Details
Original language | English |
---|---|
Pages (from-to) | 507-516 |
Number of pages | 10 |
Journal | Journal of Quantitative Spectroscopy and Radiative Transfer |
Volume | 29 |
Issue number | 6 |
Publication status | Published - Jun 1983 |
Abstract
Oscillator strengths of 174 Mo(I) and 58 Mo(II) lines in the range 2470-5570 Å were obtained from wall-stabilised arc and hollow cathode measurements. Sets of relative f-values were determined by a combination of hook and emission measurements requiring no assumptions concerning the plasma state. The sets have been enlarged considerably by evaluating spectra recorded with a Fourier spectrometer. The relative Mo(I) f-values were converted to an absolute scale by means of radiative lifetimes measured by P. Zimmermann and his group. The overall uncertainties are within 10-35%. Since lifetimes of Mo(II) levels are not yet available, only relative Mo(II) f-values are presented.
ASJC Scopus subject areas
- Physics and Astronomy(all)
- Radiation
- Physics and Astronomy(all)
- Atomic and Molecular Physics, and Optics
- Chemistry(all)
- Spectroscopy
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
In: Journal of Quantitative Spectroscopy and Radiative Transfer, Vol. 29, No. 6, 06.1983, p. 507-516.
Research output: Contribution to journal › Article › Research › peer review
}
TY - JOUR
T1 - Oscillator strengths of neutral and singly ionised molybdenum
AU - Schnehage, S. E.
AU - Danzmann, K.
AU - Künnemeyer, R.
AU - Kock, M.
N1 - Funding Information: Acknowledgements--This work was supported by Deutsche Forschungsgemeinschaft. We would like to thank P. Zimmermann and his group for communicating to us the Mo(l) lifetimes. We also thank E. Schulz-Gulde for a critical reading of the manuscript.
PY - 1983/6
Y1 - 1983/6
N2 - Oscillator strengths of 174 Mo(I) and 58 Mo(II) lines in the range 2470-5570 Å were obtained from wall-stabilised arc and hollow cathode measurements. Sets of relative f-values were determined by a combination of hook and emission measurements requiring no assumptions concerning the plasma state. The sets have been enlarged considerably by evaluating spectra recorded with a Fourier spectrometer. The relative Mo(I) f-values were converted to an absolute scale by means of radiative lifetimes measured by P. Zimmermann and his group. The overall uncertainties are within 10-35%. Since lifetimes of Mo(II) levels are not yet available, only relative Mo(II) f-values are presented.
AB - Oscillator strengths of 174 Mo(I) and 58 Mo(II) lines in the range 2470-5570 Å were obtained from wall-stabilised arc and hollow cathode measurements. Sets of relative f-values were determined by a combination of hook and emission measurements requiring no assumptions concerning the plasma state. The sets have been enlarged considerably by evaluating spectra recorded with a Fourier spectrometer. The relative Mo(I) f-values were converted to an absolute scale by means of radiative lifetimes measured by P. Zimmermann and his group. The overall uncertainties are within 10-35%. Since lifetimes of Mo(II) levels are not yet available, only relative Mo(II) f-values are presented.
UR - http://www.scopus.com/inward/record.url?scp=0000048772&partnerID=8YFLogxK
U2 - 10.1016/0022-4073(83)90127-9
DO - 10.1016/0022-4073(83)90127-9
M3 - Article
AN - SCOPUS:0000048772
VL - 29
SP - 507
EP - 516
JO - Journal of Quantitative Spectroscopy and Radiative Transfer
JF - Journal of Quantitative Spectroscopy and Radiative Transfer
SN - 0022-4073
IS - 6
ER -