Abstract

A new method to exert EML forces along the z-axis is presented, consisting in the utilization of two homogeneous sinusoidal magnetic fields of different frequencies, whose field lines in absence of a charge are horizontal and reciprocally normal. The two-frequency device comprises a magnetic core composed of a yoke and four teeth, onto which four copper tube coils are wound. In a vertical quartz tube. The two electromagnetic fields produced by the two coil pairs were computed by the calculation method. For the free surface determination, the simplified method for the two-dimensional calculation of steady free surfaces is applied. The applicability and generality of this model is tested for a large frequency range, between 50 Hz and 30 kHz, and for the different free surface profiles of various recirculated, rotational semi- or entirely-levitated flows, driven in mono- or rotational three-phase magnetic fields.

Keywords

    Drop- and leakage-free melting, Free surface simulation, Two-frequency levitation

ASJC Scopus subject areas

Cite this

New method and devices for electromagnetic drip-and leakage-free levitation melting. / Peşteanu, Ovidiu; Baake, Egbert.
In: ISIJ international, Vol. 52, No. 5, 15.05.2012, p. 937-938.

Research output: Contribution to journalArticleResearchpeer review

Peşteanu O, Baake E. New method and devices for electromagnetic drip-and leakage-free levitation melting. ISIJ international. 2012 May 15;52(5):937-938. doi: 10.2355/isijinternational.52.937
Download
@article{3487ba5dd50c40d4bfd242d55785ee92,
title = "New method and devices for electromagnetic drip-and leakage-free levitation melting",
abstract = "A new method to exert EML forces along the z-axis is presented, consisting in the utilization of two homogeneous sinusoidal magnetic fields of different frequencies, whose field lines in absence of a charge are horizontal and reciprocally normal. The two-frequency device comprises a magnetic core composed of a yoke and four teeth, onto which four copper tube coils are wound. In a vertical quartz tube. The two electromagnetic fields produced by the two coil pairs were computed by the calculation method. For the free surface determination, the simplified method for the two-dimensional calculation of steady free surfaces is applied. The applicability and generality of this model is tested for a large frequency range, between 50 Hz and 30 kHz, and for the different free surface profiles of various recirculated, rotational semi- or entirely-levitated flows, driven in mono- or rotational three-phase magnetic fields.",
keywords = "Drop- and leakage-free melting, Free surface simulation, Two-frequency levitation",
author = "Ovidiu Pe{\c s}teanu and Egbert Baake",
year = "2012",
month = may,
day = "15",
doi = "10.2355/isijinternational.52.937",
language = "English",
volume = "52",
pages = "937--938",
journal = "ISIJ international",
issn = "0915-1559",
publisher = "Iron and Steel Institute of Japan",
number = "5",

}

Download

TY - JOUR

T1 - New method and devices for electromagnetic drip-and leakage-free levitation melting

AU - Peşteanu, Ovidiu

AU - Baake, Egbert

PY - 2012/5/15

Y1 - 2012/5/15

N2 - A new method to exert EML forces along the z-axis is presented, consisting in the utilization of two homogeneous sinusoidal magnetic fields of different frequencies, whose field lines in absence of a charge are horizontal and reciprocally normal. The two-frequency device comprises a magnetic core composed of a yoke and four teeth, onto which four copper tube coils are wound. In a vertical quartz tube. The two electromagnetic fields produced by the two coil pairs were computed by the calculation method. For the free surface determination, the simplified method for the two-dimensional calculation of steady free surfaces is applied. The applicability and generality of this model is tested for a large frequency range, between 50 Hz and 30 kHz, and for the different free surface profiles of various recirculated, rotational semi- or entirely-levitated flows, driven in mono- or rotational three-phase magnetic fields.

AB - A new method to exert EML forces along the z-axis is presented, consisting in the utilization of two homogeneous sinusoidal magnetic fields of different frequencies, whose field lines in absence of a charge are horizontal and reciprocally normal. The two-frequency device comprises a magnetic core composed of a yoke and four teeth, onto which four copper tube coils are wound. In a vertical quartz tube. The two electromagnetic fields produced by the two coil pairs were computed by the calculation method. For the free surface determination, the simplified method for the two-dimensional calculation of steady free surfaces is applied. The applicability and generality of this model is tested for a large frequency range, between 50 Hz and 30 kHz, and for the different free surface profiles of various recirculated, rotational semi- or entirely-levitated flows, driven in mono- or rotational three-phase magnetic fields.

KW - Drop- and leakage-free melting

KW - Free surface simulation

KW - Two-frequency levitation

UR - http://www.scopus.com/inward/record.url?scp=84863102992&partnerID=8YFLogxK

U2 - 10.2355/isijinternational.52.937

DO - 10.2355/isijinternational.52.937

M3 - Article

AN - SCOPUS:84863102992

VL - 52

SP - 937

EP - 938

JO - ISIJ international

JF - ISIJ international

SN - 0915-1559

IS - 5

ER -