. The key step for motional-state engineering is ground-state cooling. Full motional control also bears great potential to explore another regime of sensitivities for fundamental physics tests in Penning traps. Here we demonstrate the key enabling step by implementing resolved-sideband cooling on the axial mode of a single Be+9 ion in a 5 Tesla cryogenic Penning trap. The system has been developed for the implementation of high-precision antimatter experiments to test the fundamental symmetries of the standard model with the highest accuracy in the baryonic sector. We measure an axial phonon number of n¯z=0.10(4) after cooling and demonstrate that the axial heating rate in our system is compatible with the implementation of quantum logic spectroscopy of (anti-)protons.",
author = "Cornejo, {Juan M.} and Johannes Brombacher and Coenders, {Julia A.} and {Von Boehn}, Moritz and Teresa Meiners and Malte Niemann and Stefan Ulmer and Christian Ospelkaus",
note = "Publisher Copyright: {\textcopyright} 2024 authors. Published by the American Physical Society. Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.",
year = "2024",
month = sep,
day = "3",
doi = "10.1103/PhysRevResearch.6.033233",
language = "English",
volume = "6",
number = "3",

}

Download

TY - JOUR

T1 - Resolved-sideband cooling of a single Be + 9 ion in a cryogenic multi-Penning-trap for discrete symmetry tests with (anti-)protons

AU - Cornejo, Juan M.

AU - Brombacher, Johannes

AU - Coenders, Julia A.

AU - Von Boehn, Moritz

AU - Meiners, Teresa

AU - Niemann, Malte

AU - Ulmer, Stefan

AU - Ospelkaus, Christian

N1 - Publisher Copyright: © 2024 authors. Published by the American Physical Society. Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

PY - 2024/9/3

Y1 - 2024/9/3

N2 - Manipulating the motion of individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling sweeping advances in quantum information processing and precision metrology. The key step for motional-state engineering is ground-state cooling. Full motional control also bears great potential to explore another regime of sensitivities for fundamental physics tests in Penning traps. Here we demonstrate the key enabling step by implementing resolved-sideband cooling on the axial mode of a single Be+9 ion in a 5 Tesla cryogenic Penning trap. The system has been developed for the implementation of high-precision antimatter experiments to test the fundamental symmetries of the standard model with the highest accuracy in the baryonic sector. We measure an axial phonon number of n¯z=0.10(4) after cooling and demonstrate that the axial heating rate in our system is compatible with the implementation of quantum logic spectroscopy of (anti-)protons.

AB - Manipulating the motion of individual trapped ions at the single quantum level has become standard practice in radio-frequency ion traps, enabling sweeping advances in quantum information processing and precision metrology. The key step for motional-state engineering is ground-state cooling. Full motional control also bears great potential to explore another regime of sensitivities for fundamental physics tests in Penning traps. Here we demonstrate the key enabling step by implementing resolved-sideband cooling on the axial mode of a single Be+9 ion in a 5 Tesla cryogenic Penning trap. The system has been developed for the implementation of high-precision antimatter experiments to test the fundamental symmetries of the standard model with the highest accuracy in the baryonic sector. We measure an axial phonon number of n¯z=0.10(4) after cooling and demonstrate that the axial heating rate in our system is compatible with the implementation of quantum logic spectroscopy of (anti-)protons.

UR - http://www.scopus.com/inward/record.url?scp=85203602667&partnerID=8YFLogxK

U2 - 10.1103/PhysRevResearch.6.033233

DO - 10.1103/PhysRevResearch.6.033233

M3 - Article

AN - SCOPUS:85203602667

VL - 6

JO - Physical Review Research

JF - Physical Review Research

SN - 2643-1564

IS - 3

M1 - 033233

ER -

By the same author(s)