Abstract

I on mobility spectrometry is a well-known technique used to analyze trace gases in ambient air. Typically, it works by employing a radioactive source to provide electrons with high energy to ionize the ana-lytes in a series of chemical reactions. During the past ten years non-radioactive sources have been one of the subjects of interest in ion mobility spectrometry, initially in order to replace radioactive sources as a result of general security and regulatory concerns. Among these non-radioactive sources especially pulsed sources have recently been shown to additionally improve the analytic information provided by ion mobility spectrometers. In this review we will describe the progress regarding the application of pulsed non-radioactive electron sources in ion mobility spectrometry and show the recent analytical advances that have been achieved by using pulsed electron beams.

Keywords

    Analytical information, Ion mobility spectro-metry, Non-radioactive electron sources, Pulsed electron beams

ASJC Scopus subject areas

Cite this

Pulsed electron beams in ion mobility spectrometry. / Baether, Wolfgang; Zimmermann, Stefan; Gunzer, Frank.
In: Reviews in Analytical Chemistry, Vol. 31, No. 3-4, 26.07.2012, p. 139-152.

Research output: Contribution to journalReview articleResearchpeer review

Baether W, Zimmermann S, Gunzer F. Pulsed electron beams in ion mobility spectrometry. Reviews in Analytical Chemistry. 2012 Jul 26;31(3-4):139-152. doi: 10.1515/revac-2012-0018, 10.15488/179
Baether, Wolfgang ; Zimmermann, Stefan ; Gunzer, Frank. / Pulsed electron beams in ion mobility spectrometry. In: Reviews in Analytical Chemistry. 2012 ; Vol. 31, No. 3-4. pp. 139-152.
Download
@article{5449848b517d49c48e3dd1dc35ffe9ed,
title = "Pulsed electron beams in ion mobility spectrometry",
abstract = "I on mobility spectrometry is a well-known technique used to analyze trace gases in ambient air. Typically, it works by employing a radioactive source to provide electrons with high energy to ionize the ana-lytes in a series of chemical reactions. During the past ten years non-radioactive sources have been one of the subjects of interest in ion mobility spectrometry, initially in order to replace radioactive sources as a result of general security and regulatory concerns. Among these non-radioactive sources especially pulsed sources have recently been shown to additionally improve the analytic information provided by ion mobility spectrometers. In this review we will describe the progress regarding the application of pulsed non-radioactive electron sources in ion mobility spectrometry and show the recent analytical advances that have been achieved by using pulsed electron beams.",
keywords = "Analytical information, Ion mobility spectro-metry, Non-radioactive electron sources, Pulsed electron beams",
author = "Wolfgang Baether and Stefan Zimmermann and Frank Gunzer",
year = "2012",
month = jul,
day = "26",
doi = "10.1515/revac-2012-0018",
language = "English",
volume = "31",
pages = "139--152",
journal = "Reviews in Analytical Chemistry",
issn = "0793-0135",
publisher = "Walter de Gruyter GmbH",
number = "3-4",

}

Download

TY - JOUR

T1 - Pulsed electron beams in ion mobility spectrometry

AU - Baether, Wolfgang

AU - Zimmermann, Stefan

AU - Gunzer, Frank

PY - 2012/7/26

Y1 - 2012/7/26

N2 - I on mobility spectrometry is a well-known technique used to analyze trace gases in ambient air. Typically, it works by employing a radioactive source to provide electrons with high energy to ionize the ana-lytes in a series of chemical reactions. During the past ten years non-radioactive sources have been one of the subjects of interest in ion mobility spectrometry, initially in order to replace radioactive sources as a result of general security and regulatory concerns. Among these non-radioactive sources especially pulsed sources have recently been shown to additionally improve the analytic information provided by ion mobility spectrometers. In this review we will describe the progress regarding the application of pulsed non-radioactive electron sources in ion mobility spectrometry and show the recent analytical advances that have been achieved by using pulsed electron beams.

AB - I on mobility spectrometry is a well-known technique used to analyze trace gases in ambient air. Typically, it works by employing a radioactive source to provide electrons with high energy to ionize the ana-lytes in a series of chemical reactions. During the past ten years non-radioactive sources have been one of the subjects of interest in ion mobility spectrometry, initially in order to replace radioactive sources as a result of general security and regulatory concerns. Among these non-radioactive sources especially pulsed sources have recently been shown to additionally improve the analytic information provided by ion mobility spectrometers. In this review we will describe the progress regarding the application of pulsed non-radioactive electron sources in ion mobility spectrometry and show the recent analytical advances that have been achieved by using pulsed electron beams.

KW - Analytical information

KW - Ion mobility spectro-metry

KW - Non-radioactive electron sources

KW - Pulsed electron beams

UR - http://www.scopus.com/inward/record.url?scp=84870220039&partnerID=8YFLogxK

U2 - 10.1515/revac-2012-0018

DO - 10.1515/revac-2012-0018

M3 - Review article

AN - SCOPUS:84870220039

VL - 31

SP - 139

EP - 152

JO - Reviews in Analytical Chemistry

JF - Reviews in Analytical Chemistry

SN - 0793-0135

IS - 3-4

ER -