Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor

Research output: Contribution to conferencePaperResearchpeer review

Authors

  • Axel Fischer
  • Walter Riess
  • Joerg R. Seume
View graph of relations

Details

Original languageEnglish
Pages429-435
Number of pages7
Publication statusPublished - 2009
Event2003 ASME Turbo Expo - Atlanta, GA, United States
Duration: 16 Jun 200319 Jun 2003

Conference

Conference2003 ASME Turbo Expo
Country/TerritoryUnited States
CityAtlanta, GA
Period16 Jun 200319 Jun 2003

Abstract

The FVV-sponsored-Project "Bow Blading" (c.f. acknowledgments) at the Turbomachinery Laboratory of the University of Hannover addresses the effect of strongly bowed stator vanes on the flow field in an 4-stage high speed axial compressor with controlled diffusion airfoil (CDA) blading. The compressor is equipped with more strongly bowed vanes than have previously been reported in the literature. The performance map of the present compressor is being investigated experimentally and numerically. The results show that the pressure ratio and the efficiency at the design point and at the choke limit are reduced by the increase in friction losses on the surface of the bowed vanes, whose surface area is greater than that of the reference (CDA) vanes. The mass flow at the choke limit decreases for the same reason. Because of the change in the radial distribution of axial velocity, pressure rise shifts from stage 3 to stage 4 between the choke limit and maximum pressure ratio. Beyond the point of maximum pressure ratio, this effect is not distinguishable from the reduction of separation by the bow of the vanes. Experimental results show that in cases of high aerodynamic loading, i.e. between maximum pressure ratio and the stall limit, separation is reduced in the bowed stator vanes so that the stagnation pressure ratio and efficiency are increased by the change to bowed stators. It is shown that the reduction of separation with bowed vanes leads to a increase of static pressure rise towards lower mass flow so that the present bow bladed compressor achieves higher static pressure ratios at the stall limit.

ASJC Scopus subject areas

Cite this

Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor. / Fischer, Axel; Riess, Walter; Seume, Joerg R.
2009. 429-435 Paper presented at 2003 ASME Turbo Expo, Atlanta, GA, United States.

Research output: Contribution to conferencePaperResearchpeer review

Fischer, A, Riess, W & Seume, JR 2009, 'Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor', Paper presented at 2003 ASME Turbo Expo, Atlanta, GA, United States, 16 Jun 2003 - 19 Jun 2003 pp. 429-435. https://doi.org/10.1115/GT2003-38392
Fischer, A., Riess, W., & Seume, J. R. (2009). Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor. 429-435. Paper presented at 2003 ASME Turbo Expo, Atlanta, GA, United States. https://doi.org/10.1115/GT2003-38392
Fischer A, Riess W, Seume JR. Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor. 2009. Paper presented at 2003 ASME Turbo Expo, Atlanta, GA, United States. doi: 10.1115/GT2003-38392
Fischer, Axel ; Riess, Walter ; Seume, Joerg R. / Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor. Paper presented at 2003 ASME Turbo Expo, Atlanta, GA, United States.7 p.
Download
@conference{d3f168c80af84f06a4e8dbb6e8cf8449,
title = "Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor",
abstract = "The FVV-sponsored-Project {"}Bow Blading{"} (c.f. acknowledgments) at the Turbomachinery Laboratory of the University of Hannover addresses the effect of strongly bowed stator vanes on the flow field in an 4-stage high speed axial compressor with controlled diffusion airfoil (CDA) blading. The compressor is equipped with more strongly bowed vanes than have previously been reported in the literature. The performance map of the present compressor is being investigated experimentally and numerically. The results show that the pressure ratio and the efficiency at the design point and at the choke limit are reduced by the increase in friction losses on the surface of the bowed vanes, whose surface area is greater than that of the reference (CDA) vanes. The mass flow at the choke limit decreases for the same reason. Because of the change in the radial distribution of axial velocity, pressure rise shifts from stage 3 to stage 4 between the choke limit and maximum pressure ratio. Beyond the point of maximum pressure ratio, this effect is not distinguishable from the reduction of separation by the bow of the vanes. Experimental results show that in cases of high aerodynamic loading, i.e. between maximum pressure ratio and the stall limit, separation is reduced in the bowed stator vanes so that the stagnation pressure ratio and efficiency are increased by the change to bowed stators. It is shown that the reduction of separation with bowed vanes leads to a increase of static pressure rise towards lower mass flow so that the present bow bladed compressor achieves higher static pressure ratios at the stall limit.",
author = "Axel Fischer and Walter Riess and Seume, {Joerg R.}",
year = "2009",
doi = "10.1115/GT2003-38392",
language = "English",
pages = "429--435",
note = "2003 ASME Turbo Expo ; Conference date: 16-06-2003 Through 19-06-2003",

}

Download

TY - CONF

T1 - Performance of Strongly Bowed Stators in a 4-Stage High Speed Compressor

AU - Fischer, Axel

AU - Riess, Walter

AU - Seume, Joerg R.

PY - 2009

Y1 - 2009

N2 - The FVV-sponsored-Project "Bow Blading" (c.f. acknowledgments) at the Turbomachinery Laboratory of the University of Hannover addresses the effect of strongly bowed stator vanes on the flow field in an 4-stage high speed axial compressor with controlled diffusion airfoil (CDA) blading. The compressor is equipped with more strongly bowed vanes than have previously been reported in the literature. The performance map of the present compressor is being investigated experimentally and numerically. The results show that the pressure ratio and the efficiency at the design point and at the choke limit are reduced by the increase in friction losses on the surface of the bowed vanes, whose surface area is greater than that of the reference (CDA) vanes. The mass flow at the choke limit decreases for the same reason. Because of the change in the radial distribution of axial velocity, pressure rise shifts from stage 3 to stage 4 between the choke limit and maximum pressure ratio. Beyond the point of maximum pressure ratio, this effect is not distinguishable from the reduction of separation by the bow of the vanes. Experimental results show that in cases of high aerodynamic loading, i.e. between maximum pressure ratio and the stall limit, separation is reduced in the bowed stator vanes so that the stagnation pressure ratio and efficiency are increased by the change to bowed stators. It is shown that the reduction of separation with bowed vanes leads to a increase of static pressure rise towards lower mass flow so that the present bow bladed compressor achieves higher static pressure ratios at the stall limit.

AB - The FVV-sponsored-Project "Bow Blading" (c.f. acknowledgments) at the Turbomachinery Laboratory of the University of Hannover addresses the effect of strongly bowed stator vanes on the flow field in an 4-stage high speed axial compressor with controlled diffusion airfoil (CDA) blading. The compressor is equipped with more strongly bowed vanes than have previously been reported in the literature. The performance map of the present compressor is being investigated experimentally and numerically. The results show that the pressure ratio and the efficiency at the design point and at the choke limit are reduced by the increase in friction losses on the surface of the bowed vanes, whose surface area is greater than that of the reference (CDA) vanes. The mass flow at the choke limit decreases for the same reason. Because of the change in the radial distribution of axial velocity, pressure rise shifts from stage 3 to stage 4 between the choke limit and maximum pressure ratio. Beyond the point of maximum pressure ratio, this effect is not distinguishable from the reduction of separation by the bow of the vanes. Experimental results show that in cases of high aerodynamic loading, i.e. between maximum pressure ratio and the stall limit, separation is reduced in the bowed stator vanes so that the stagnation pressure ratio and efficiency are increased by the change to bowed stators. It is shown that the reduction of separation with bowed vanes leads to a increase of static pressure rise towards lower mass flow so that the present bow bladed compressor achieves higher static pressure ratios at the stall limit.

UR - http://www.scopus.com/inward/record.url?scp=0346334272&partnerID=8YFLogxK

U2 - 10.1115/GT2003-38392

DO - 10.1115/GT2003-38392

M3 - Paper

AN - SCOPUS:0346334272

SP - 429

EP - 435

T2 - 2003 ASME Turbo Expo

Y2 - 16 June 2003 through 19 June 2003

ER -