MgNd2 alloy in contact with nasal mucosa: an in vivo and in vitro approach

Research output: Contribution to journalArticleResearchpeer review

Authors

  • R. Eifler
  • J. M. Seitz
  • C. M. Weber
  • S. Grundke
  • J. Reifenrath
  • M. Kietzmann
  • T. H. Lenarz
  • H. J. Maier
  • C. Klose
  • M. Durisin

Research Organisations

External Research Organisations

  • Michigan Technological University
  • Hannover Medical School (MHH)
  • University of Veterinary Medicine of Hannover, Foundation
View graph of relations

Details

Original languageEnglish
Article number25
Pages (from-to)1-18
Number of pages18
JournalJournal of Materials Science: Materials in Medicine
Volume27
Issue number2
Publication statusPublished - 24 Dec 2015

Abstract

Biodegradable and biocompatible magnesium alloys appear to be very promising not only for temporary clinical application but also for developing deformable and degradable medical implants. This study analyzes the in vivo degradation behavior and the impact on the paranasal sinuses of the highly ductile Mg-2 wt%Nd alloy (MgNd2) in order to provide a basis for a satisfying stent system for the therapy of a chronic sinusitis. Moreover, in vitro tests were carried out on primary porcine nasal epithelial cells (PNEC). For the in vivo tests, cylindrical MgNd2 specimens were implanted into the sinus’ mucosa of minipigs. During and after a total period of 180 days the long-term biodegradation and biocompatibility properties after direct contact with the physiological tissue were analyzed. Biodegradation was investigated by measuring the mass and volume losses of the MgNd2 specimens as well as by performing element analyses to obtain information about the degradation layer. The influence on the surrounding tissue of paranasal sinuses was evaluated by endoscopic and histopathological examinations of the mucosa. Here, only a locally unspecific chronic infection was found. The degradation rate showed a maximum after 45 days postsurgery and was determined to decrease subsequently. In vitro experiments using PNEC showed adequate biocompatibility of MgNd2. This study demonstrates a good in vivo biocompatibility for MgNd2 in the system of paranasal sinuses and underlines the promising properties of alloy MgNd2 for biodegradable nasal stent applications.

ASJC Scopus subject areas

Cite this

MgNd2 alloy in contact with nasal mucosa: an in vivo and in vitro approach. / Eifler, R.; Seitz, J. M.; Weber, C. M. et al.
In: Journal of Materials Science: Materials in Medicine, Vol. 27, No. 2, 25, 24.12.2015, p. 1-18.

Research output: Contribution to journalArticleResearchpeer review

Eifler, R, Seitz, JM, Weber, CM, Grundke, S, Reifenrath, J, Kietzmann, M, Lenarz, TH, Maier, HJ, Klose, C & Durisin, M 2015, 'MgNd2 alloy in contact with nasal mucosa: an in vivo and in vitro approach', Journal of Materials Science: Materials in Medicine, vol. 27, no. 2, 25, pp. 1-18. https://doi.org/10.1007/s10856-015-5636-7
Eifler, R., Seitz, J. M., Weber, C. M., Grundke, S., Reifenrath, J., Kietzmann, M., Lenarz, T. H., Maier, H. J., Klose, C., & Durisin, M. (2015). MgNd2 alloy in contact with nasal mucosa: an in vivo and in vitro approach. Journal of Materials Science: Materials in Medicine, 27(2), 1-18. Article 25. https://doi.org/10.1007/s10856-015-5636-7
Eifler R, Seitz JM, Weber CM, Grundke S, Reifenrath J, Kietzmann M et al. MgNd2 alloy in contact with nasal mucosa: an in vivo and in vitro approach. Journal of Materials Science: Materials in Medicine. 2015 Dec 24;27(2):1-18. 25. doi: 10.1007/s10856-015-5636-7
Eifler, R. ; Seitz, J. M. ; Weber, C. M. et al. / MgNd2 alloy in contact with nasal mucosa : an in vivo and in vitro approach. In: Journal of Materials Science: Materials in Medicine. 2015 ; Vol. 27, No. 2. pp. 1-18.
Download
@article{dc36db0d43634d63b47e50ef1074f8ad,
title = "MgNd2 alloy in contact with nasal mucosa: an in vivo and in vitro approach",
abstract = "Biodegradable and biocompatible magnesium alloys appear to be very promising not only for temporary clinical application but also for developing deformable and degradable medical implants. This study analyzes the in vivo degradation behavior and the impact on the paranasal sinuses of the highly ductile Mg-2 wt%Nd alloy (MgNd2) in order to provide a basis for a satisfying stent system for the therapy of a chronic sinusitis. Moreover, in vitro tests were carried out on primary porcine nasal epithelial cells (PNEC). For the in vivo tests, cylindrical MgNd2 specimens were implanted into the sinus{\textquoteright} mucosa of minipigs. During and after a total period of 180 days the long-term biodegradation and biocompatibility properties after direct contact with the physiological tissue were analyzed. Biodegradation was investigated by measuring the mass and volume losses of the MgNd2 specimens as well as by performing element analyses to obtain information about the degradation layer. The influence on the surrounding tissue of paranasal sinuses was evaluated by endoscopic and histopathological examinations of the mucosa. Here, only a locally unspecific chronic infection was found. The degradation rate showed a maximum after 45 days postsurgery and was determined to decrease subsequently. In vitro experiments using PNEC showed adequate biocompatibility of MgNd2. This study demonstrates a good in vivo biocompatibility for MgNd2 in the system of paranasal sinuses and underlines the promising properties of alloy MgNd2 for biodegradable nasal stent applications.",
author = "R. Eifler and Seitz, {J. M.} and Weber, {C. M.} and S. Grundke and J. Reifenrath and M. Kietzmann and Lenarz, {T. H.} and Maier, {H. J.} and C. Klose and M. Durisin",
year = "2015",
month = dec,
day = "24",
doi = "10.1007/s10856-015-5636-7",
language = "English",
volume = "27",
pages = "1--18",
journal = "Journal of Materials Science: Materials in Medicine",
issn = "0957-4530",
publisher = "Springer Netherlands",
number = "2",

}

Download

TY - JOUR

T1 - MgNd2 alloy in contact with nasal mucosa

T2 - an in vivo and in vitro approach

AU - Eifler, R.

AU - Seitz, J. M.

AU - Weber, C. M.

AU - Grundke, S.

AU - Reifenrath, J.

AU - Kietzmann, M.

AU - Lenarz, T. H.

AU - Maier, H. J.

AU - Klose, C.

AU - Durisin, M.

PY - 2015/12/24

Y1 - 2015/12/24

N2 - Biodegradable and biocompatible magnesium alloys appear to be very promising not only for temporary clinical application but also for developing deformable and degradable medical implants. This study analyzes the in vivo degradation behavior and the impact on the paranasal sinuses of the highly ductile Mg-2 wt%Nd alloy (MgNd2) in order to provide a basis for a satisfying stent system for the therapy of a chronic sinusitis. Moreover, in vitro tests were carried out on primary porcine nasal epithelial cells (PNEC). For the in vivo tests, cylindrical MgNd2 specimens were implanted into the sinus’ mucosa of minipigs. During and after a total period of 180 days the long-term biodegradation and biocompatibility properties after direct contact with the physiological tissue were analyzed. Biodegradation was investigated by measuring the mass and volume losses of the MgNd2 specimens as well as by performing element analyses to obtain information about the degradation layer. The influence on the surrounding tissue of paranasal sinuses was evaluated by endoscopic and histopathological examinations of the mucosa. Here, only a locally unspecific chronic infection was found. The degradation rate showed a maximum after 45 days postsurgery and was determined to decrease subsequently. In vitro experiments using PNEC showed adequate biocompatibility of MgNd2. This study demonstrates a good in vivo biocompatibility for MgNd2 in the system of paranasal sinuses and underlines the promising properties of alloy MgNd2 for biodegradable nasal stent applications.

AB - Biodegradable and biocompatible magnesium alloys appear to be very promising not only for temporary clinical application but also for developing deformable and degradable medical implants. This study analyzes the in vivo degradation behavior and the impact on the paranasal sinuses of the highly ductile Mg-2 wt%Nd alloy (MgNd2) in order to provide a basis for a satisfying stent system for the therapy of a chronic sinusitis. Moreover, in vitro tests were carried out on primary porcine nasal epithelial cells (PNEC). For the in vivo tests, cylindrical MgNd2 specimens were implanted into the sinus’ mucosa of minipigs. During and after a total period of 180 days the long-term biodegradation and biocompatibility properties after direct contact with the physiological tissue were analyzed. Biodegradation was investigated by measuring the mass and volume losses of the MgNd2 specimens as well as by performing element analyses to obtain information about the degradation layer. The influence on the surrounding tissue of paranasal sinuses was evaluated by endoscopic and histopathological examinations of the mucosa. Here, only a locally unspecific chronic infection was found. The degradation rate showed a maximum after 45 days postsurgery and was determined to decrease subsequently. In vitro experiments using PNEC showed adequate biocompatibility of MgNd2. This study demonstrates a good in vivo biocompatibility for MgNd2 in the system of paranasal sinuses and underlines the promising properties of alloy MgNd2 for biodegradable nasal stent applications.

UR - http://www.scopus.com/inward/record.url?scp=84951292963&partnerID=8YFLogxK

U2 - 10.1007/s10856-015-5636-7

DO - 10.1007/s10856-015-5636-7

M3 - Article

C2 - 26704542

AN - SCOPUS:84951292963

VL - 27

SP - 1

EP - 18

JO - Journal of Materials Science: Materials in Medicine

JF - Journal of Materials Science: Materials in Medicine

SN - 0957-4530

IS - 2

M1 - 25

ER -

By the same author(s)