PARAMIS parallel robot for laparoscopic surgery

Research output: Contribution to journalArticleResearchpeer review

Authors

  • D. Pisla
  • N. Plitea
  • C. Vaida
  • Jürgen Hesselbach
  • Annika Raatz
  • L. Vlad
  • F. Graur
  • B. Gyurka
  • B. Gherman
  • M. Suciu

External Research Organisations

  • Technical University of Cluj-Napoca
  • Technische Universität Braunschweig
  • Iuliu Hatieganu University of Medicine and Pharmacy
  • S.C. IPA S.A. Cluj-Napoca Subsidiary
View graph of relations

Details

Original languageEnglish
Pages (from-to)677-683
Number of pages7
JournalChirurgia (Romania)
Volume107
Issue number5
Publication statusPublished - Dec 2010
Externally publishedYes

Abstract

The paper presents the parallel robot, which has been developed in Romania and it is used for laparoscope camera positioning. Based on its mathematical modeling, the first low-cost experimental model of the PARAMIS surgical robot has been built. The system has been built in such a way that it has the possibility to transform it in a multiarm robot controlled from the console. The control input allows the user to give commands in a large area for the positioning of the laparoscope using different interfaces: joystick, microphone, keyboard & mouse and haptic device. The first results have been obtained through the performing of an experimental laparoscopic cholecystectomy using PARAMIS surgical robot. The model which was used was a porcine liver, removed with the gall-bladder and the bile ducts. Due to its very easy use control system, surgeons have adapted rapidly to the use of PARAMIS in surgical procedures. Some of its advantages could be emphasized: precision of the movements; absence of the laparoscope operator's natural tremor, direct control over a smooth, precise, stable view of the internal surgical field for the surgeon; no fatigue; allows the use of both hands for the actual procedure; reduces eye fatigue; eliminates the need for a second surgeon to be present for the entire procedure.

Keywords

    Cholecystectomy, Control system, Interface, Parallel robot, Robotic surgery, Simulation

ASJC Scopus subject areas

Cite this

PARAMIS parallel robot for laparoscopic surgery. / Pisla, D.; Plitea, N.; Vaida, C. et al.
In: Chirurgia (Romania), Vol. 107, No. 5, 12.2010, p. 677-683.

Research output: Contribution to journalArticleResearchpeer review

Pisla, D, Plitea, N, Vaida, C, Hesselbach, J, Raatz, A, Vlad, L, Graur, F, Gyurka, B, Gherman, B & Suciu, M 2010, 'PARAMIS parallel robot for laparoscopic surgery', Chirurgia (Romania), vol. 107, no. 5, pp. 677-683.
Pisla, D., Plitea, N., Vaida, C., Hesselbach, J., Raatz, A., Vlad, L., Graur, F., Gyurka, B., Gherman, B., & Suciu, M. (2010). PARAMIS parallel robot for laparoscopic surgery. Chirurgia (Romania), 107(5), 677-683.
Pisla D, Plitea N, Vaida C, Hesselbach J, Raatz A, Vlad L et al. PARAMIS parallel robot for laparoscopic surgery. Chirurgia (Romania). 2010 Dec;107(5):677-683.
Pisla, D. ; Plitea, N. ; Vaida, C. et al. / PARAMIS parallel robot for laparoscopic surgery. In: Chirurgia (Romania). 2010 ; Vol. 107, No. 5. pp. 677-683.
Download
@article{616affce5b94419e9d44964c8a6b2ab7,
title = "PARAMIS parallel robot for laparoscopic surgery",
abstract = "The paper presents the parallel robot, which has been developed in Romania and it is used for laparoscope camera positioning. Based on its mathematical modeling, the first low-cost experimental model of the PARAMIS surgical robot has been built. The system has been built in such a way that it has the possibility to transform it in a multiarm robot controlled from the console. The control input allows the user to give commands in a large area for the positioning of the laparoscope using different interfaces: joystick, microphone, keyboard & mouse and haptic device. The first results have been obtained through the performing of an experimental laparoscopic cholecystectomy using PARAMIS surgical robot. The model which was used was a porcine liver, removed with the gall-bladder and the bile ducts. Due to its very easy use control system, surgeons have adapted rapidly to the use of PARAMIS in surgical procedures. Some of its advantages could be emphasized: precision of the movements; absence of the laparoscope operator's natural tremor, direct control over a smooth, precise, stable view of the internal surgical field for the surgeon; no fatigue; allows the use of both hands for the actual procedure; reduces eye fatigue; eliminates the need for a second surgeon to be present for the entire procedure.",
keywords = "Cholecystectomy, Control system, Interface, Parallel robot, Robotic surgery, Simulation",
author = "D. Pisla and N. Plitea and C. Vaida and J{\"u}rgen Hesselbach and Annika Raatz and L. Vlad and F. Graur and B. Gyurka and B. Gherman and M. Suciu",
year = "2010",
month = dec,
language = "English",
volume = "107",
pages = "677--683",
number = "5",

}

Download

TY - JOUR

T1 - PARAMIS parallel robot for laparoscopic surgery

AU - Pisla, D.

AU - Plitea, N.

AU - Vaida, C.

AU - Hesselbach, Jürgen

AU - Raatz, Annika

AU - Vlad, L.

AU - Graur, F.

AU - Gyurka, B.

AU - Gherman, B.

AU - Suciu, M.

PY - 2010/12

Y1 - 2010/12

N2 - The paper presents the parallel robot, which has been developed in Romania and it is used for laparoscope camera positioning. Based on its mathematical modeling, the first low-cost experimental model of the PARAMIS surgical robot has been built. The system has been built in such a way that it has the possibility to transform it in a multiarm robot controlled from the console. The control input allows the user to give commands in a large area for the positioning of the laparoscope using different interfaces: joystick, microphone, keyboard & mouse and haptic device. The first results have been obtained through the performing of an experimental laparoscopic cholecystectomy using PARAMIS surgical robot. The model which was used was a porcine liver, removed with the gall-bladder and the bile ducts. Due to its very easy use control system, surgeons have adapted rapidly to the use of PARAMIS in surgical procedures. Some of its advantages could be emphasized: precision of the movements; absence of the laparoscope operator's natural tremor, direct control over a smooth, precise, stable view of the internal surgical field for the surgeon; no fatigue; allows the use of both hands for the actual procedure; reduces eye fatigue; eliminates the need for a second surgeon to be present for the entire procedure.

AB - The paper presents the parallel robot, which has been developed in Romania and it is used for laparoscope camera positioning. Based on its mathematical modeling, the first low-cost experimental model of the PARAMIS surgical robot has been built. The system has been built in such a way that it has the possibility to transform it in a multiarm robot controlled from the console. The control input allows the user to give commands in a large area for the positioning of the laparoscope using different interfaces: joystick, microphone, keyboard & mouse and haptic device. The first results have been obtained through the performing of an experimental laparoscopic cholecystectomy using PARAMIS surgical robot. The model which was used was a porcine liver, removed with the gall-bladder and the bile ducts. Due to its very easy use control system, surgeons have adapted rapidly to the use of PARAMIS in surgical procedures. Some of its advantages could be emphasized: precision of the movements; absence of the laparoscope operator's natural tremor, direct control over a smooth, precise, stable view of the internal surgical field for the surgeon; no fatigue; allows the use of both hands for the actual procedure; reduces eye fatigue; eliminates the need for a second surgeon to be present for the entire procedure.

KW - Cholecystectomy

KW - Control system

KW - Interface

KW - Parallel robot

KW - Robotic surgery

KW - Simulation

UR - http://www.scopus.com/inward/record.url?scp=84874095518&partnerID=8YFLogxK

M3 - Article

C2 - 21141094

AN - SCOPUS:84874095518

VL - 107

SP - 677

EP - 683

JO - Chirurgia (Romania)

JF - Chirurgia (Romania)

SN - 1221-9118

IS - 5

ER -