Standard oil tests und dissolved gas analyses (DGA) are elementary methods of the condition assessment of power transformers. Especially the DGA is based in the first step on the evaluation if the considered oil sample shows typical gas concentrations or not. In this contribution, it was investigated if relationships between the results of standard oil tests and typical DGA results or typically increased gases can be found. For this investigation a huge basis of results of oil tests from different transformers were involved.
ASJC Scopus subject areas
- Energy(all)
- Energy Engineering and Power Technology
- Engineering(all)
- Electrical and Electronic Engineering
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
VDE-Fachtagung Hochspannungstechnik 2018. VDE Verlag GmbH, 2018. p. 226-230 (VDE-Fachtagung Hochspannungstechnik 2018).
Research output: Chapter in book/report/conference proceeding › Conference contribution › Research › peer review
}
TY - GEN
T1 - Mehrdimensionale Betrachtung ölanalytischer Ergebnisse am Beispiel einer großen, realen Transformatorenflotte
AU - Schreiter, Sebastian
AU - Lohmeyer, Holger
AU - Werle, Peter
N1 - Publisher Copyright: © VDE VERLAG GMBH · Berlin · Offenbach Copyright: Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2018
Y1 - 2018
N2 - Standard oil tests und dissolved gas analyses (DGA) are elementary methods of the condition assessment of power transformers. Especially the DGA is based in the first step on the evaluation if the considered oil sample shows typical gas concentrations or not. In this contribution, it was investigated if relationships between the results of standard oil tests and typical DGA results or typically increased gases can be found. For this investigation a huge basis of results of oil tests from different transformers were involved.
AB - Standard oil tests und dissolved gas analyses (DGA) are elementary methods of the condition assessment of power transformers. Especially the DGA is based in the first step on the evaluation if the considered oil sample shows typical gas concentrations or not. In this contribution, it was investigated if relationships between the results of standard oil tests and typical DGA results or typically increased gases can be found. For this investigation a huge basis of results of oil tests from different transformers were involved.
UR - http://www.scopus.com/inward/record.url?scp=85076847765&partnerID=8YFLogxK
M3 - Aufsatz in Konferenzband
AN - SCOPUS:85076847765
T3 - VDE-Fachtagung Hochspannungstechnik 2018
SP - 226
EP - 230
BT - VDE-Fachtagung Hochspannungstechnik 2018
PB - VDE Verlag GmbH
T2 - VDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018
Y2 - 12 November 2018 through 14 November 2018
ER -