Model-based feedback control of an ultrasonic transducer for ultrasonic assisted turning using a novel digital controller

Research output: Contribution to journalConference articleResearchpeer review

Authors

  • Igor Ille
  • Jens Twiefel
View graph of relations

Details

Original languageEnglish
Pages (from-to)63-67
Number of pages5
JournalPhysics Procedia
Volume70
Publication statusPublished - 2015
EventICU International Congress on Ultrasonics, ICU 2015 - Metz, France
Duration: 11 May 201514 May 2015

Abstract

Ultrasonic turning has time variant parameters due to temperature effects and changing load conditions during the process. This results in a change of the resonance frequency and vibration amplitude. To realize constant vibration amplitudes it is necessary to control the ultrasonic transducer by a suitable feedback controller. One approach to drive such a system is to use the resonance frequency as operating point in connection with an amplitude feedback controller. The advantages of resonant driven low damped systems are low voltages and high values of effective power. This paper presents a digital system used for parameter identification and model-based feedback control of the ultrasonic turning tool. During the turning process the system load depends on several factors like chip formation, material inhomogeneity, warming and tool wear. To achieve a stable process and a uniform surface of the work piece the feedback controller has to guarantee constant vibration amplitudes of the ultrasonic tool. The controller used in this paper consists of a digital resonance controller and a current amplitude controller with a frequency of 500 Hz. The current amplitude and phase between the excitation voltage and current are determined by phase sensitive demodulation (PSD). To determine the feedback parameters a model-based approach is used.

Keywords

    Averaging Model, Feedback Control, Model-based, Resonating Systems

ASJC Scopus subject areas

Cite this

Model-based feedback control of an ultrasonic transducer for ultrasonic assisted turning using a novel digital controller. / Ille, Igor; Twiefel, Jens.
In: Physics Procedia, Vol. 70, 2015, p. 63-67.

Research output: Contribution to journalConference articleResearchpeer review

Ille I, Twiefel J. Model-based feedback control of an ultrasonic transducer for ultrasonic assisted turning using a novel digital controller. Physics Procedia. 2015;70:63-67. doi: 10.1016/j.phpro.2015.08.043
Download
@article{5cbe4eaa45e64e6cb89eb77ca03dc3e9,
title = "Model-based feedback control of an ultrasonic transducer for ultrasonic assisted turning using a novel digital controller",
abstract = "Ultrasonic turning has time variant parameters due to temperature effects and changing load conditions during the process. This results in a change of the resonance frequency and vibration amplitude. To realize constant vibration amplitudes it is necessary to control the ultrasonic transducer by a suitable feedback controller. One approach to drive such a system is to use the resonance frequency as operating point in connection with an amplitude feedback controller. The advantages of resonant driven low damped systems are low voltages and high values of effective power. This paper presents a digital system used for parameter identification and model-based feedback control of the ultrasonic turning tool. During the turning process the system load depends on several factors like chip formation, material inhomogeneity, warming and tool wear. To achieve a stable process and a uniform surface of the work piece the feedback controller has to guarantee constant vibration amplitudes of the ultrasonic tool. The controller used in this paper consists of a digital resonance controller and a current amplitude controller with a frequency of 500 Hz. The current amplitude and phase between the excitation voltage and current are determined by phase sensitive demodulation (PSD). To determine the feedback parameters a model-based approach is used.",
keywords = "Averaging Model, Feedback Control, Model-based, Resonating Systems",
author = "Igor Ille and Jens Twiefel",
year = "2015",
doi = "10.1016/j.phpro.2015.08.043",
language = "English",
volume = "70",
pages = "63--67",
note = "ICU International Congress on Ultrasonics, ICU 2015 ; Conference date: 11-05-2015 Through 14-05-2015",

}

Download

TY - JOUR

T1 - Model-based feedback control of an ultrasonic transducer for ultrasonic assisted turning using a novel digital controller

AU - Ille, Igor

AU - Twiefel, Jens

PY - 2015

Y1 - 2015

N2 - Ultrasonic turning has time variant parameters due to temperature effects and changing load conditions during the process. This results in a change of the resonance frequency and vibration amplitude. To realize constant vibration amplitudes it is necessary to control the ultrasonic transducer by a suitable feedback controller. One approach to drive such a system is to use the resonance frequency as operating point in connection with an amplitude feedback controller. The advantages of resonant driven low damped systems are low voltages and high values of effective power. This paper presents a digital system used for parameter identification and model-based feedback control of the ultrasonic turning tool. During the turning process the system load depends on several factors like chip formation, material inhomogeneity, warming and tool wear. To achieve a stable process and a uniform surface of the work piece the feedback controller has to guarantee constant vibration amplitudes of the ultrasonic tool. The controller used in this paper consists of a digital resonance controller and a current amplitude controller with a frequency of 500 Hz. The current amplitude and phase between the excitation voltage and current are determined by phase sensitive demodulation (PSD). To determine the feedback parameters a model-based approach is used.

AB - Ultrasonic turning has time variant parameters due to temperature effects and changing load conditions during the process. This results in a change of the resonance frequency and vibration amplitude. To realize constant vibration amplitudes it is necessary to control the ultrasonic transducer by a suitable feedback controller. One approach to drive such a system is to use the resonance frequency as operating point in connection with an amplitude feedback controller. The advantages of resonant driven low damped systems are low voltages and high values of effective power. This paper presents a digital system used for parameter identification and model-based feedback control of the ultrasonic turning tool. During the turning process the system load depends on several factors like chip formation, material inhomogeneity, warming and tool wear. To achieve a stable process and a uniform surface of the work piece the feedback controller has to guarantee constant vibration amplitudes of the ultrasonic tool. The controller used in this paper consists of a digital resonance controller and a current amplitude controller with a frequency of 500 Hz. The current amplitude and phase between the excitation voltage and current are determined by phase sensitive demodulation (PSD). To determine the feedback parameters a model-based approach is used.

KW - Averaging Model

KW - Feedback Control

KW - Model-based

KW - Resonating Systems

UR - http://www.scopus.com/inward/record.url?scp=84948674596&partnerID=8YFLogxK

U2 - 10.1016/j.phpro.2015.08.043

DO - 10.1016/j.phpro.2015.08.043

M3 - Conference article

AN - SCOPUS:84948674596

VL - 70

SP - 63

EP - 67

JO - Physics Procedia

JF - Physics Procedia

SN - 1875-3884

T2 - ICU International Congress on Ultrasonics, ICU 2015

Y2 - 11 May 2015 through 14 May 2015

ER -