Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Christoph Schaefer
  • Martin Lippmann
  • Clara Schindler
  • Michiel Beukers
  • Niels Beijer
  • Moritz Hitzemann
  • Ben van de Kamp
  • Ruud Peters
  • Jaap Knotter
  • Stefan Zimmermann

External Research Organisations

  • Saxion University of Applied Sciences
  • Police Academy of The Netherlands
View graph of relations

Details

Original languageEnglish
Article number112196
Number of pages10
JournalForensic science international
Volume363
Early online date13 Aug 2024
Publication statusE-pub ahead of print - 13 Aug 2024

Abstract

High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a technique for rapid and reliable detection of trace compounds down to ppbV-levels within one second. Compared to classical IMS operating at ambient pressure and providing the ion mobility at low electric fields, HiKE-IMS can also provide the analyte-specific field dependence of the ion mobility and a fragmentation pattern at high reduced electric field strengths. The additional information about the analyte obtained by varying the reduced electric field strength can contribute to reliable detection. Furthermore, the reduced number of ion-molecule reactions at the low operating pressure of 10 – 40 mbar and the shorter reaction times reduce the impact of competing ion-molecule reactions that can cause false negatives. In this work, we employ HiKE-IMS for the analysis of phenyl-2-propanone (P2P) and other precursor chemicals used for synthesis of methamphetamine and amphetamine. The results show that the precursor chemicals exhibit different behavior in HiKE-IMS. Some precursors form a single significant ion species, while others readily form a fragmentation pattern. Nevertheless, all drug precursors can be distinguished from each other, from the reactant ions and from interfering compounds. In particular, the field-dependent ion mobility as an additional separation dimension aids identification, potentially reducing the number of false positive alarms in field applications. Furthermore, the analysis of a seized illicit P2P sample shows that even low levels of P2P can be detected despite the complex background present in the headspace of real samples.

Keywords

    Detection, Drug precursor, High Kinetic Energy Ion Mobility Spectrometry, Ion mobility spectrometry, Synthetic drugs of abuse

ASJC Scopus subject areas

Sustainable Development Goals

Cite this

Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry. / Schaefer, Christoph; Lippmann, Martin; Schindler, Clara et al.
In: Forensic science international, Vol. 363, 112196, 10.2024.

Research output: Contribution to journalArticleResearchpeer review

Schaefer, C, Lippmann, M, Schindler, C, Beukers, M, Beijer, N, Hitzemann, M, van de Kamp, B, Peters, R, Knotter, J & Zimmermann, S 2024, 'Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry', Forensic science international, vol. 363, 112196. https://doi.org/10.1016/j.forsciint.2024.112196
Schaefer, C., Lippmann, M., Schindler, C., Beukers, M., Beijer, N., Hitzemann, M., van de Kamp, B., Peters, R., Knotter, J., & Zimmermann, S. (2024). Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry. Forensic science international, 363, Article 112196. Advance online publication. https://doi.org/10.1016/j.forsciint.2024.112196
Schaefer C, Lippmann M, Schindler C, Beukers M, Beijer N, Hitzemann M et al. Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry. Forensic science international. 2024 Oct;363:112196. Epub 2024 Aug 13. doi: 10.1016/j.forsciint.2024.112196
Download
@article{8abb55c47496410d8eb0d3f1eaf19301,
title = "Pursuing drug laboratories: Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry",
abstract = "High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a technique for rapid and reliable detection of trace compounds down to ppbV-levels within one second. Compared to classical IMS operating at ambient pressure and providing the ion mobility at low electric fields, HiKE-IMS can also provide the analyte-specific field dependence of the ion mobility and a fragmentation pattern at high reduced electric field strengths. The additional information about the analyte obtained by varying the reduced electric field strength can contribute to reliable detection. Furthermore, the reduced number of ion-molecule reactions at the low operating pressure of 10 – 40 mbar and the shorter reaction times reduce the impact of competing ion-molecule reactions that can cause false negatives. In this work, we employ HiKE-IMS for the analysis of phenyl-2-propanone (P2P) and other precursor chemicals used for synthesis of methamphetamine and amphetamine. The results show that the precursor chemicals exhibit different behavior in HiKE-IMS. Some precursors form a single significant ion species, while others readily form a fragmentation pattern. Nevertheless, all drug precursors can be distinguished from each other, from the reactant ions and from interfering compounds. In particular, the field-dependent ion mobility as an additional separation dimension aids identification, potentially reducing the number of false positive alarms in field applications. Furthermore, the analysis of a seized illicit P2P sample shows that even low levels of P2P can be detected despite the complex background present in the headspace of real samples.",
keywords = "Detection, Drug precursor, High Kinetic Energy Ion Mobility Spectrometry, Ion mobility spectrometry, Synthetic drugs of abuse",
author = "Christoph Schaefer and Martin Lippmann and Clara Schindler and Michiel Beukers and Niels Beijer and Moritz Hitzemann and {van de Kamp}, Ben and Ruud Peters and Jaap Knotter and Stefan Zimmermann",
note = "Publisher Copyright: {\textcopyright} 2024 The Authors",
year = "2024",
month = aug,
day = "13",
doi = "10.1016/j.forsciint.2024.112196",
language = "English",
volume = "363",
journal = "Forensic science international",
issn = "0379-0738",
publisher = "Elsevier Ireland Ltd",

}

Download

TY - JOUR

T1 - Pursuing drug laboratories

T2 - Analysis of drug precursors with High Kinetic Energy Ion Mobility Spectrometry

AU - Schaefer, Christoph

AU - Lippmann, Martin

AU - Schindler, Clara

AU - Beukers, Michiel

AU - Beijer, Niels

AU - Hitzemann, Moritz

AU - van de Kamp, Ben

AU - Peters, Ruud

AU - Knotter, Jaap

AU - Zimmermann, Stefan

N1 - Publisher Copyright: © 2024 The Authors

PY - 2024/8/13

Y1 - 2024/8/13

N2 - High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a technique for rapid and reliable detection of trace compounds down to ppbV-levels within one second. Compared to classical IMS operating at ambient pressure and providing the ion mobility at low electric fields, HiKE-IMS can also provide the analyte-specific field dependence of the ion mobility and a fragmentation pattern at high reduced electric field strengths. The additional information about the analyte obtained by varying the reduced electric field strength can contribute to reliable detection. Furthermore, the reduced number of ion-molecule reactions at the low operating pressure of 10 – 40 mbar and the shorter reaction times reduce the impact of competing ion-molecule reactions that can cause false negatives. In this work, we employ HiKE-IMS for the analysis of phenyl-2-propanone (P2P) and other precursor chemicals used for synthesis of methamphetamine and amphetamine. The results show that the precursor chemicals exhibit different behavior in HiKE-IMS. Some precursors form a single significant ion species, while others readily form a fragmentation pattern. Nevertheless, all drug precursors can be distinguished from each other, from the reactant ions and from interfering compounds. In particular, the field-dependent ion mobility as an additional separation dimension aids identification, potentially reducing the number of false positive alarms in field applications. Furthermore, the analysis of a seized illicit P2P sample shows that even low levels of P2P can be detected despite the complex background present in the headspace of real samples.

AB - High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a technique for rapid and reliable detection of trace compounds down to ppbV-levels within one second. Compared to classical IMS operating at ambient pressure and providing the ion mobility at low electric fields, HiKE-IMS can also provide the analyte-specific field dependence of the ion mobility and a fragmentation pattern at high reduced electric field strengths. The additional information about the analyte obtained by varying the reduced electric field strength can contribute to reliable detection. Furthermore, the reduced number of ion-molecule reactions at the low operating pressure of 10 – 40 mbar and the shorter reaction times reduce the impact of competing ion-molecule reactions that can cause false negatives. In this work, we employ HiKE-IMS for the analysis of phenyl-2-propanone (P2P) and other precursor chemicals used for synthesis of methamphetamine and amphetamine. The results show that the precursor chemicals exhibit different behavior in HiKE-IMS. Some precursors form a single significant ion species, while others readily form a fragmentation pattern. Nevertheless, all drug precursors can be distinguished from each other, from the reactant ions and from interfering compounds. In particular, the field-dependent ion mobility as an additional separation dimension aids identification, potentially reducing the number of false positive alarms in field applications. Furthermore, the analysis of a seized illicit P2P sample shows that even low levels of P2P can be detected despite the complex background present in the headspace of real samples.

KW - Detection

KW - Drug precursor

KW - High Kinetic Energy Ion Mobility Spectrometry

KW - Ion mobility spectrometry

KW - Synthetic drugs of abuse

UR - http://www.scopus.com/inward/record.url?scp=85201399070&partnerID=8YFLogxK

U2 - 10.1016/j.forsciint.2024.112196

DO - 10.1016/j.forsciint.2024.112196

M3 - Article

C2 - 39151243

AN - SCOPUS:85201399070

VL - 363

JO - Forensic science international

JF - Forensic science international

SN - 0379-0738

M1 - 112196

ER -

By the same author(s)