Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

  • L. Prielozny
  • J. P. Kobler
  • T. Ortmaier
  • J. Lexow
  • T. Rau
  • T. Lenarz
  • O. Majdani

Research Organisations

External Research Organisations

  • Hannover Medical School (MHH)
View graph of relations

Details

Original languageEnglish
Title of host publicationCURAC Annual Meeting
Subtitle of host publicationProceedings of the CURAC (Computer- und Roboterassistierte Chirurgie) Annual Meeting
Pages77-80
Number of pages4
Publication statusPublished - 2013
EventAnnual Meeting of CURAC (Computer-und Roboterassistierte Chirurgie), CURAC 2013 - Innsbruck, Austria
Duration: 28 Nov 201330 Nov 2013

Publication series

NameCEUR Workshop Proceedings
PublisherCEUR Workshop Proceedings
Volume1477
ISSN (Print)1613-0073

Abstract

Pull out tests for bone anchors used in surgical robotics were performed to prove the strength of the bone anchor - bone combination. Forces and displacement were measured to evaluate the suitability of the bone anchors as a connection between a surgical robot and bone. A universal experimental setup was designed to conduct the pull out tests. As specimens, human cranial cadaver bone, porcine cadaver hip bone and solid rigid polyurethane foams were chosen. The bone anchors were manually screwed into the specimens and then pulled out using the experimental setup. Mechanical similarities between natural bone and solid rigid polyurethane foams were found. The results suggest that the bone anchors are suitable for the attachment of surgical robotics.

Keywords

    Bone anchor, Bone screw, Cochlear implantation, Force measurement, Minimal invasive, Parallel kinematic, Pull out tests

ASJC Scopus subject areas

Cite this

Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery. / Prielozny, L.; Kobler, J. P.; Ortmaier, T. et al.
CURAC Annual Meeting: Proceedings of the CURAC (Computer- und Roboterassistierte Chirurgie) Annual Meeting. 2013. p. 77-80 (CEUR Workshop Proceedings; Vol. 1477).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Prielozny, L, Kobler, JP, Ortmaier, T, Lexow, J, Rau, T, Lenarz, T & Majdani, O 2013, Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery. in CURAC Annual Meeting: Proceedings of the CURAC (Computer- und Roboterassistierte Chirurgie) Annual Meeting. CEUR Workshop Proceedings, vol. 1477, pp. 77-80, Annual Meeting of CURAC (Computer-und Roboterassistierte Chirurgie), CURAC 2013, Innsbruck, Austria, 28 Nov 2013. <https://ceur-ws.org/Vol-1477/Proceedings_CURAC_2013_Paper_19.pdf>
Prielozny, L., Kobler, J. P., Ortmaier, T., Lexow, J., Rau, T., Lenarz, T., & Majdani, O. (2013). Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery. In CURAC Annual Meeting: Proceedings of the CURAC (Computer- und Roboterassistierte Chirurgie) Annual Meeting (pp. 77-80). (CEUR Workshop Proceedings; Vol. 1477). https://ceur-ws.org/Vol-1477/Proceedings_CURAC_2013_Paper_19.pdf
Prielozny L, Kobler JP, Ortmaier T, Lexow J, Rau T, Lenarz T et al. Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery. In CURAC Annual Meeting: Proceedings of the CURAC (Computer- und Roboterassistierte Chirurgie) Annual Meeting. 2013. p. 77-80. (CEUR Workshop Proceedings).
Prielozny, L. ; Kobler, J. P. ; Ortmaier, T. et al. / Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery. CURAC Annual Meeting: Proceedings of the CURAC (Computer- und Roboterassistierte Chirurgie) Annual Meeting. 2013. pp. 77-80 (CEUR Workshop Proceedings).
Download
@inproceedings{df6afe2b493140f4aae6ee006fc41326,
title = "Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery",
abstract = "Pull out tests for bone anchors used in surgical robotics were performed to prove the strength of the bone anchor - bone combination. Forces and displacement were measured to evaluate the suitability of the bone anchors as a connection between a surgical robot and bone. A universal experimental setup was designed to conduct the pull out tests. As specimens, human cranial cadaver bone, porcine cadaver hip bone and solid rigid polyurethane foams were chosen. The bone anchors were manually screwed into the specimens and then pulled out using the experimental setup. Mechanical similarities between natural bone and solid rigid polyurethane foams were found. The results suggest that the bone anchors are suitable for the attachment of surgical robotics.",
keywords = "Bone anchor, Bone screw, Cochlear implantation, Force measurement, Minimal invasive, Parallel kinematic, Pull out tests",
author = "L. Prielozny and Kobler, {J. P.} and T. Ortmaier and J. Lexow and T. Rau and T. Lenarz and O. Majdani",
year = "2013",
language = "English",
series = "CEUR Workshop Proceedings",
publisher = "CEUR Workshop Proceedings",
pages = "77--80",
booktitle = "CURAC Annual Meeting",
note = "Annual Meeting of CURAC (Computer-und Roboterassistierte Chirurgie), CURAC 2013 ; Conference date: 28-11-2013 Through 30-11-2013",

}

Download

TY - GEN

T1 - Pull-out tests on bone anchors of a head-Mounted parallel kinematic robot for skull surgery

AU - Prielozny, L.

AU - Kobler, J. P.

AU - Ortmaier, T.

AU - Lexow, J.

AU - Rau, T.

AU - Lenarz, T.

AU - Majdani, O.

PY - 2013

Y1 - 2013

N2 - Pull out tests for bone anchors used in surgical robotics were performed to prove the strength of the bone anchor - bone combination. Forces and displacement were measured to evaluate the suitability of the bone anchors as a connection between a surgical robot and bone. A universal experimental setup was designed to conduct the pull out tests. As specimens, human cranial cadaver bone, porcine cadaver hip bone and solid rigid polyurethane foams were chosen. The bone anchors were manually screwed into the specimens and then pulled out using the experimental setup. Mechanical similarities between natural bone and solid rigid polyurethane foams were found. The results suggest that the bone anchors are suitable for the attachment of surgical robotics.

AB - Pull out tests for bone anchors used in surgical robotics were performed to prove the strength of the bone anchor - bone combination. Forces and displacement were measured to evaluate the suitability of the bone anchors as a connection between a surgical robot and bone. A universal experimental setup was designed to conduct the pull out tests. As specimens, human cranial cadaver bone, porcine cadaver hip bone and solid rigid polyurethane foams were chosen. The bone anchors were manually screwed into the specimens and then pulled out using the experimental setup. Mechanical similarities between natural bone and solid rigid polyurethane foams were found. The results suggest that the bone anchors are suitable for the attachment of surgical robotics.

KW - Bone anchor

KW - Bone screw

KW - Cochlear implantation

KW - Force measurement

KW - Minimal invasive

KW - Parallel kinematic

KW - Pull out tests

UR - http://www.scopus.com/inward/record.url?scp=84983138414&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84983138414

T3 - CEUR Workshop Proceedings

SP - 77

EP - 80

BT - CURAC Annual Meeting

T2 - Annual Meeting of CURAC (Computer-und Roboterassistierte Chirurgie), CURAC 2013

Y2 - 28 November 2013 through 30 November 2013

ER -