On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide

Research output: Contribution to journalArticleResearchpeer review

Authors

Research Organisations

External Research Organisations

  • University of Stuttgart
View graph of relations

Details

Original languageEnglish
Pages (from-to)139-143
Number of pages5
JournalJournal of biotechnology
Volume46
Issue number2
Publication statusPublished - 30 Apr 1996

Abstract

Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.

Keywords

    3-Hydroxy ester, Kinetic resolution, Lipase, On-line analysis, Supercritical carbon dioxide

ASJC Scopus subject areas

Cite this

On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide. / Bornscheuer, U.; Capewell, A.; Wendel, V. et al.
In: Journal of biotechnology, Vol. 46, No. 2, 30.04.1996, p. 139-143.

Research output: Contribution to journalArticleResearchpeer review

Bornscheuer U, Capewell A, Wendel V, Scheper T. On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide. Journal of biotechnology. 1996 Apr 30;46(2):139-143. doi: 10.1016/0168-1656(95)00195-6
Bornscheuer, U. ; Capewell, A. ; Wendel, V. et al. / On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide. In: Journal of biotechnology. 1996 ; Vol. 46, No. 2. pp. 139-143.
Download
@article{411242e8428047c2a2d638181c1a9580,
title = "On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide",
abstract = "Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.",
keywords = "3-Hydroxy ester, Kinetic resolution, Lipase, On-line analysis, Supercritical carbon dioxide",
author = "U. Bornscheuer and A. Capewell and V. Wendel and T. Scheper",
year = "1996",
month = apr,
day = "30",
doi = "10.1016/0168-1656(95)00195-6",
language = "English",
volume = "46",
pages = "139--143",
journal = "Journal of biotechnology",
issn = "0168-1656",
publisher = "Elsevier",
number = "2",

}

Download

TY - JOUR

T1 - On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide

AU - Bornscheuer, U.

AU - Capewell, A.

AU - Wendel, V.

AU - Scheper, T.

PY - 1996/4/30

Y1 - 1996/4/30

N2 - Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.

AB - Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.

KW - 3-Hydroxy ester

KW - Kinetic resolution

KW - Lipase

KW - On-line analysis

KW - Supercritical carbon dioxide

UR - http://www.scopus.com/inward/record.url?scp=0030131030&partnerID=8YFLogxK

U2 - 10.1016/0168-1656(95)00195-6

DO - 10.1016/0168-1656(95)00195-6

M3 - Article

AN - SCOPUS:0030131030

VL - 46

SP - 139

EP - 143

JO - Journal of biotechnology

JF - Journal of biotechnology

SN - 0168-1656

IS - 2

ER -

By the same author(s)