Plate-height model of ion mobility-mass spectrometry

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Márkó Grabarics
  • Maike Lettow
  • Ansgar T. Kirk
  • Gert Von Helden
  • Tim J. Causon
  • Kevin Pagel

External Research Organisations

  • Freie Universität Berlin (FU Berlin)
  • Fritz Haber Institute of the Max Planck Society (FHI)
  • University of Natural Resources and Applied Life Sciences (BOKU)
View graph of relations

Details

Original languageEnglish
Pages (from-to)6313-6333
Number of pages21
JournalThe Analyst
Volume145
Issue number19
Early online date8 Jul 2020
Publication statusPublished - 7 Oct 2020

Abstract

In the past decade, ion mobility spectrometry (IMS) in combination with mass spectrometry (IM-MS) became a widely employed technique for the separation and structural characterization of ionic species in the gas phase. Similarly to chromatography, where studies on the mechanism of band broadening and adequate plate-height equations have been aiding method development and promoting advancements in column technology, a suitable resolving power theory of drift tube ion mobility-mass spectrometry (DTIM-MS) is essential to stimulate further progress in this emerging field of separation science. In the present study, therefore, we explore dispersion processes in detail and present a plate-height model of ion mobility-mass spectrometry. We quantify the effects of five major dispersion processes that contribute to zone broadening and determine the resolving power in DTIM-MS: Diffusion, Coulomb repulsion, electric field inhomogeneities, the finite initial spread of the ion cloud and dispersion outside the mobility cell. A solution is provided to account for the nonuniform separation field in IM-MS in the presence of multiple compartments. The equations-derived from first principles-serve as the basis for formulating an expression that is similar in nature to van Deemter's plate-height equation for chromatography. A comprehensive set of experiments was performed on a custom-built DTIM-MS instrument to evaluate the accuracy of the plate-height model, resulting in satisfactory agreement between experiment and theory. Building on these findings, the plate-height equation was employed to explore the influence of drift gas pressure, injection pulse-width and the mobility of ions on resolving power from a theoretical point of view. Our findings may aid instrument design and development in the future, as well as the optimization of measurement conditions to improve ion mobility separations. By employing the plate-height concept and the general formalism of differential migration processes to describe zone spreading in IM-MS, we aim to find a common ground between this emerging method and such well-established techniques as HPLC or CZE. We also hope that the work presented here will facilitate a broader acceptance of IMS as a separation method of great potential by the communities of chromatography and electrophoresis, as well as that of mass spectrometry. This journal is

ASJC Scopus subject areas

Cite this

Plate-height model of ion mobility-mass spectrometry. / Grabarics, Márkó; Lettow, Maike; Kirk, Ansgar T. et al.
In: The Analyst, Vol. 145, No. 19, 07.10.2020, p. 6313-6333.

Research output: Contribution to journalArticleResearchpeer review

Grabarics, M, Lettow, M, Kirk, AT, Von Helden, G, Causon, TJ & Pagel, K 2020, 'Plate-height model of ion mobility-mass spectrometry', The Analyst, vol. 145, no. 19, pp. 6313-6333. https://doi.org/10.1039/d0an00433b
Grabarics, M., Lettow, M., Kirk, A. T., Von Helden, G., Causon, T. J., & Pagel, K. (2020). Plate-height model of ion mobility-mass spectrometry. The Analyst, 145(19), 6313-6333. https://doi.org/10.1039/d0an00433b
Grabarics M, Lettow M, Kirk AT, Von Helden G, Causon TJ, Pagel K. Plate-height model of ion mobility-mass spectrometry. The Analyst. 2020 Oct 7;145(19):6313-6333. Epub 2020 Jul 8. doi: 10.1039/d0an00433b
Grabarics, Márkó ; Lettow, Maike ; Kirk, Ansgar T. et al. / Plate-height model of ion mobility-mass spectrometry. In: The Analyst. 2020 ; Vol. 145, No. 19. pp. 6313-6333.
Download
@article{d660d521de0f439bbba393103c9d1073,
title = "Plate-height model of ion mobility-mass spectrometry",
abstract = "In the past decade, ion mobility spectrometry (IMS) in combination with mass spectrometry (IM-MS) became a widely employed technique for the separation and structural characterization of ionic species in the gas phase. Similarly to chromatography, where studies on the mechanism of band broadening and adequate plate-height equations have been aiding method development and promoting advancements in column technology, a suitable resolving power theory of drift tube ion mobility-mass spectrometry (DTIM-MS) is essential to stimulate further progress in this emerging field of separation science. In the present study, therefore, we explore dispersion processes in detail and present a plate-height model of ion mobility-mass spectrometry. We quantify the effects of five major dispersion processes that contribute to zone broadening and determine the resolving power in DTIM-MS: Diffusion, Coulomb repulsion, electric field inhomogeneities, the finite initial spread of the ion cloud and dispersion outside the mobility cell. A solution is provided to account for the nonuniform separation field in IM-MS in the presence of multiple compartments. The equations-derived from first principles-serve as the basis for formulating an expression that is similar in nature to van Deemter's plate-height equation for chromatography. A comprehensive set of experiments was performed on a custom-built DTIM-MS instrument to evaluate the accuracy of the plate-height model, resulting in satisfactory agreement between experiment and theory. Building on these findings, the plate-height equation was employed to explore the influence of drift gas pressure, injection pulse-width and the mobility of ions on resolving power from a theoretical point of view. Our findings may aid instrument design and development in the future, as well as the optimization of measurement conditions to improve ion mobility separations. By employing the plate-height concept and the general formalism of differential migration processes to describe zone spreading in IM-MS, we aim to find a common ground between this emerging method and such well-established techniques as HPLC or CZE. We also hope that the work presented here will facilitate a broader acceptance of IMS as a separation method of great potential by the communities of chromatography and electrophoresis, as well as that of mass spectrometry. This journal is ",
author = "M{\'a}rk{\'o} Grabarics and Maike Lettow and Kirk, {Ansgar T.} and {Von Helden}, Gert and Causon, {Tim J.} and Kevin Pagel",
note = "Funding information: The authors gratefully acknowledge financial support from the Freie Universit{\"a}t Berlin and the Max Planck Society. This research was funded by the German Research Foundation (FOR2177/P02). Open Access funding provided by the Max Planck Society.",
year = "2020",
month = oct,
day = "7",
doi = "10.1039/d0an00433b",
language = "English",
volume = "145",
pages = "6313--6333",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "19",

}

Download

TY - JOUR

T1 - Plate-height model of ion mobility-mass spectrometry

AU - Grabarics, Márkó

AU - Lettow, Maike

AU - Kirk, Ansgar T.

AU - Von Helden, Gert

AU - Causon, Tim J.

AU - Pagel, Kevin

N1 - Funding information: The authors gratefully acknowledge financial support from the Freie Universität Berlin and the Max Planck Society. This research was funded by the German Research Foundation (FOR2177/P02). Open Access funding provided by the Max Planck Society.

PY - 2020/10/7

Y1 - 2020/10/7

N2 - In the past decade, ion mobility spectrometry (IMS) in combination with mass spectrometry (IM-MS) became a widely employed technique for the separation and structural characterization of ionic species in the gas phase. Similarly to chromatography, where studies on the mechanism of band broadening and adequate plate-height equations have been aiding method development and promoting advancements in column technology, a suitable resolving power theory of drift tube ion mobility-mass spectrometry (DTIM-MS) is essential to stimulate further progress in this emerging field of separation science. In the present study, therefore, we explore dispersion processes in detail and present a plate-height model of ion mobility-mass spectrometry. We quantify the effects of five major dispersion processes that contribute to zone broadening and determine the resolving power in DTIM-MS: Diffusion, Coulomb repulsion, electric field inhomogeneities, the finite initial spread of the ion cloud and dispersion outside the mobility cell. A solution is provided to account for the nonuniform separation field in IM-MS in the presence of multiple compartments. The equations-derived from first principles-serve as the basis for formulating an expression that is similar in nature to van Deemter's plate-height equation for chromatography. A comprehensive set of experiments was performed on a custom-built DTIM-MS instrument to evaluate the accuracy of the plate-height model, resulting in satisfactory agreement between experiment and theory. Building on these findings, the plate-height equation was employed to explore the influence of drift gas pressure, injection pulse-width and the mobility of ions on resolving power from a theoretical point of view. Our findings may aid instrument design and development in the future, as well as the optimization of measurement conditions to improve ion mobility separations. By employing the plate-height concept and the general formalism of differential migration processes to describe zone spreading in IM-MS, we aim to find a common ground between this emerging method and such well-established techniques as HPLC or CZE. We also hope that the work presented here will facilitate a broader acceptance of IMS as a separation method of great potential by the communities of chromatography and electrophoresis, as well as that of mass spectrometry. This journal is

AB - In the past decade, ion mobility spectrometry (IMS) in combination with mass spectrometry (IM-MS) became a widely employed technique for the separation and structural characterization of ionic species in the gas phase. Similarly to chromatography, where studies on the mechanism of band broadening and adequate plate-height equations have been aiding method development and promoting advancements in column technology, a suitable resolving power theory of drift tube ion mobility-mass spectrometry (DTIM-MS) is essential to stimulate further progress in this emerging field of separation science. In the present study, therefore, we explore dispersion processes in detail and present a plate-height model of ion mobility-mass spectrometry. We quantify the effects of five major dispersion processes that contribute to zone broadening and determine the resolving power in DTIM-MS: Diffusion, Coulomb repulsion, electric field inhomogeneities, the finite initial spread of the ion cloud and dispersion outside the mobility cell. A solution is provided to account for the nonuniform separation field in IM-MS in the presence of multiple compartments. The equations-derived from first principles-serve as the basis for formulating an expression that is similar in nature to van Deemter's plate-height equation for chromatography. A comprehensive set of experiments was performed on a custom-built DTIM-MS instrument to evaluate the accuracy of the plate-height model, resulting in satisfactory agreement between experiment and theory. Building on these findings, the plate-height equation was employed to explore the influence of drift gas pressure, injection pulse-width and the mobility of ions on resolving power from a theoretical point of view. Our findings may aid instrument design and development in the future, as well as the optimization of measurement conditions to improve ion mobility separations. By employing the plate-height concept and the general formalism of differential migration processes to describe zone spreading in IM-MS, we aim to find a common ground between this emerging method and such well-established techniques as HPLC or CZE. We also hope that the work presented here will facilitate a broader acceptance of IMS as a separation method of great potential by the communities of chromatography and electrophoresis, as well as that of mass spectrometry. This journal is

UR - http://www.scopus.com/inward/record.url?scp=85091806399&partnerID=8YFLogxK

U2 - 10.1039/d0an00433b

DO - 10.1039/d0an00433b

M3 - Article

C2 - 32716422

AN - SCOPUS:85091806399

VL - 145

SP - 6313

EP - 6333

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 19

ER -