Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Dierk Fricke
  • Alexander Becker
  • Lennart Jütte
  • Michael Bode
  • Dominik de Cassan
  • Merve Wollweber
  • Birgit Glasmacher
  • Bernhard Roth

External Research Organisations

  • Technische Universität Braunschweig
  • Laser Zentrum Hannover e.V. (LZH)
View graph of relations

Details

Original languageEnglish
Article number2062
JournalPolymers
Volume11
Issue number12
Early online date11 Dec 2019
Publication statusPublished - Dec 2019

Abstract

Electrospun fiber scaffolds are gaining in importance in the area of tissue engineering. They can be used, for example, to fabricate graded implants to mimic the tendon bone junction. For the grading of the tensile strength of the fiber scaffolds, the orientation of the fibers plays a major role. This is currently measured by hand in scanning electron microscope (SEM) images. In this work, a correlation between polarimetric information generated by measuring the Mueller matrix (MM) and the orientation of the fibers of electrospun fiber scaffolds is reported. For this, the MM of fiber scaffolds, which were manufactured with different production parameters, was measured and analyzed. These data were correlated with fiber orientation and mechanical properties, which were evaluated in an established manner. We found that by measurement of the MM the production parameters as well as the relative orientation of the fibers in space can be determined. Thus, the MM measurement is suitable as an alternative tool for non-contact, non-destructive determination of the production parameters and, thus, the degree of alignment of electrospun fiber scaffolds.

Keywords

    Electrospinning, Fiber alignment, Mueller matrix, Polycaprolactone, Tissue engineering

ASJC Scopus subject areas

Cite this

Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering. / Fricke, Dierk; Becker, Alexander; Jütte, Lennart et al.
In: Polymers, Vol. 11, No. 12, 2062, 12.2019.

Research output: Contribution to journalArticleResearchpeer review

Fricke, D, Becker, A, Jütte, L, Bode, M, de Cassan, D, Wollweber, M, Glasmacher, B & Roth, B 2019, 'Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering', Polymers, vol. 11, no. 12, 2062. https://doi.org/10.3390/polym11122062, https://doi.org/10.15488/10768
Fricke, D., Becker, A., Jütte, L., Bode, M., de Cassan, D., Wollweber, M., Glasmacher, B., & Roth, B. (2019). Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering. Polymers, 11(12), Article 2062. https://doi.org/10.3390/polym11122062, https://doi.org/10.15488/10768
Fricke D, Becker A, Jütte L, Bode M, de Cassan D, Wollweber M et al. Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering. Polymers. 2019 Dec;11(12):2062. Epub 2019 Dec 11. doi: 10.3390/polym11122062, 10.15488/10768
Fricke, Dierk ; Becker, Alexander ; Jütte, Lennart et al. / Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering. In: Polymers. 2019 ; Vol. 11, No. 12.
Download
@article{dbad745da84148d2b6b82817199d5e8f,
title = "Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering",
abstract = "Electrospun fiber scaffolds are gaining in importance in the area of tissue engineering. They can be used, for example, to fabricate graded implants to mimic the tendon bone junction. For the grading of the tensile strength of the fiber scaffolds, the orientation of the fibers plays a major role. This is currently measured by hand in scanning electron microscope (SEM) images. In this work, a correlation between polarimetric information generated by measuring the Mueller matrix (MM) and the orientation of the fibers of electrospun fiber scaffolds is reported. For this, the MM of fiber scaffolds, which were manufactured with different production parameters, was measured and analyzed. These data were correlated with fiber orientation and mechanical properties, which were evaluated in an established manner. We found that by measurement of the MM the production parameters as well as the relative orientation of the fibers in space can be determined. Thus, the MM measurement is suitable as an alternative tool for non-contact, non-destructive determination of the production parameters and, thus, the degree of alignment of electrospun fiber scaffolds.",
keywords = "Electrospinning, Fiber alignment, Mueller matrix, Polycaprolactone, Tissue engineering",
author = "Dierk Fricke and Alexander Becker and Lennart J{\"u}tte and Michael Bode and {de Cassan}, Dominik and Merve Wollweber and Birgit Glasmacher and Bernhard Roth",
note = "Funding information: This project is funded by the Lower Saxony Ministry for Culture and Science (MWK) through the program Tailored Light and the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany{\textquoteright}s Excellence Strategy within the Cluster of Excellence PhoenixD (EXC 2122, Project ID 390833453). The research project is also supported by the DFG in the framework of the Research Unit 2180. “Graded Implants for Tendon-Bone Junctions”.",
year = "2019",
month = dec,
doi = "10.3390/polym11122062",
language = "English",
volume = "11",
journal = "Polymers",
issn = "2073-4360",
publisher = "MDPI AG",
number = "12",

}

Download

TY - JOUR

T1 - Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering

AU - Fricke, Dierk

AU - Becker, Alexander

AU - Jütte, Lennart

AU - Bode, Michael

AU - de Cassan, Dominik

AU - Wollweber, Merve

AU - Glasmacher, Birgit

AU - Roth, Bernhard

N1 - Funding information: This project is funded by the Lower Saxony Ministry for Culture and Science (MWK) through the program Tailored Light and the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany’s Excellence Strategy within the Cluster of Excellence PhoenixD (EXC 2122, Project ID 390833453). The research project is also supported by the DFG in the framework of the Research Unit 2180. “Graded Implants for Tendon-Bone Junctions”.

PY - 2019/12

Y1 - 2019/12

N2 - Electrospun fiber scaffolds are gaining in importance in the area of tissue engineering. They can be used, for example, to fabricate graded implants to mimic the tendon bone junction. For the grading of the tensile strength of the fiber scaffolds, the orientation of the fibers plays a major role. This is currently measured by hand in scanning electron microscope (SEM) images. In this work, a correlation between polarimetric information generated by measuring the Mueller matrix (MM) and the orientation of the fibers of electrospun fiber scaffolds is reported. For this, the MM of fiber scaffolds, which were manufactured with different production parameters, was measured and analyzed. These data were correlated with fiber orientation and mechanical properties, which were evaluated in an established manner. We found that by measurement of the MM the production parameters as well as the relative orientation of the fibers in space can be determined. Thus, the MM measurement is suitable as an alternative tool for non-contact, non-destructive determination of the production parameters and, thus, the degree of alignment of electrospun fiber scaffolds.

AB - Electrospun fiber scaffolds are gaining in importance in the area of tissue engineering. They can be used, for example, to fabricate graded implants to mimic the tendon bone junction. For the grading of the tensile strength of the fiber scaffolds, the orientation of the fibers plays a major role. This is currently measured by hand in scanning electron microscope (SEM) images. In this work, a correlation between polarimetric information generated by measuring the Mueller matrix (MM) and the orientation of the fibers of electrospun fiber scaffolds is reported. For this, the MM of fiber scaffolds, which were manufactured with different production parameters, was measured and analyzed. These data were correlated with fiber orientation and mechanical properties, which were evaluated in an established manner. We found that by measurement of the MM the production parameters as well as the relative orientation of the fibers in space can be determined. Thus, the MM measurement is suitable as an alternative tool for non-contact, non-destructive determination of the production parameters and, thus, the degree of alignment of electrospun fiber scaffolds.

KW - Electrospinning

KW - Fiber alignment

KW - Mueller matrix

KW - Polycaprolactone

KW - Tissue engineering

UR - http://www.scopus.com/inward/record.url?scp=85079091710&partnerID=8YFLogxK

U2 - 10.3390/polym11122062

DO - 10.3390/polym11122062

M3 - Article

AN - SCOPUS:85079091710

VL - 11

JO - Polymers

JF - Polymers

SN - 2073-4360

IS - 12

M1 - 2062

ER -