Details
Original language | English |
---|---|
Pages (from-to) | 168-171 |
Journal | Conference Record of IEEE International Symposium on Electrical Insulation |
Publication status | Published - 2000 |
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range. / Kaindl, A.; Nowak, S.; Koschnitzki, T. et al.
In: Conference Record of IEEE International Symposium on Electrical Insulation, 2000, p. 168-171.
In: Conference Record of IEEE International Symposium on Electrical Insulation, 2000, p. 168-171.
Research output: Contribution to journal › Conference article › Research › peer review
Kaindl, A, Nowak, S, Koschnitzki, T & Borsi, H 2000, 'Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range', Conference Record of IEEE International Symposium on Electrical Insulation, pp. 168-171. https://doi.org/10.1109/ELINSL.2000.845481
Kaindl, A., Nowak, S., Koschnitzki, T., & Borsi, H. (2000). Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range. Conference Record of IEEE International Symposium on Electrical Insulation, 168-171. https://doi.org/10.1109/ELINSL.2000.845481
Kaindl A, Nowak S, Koschnitzki T, Borsi H. Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range. Conference Record of IEEE International Symposium on Electrical Insulation. 2000;168-171. doi: 10.1109/ELINSL.2000.845481
Download
@article{c8f442bfbde142a090be60baf57ce695,
title = "Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range",
author = "A. Kaindl and S. Nowak and T. Koschnitzki and H. Borsi",
year = "2000",
doi = "10.1109/ELINSL.2000.845481",
language = "English",
pages = "168--171",
}
Download
TY - JOUR
T1 - Practical application of partial discharge measurements at epoxy impregnated coils for analyzing signal noise in the radio frequency range
AU - Kaindl, A.
AU - Nowak, S.
AU - Koschnitzki, T.
AU - Borsi, H.
PY - 2000
Y1 - 2000
U2 - 10.1109/ELINSL.2000.845481
DO - 10.1109/ELINSL.2000.845481
M3 - Conference article
SP - 168
EP - 171
JO - Conference Record of IEEE International Symposium on Electrical Insulation
JF - Conference Record of IEEE International Symposium on Electrical Insulation
SN - 0164-2006
ER -