Abstract

The main goal of this research was to determine the influence of temperature and pressure on the development of partial discharges (PD) in sealed power transformers. A test vessel was developed to reproduce the conditions in a compact power transformer, which is commonly used in wind turbines. The electrode assembly resembles the structure of the high voltage winding in such a transformer. As insulation liquids a synthetic ester and a silicone fluid are investigated together with an aramid paper. This combination is typically used and allows high operating temperatures, but many of these transformers failed in the field. Therefore it was investigated how the PD inception and extinction voltage change over the temperature in an open system and how they are influenced by a change of the pressure of the gas cushion at different temperatures in a closed system. Furthermore dissolved and undissolved gases were evaluated after a stress with partial discharges over 72 hours. The obtained results show that the PD inception and extinction voltages are strongly influenced by temperature, pressure and type of gas used for the gas cushion.

Keywords

    Compact power transformer, Gas cushion, Hermetic transformer, Partial discharge

ASJC Scopus subject areas

Cite this

Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines. / Kuhnke, M.; Münster, T.; Werle, P.
2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017. Institute of Electrical and Electronics Engineers Inc., 2017. p. 1-4.

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Kuhnke, M, Münster, T & Werle, P 2017, Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines. in 2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017. Institute of Electrical and Electronics Engineers Inc., pp. 1-4, 19th IEEE International Conference on Dielectric Liquids, ICDL 2017, Manchester, United Kingdom (UK), 25 Jun 2017. https://doi.org/10.1109/icdl.2017.8124625
Kuhnke, M., Münster, T., & Werle, P. (2017). Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines. In 2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017 (pp. 1-4). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/icdl.2017.8124625
Kuhnke M, Münster T, Werle P. Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines. In 2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017. Institute of Electrical and Electronics Engineers Inc. 2017. p. 1-4 doi: 10.1109/icdl.2017.8124625
Kuhnke, M. ; Münster, T. ; Werle, P. / Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines. 2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017. Institute of Electrical and Electronics Engineers Inc., 2017. pp. 1-4
Download
@inproceedings{fd5186dc02c942deaf8aea284324c0e2,
title = "Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines",
abstract = "The main goal of this research was to determine the influence of temperature and pressure on the development of partial discharges (PD) in sealed power transformers. A test vessel was developed to reproduce the conditions in a compact power transformer, which is commonly used in wind turbines. The electrode assembly resembles the structure of the high voltage winding in such a transformer. As insulation liquids a synthetic ester and a silicone fluid are investigated together with an aramid paper. This combination is typically used and allows high operating temperatures, but many of these transformers failed in the field. Therefore it was investigated how the PD inception and extinction voltage change over the temperature in an open system and how they are influenced by a change of the pressure of the gas cushion at different temperatures in a closed system. Furthermore dissolved and undissolved gases were evaluated after a stress with partial discharges over 72 hours. The obtained results show that the PD inception and extinction voltages are strongly influenced by temperature, pressure and type of gas used for the gas cushion.",
keywords = "Compact power transformer, Gas cushion, Hermetic transformer, Partial discharge",
author = "M. Kuhnke and T. M{\"u}nster and P. Werle",
note = "Publisher Copyright: {\textcopyright} 2017 IEEE. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.; 19th IEEE International Conference on Dielectric Liquids, ICDL 2017 ; Conference date: 25-06-2017 Through 29-06-2017",
year = "2017",
month = nov,
day = "29",
doi = "10.1109/icdl.2017.8124625",
language = "English",
pages = "1--4",
booktitle = "2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
address = "United States",

}

Download

TY - GEN

T1 - Investigation on the development of load dependent partial discharges in compact power transformers of wind turbines

AU - Kuhnke, M.

AU - Münster, T.

AU - Werle, P.

N1 - Publisher Copyright: © 2017 IEEE. Copyright: Copyright 2018 Elsevier B.V., All rights reserved.

PY - 2017/11/29

Y1 - 2017/11/29

N2 - The main goal of this research was to determine the influence of temperature and pressure on the development of partial discharges (PD) in sealed power transformers. A test vessel was developed to reproduce the conditions in a compact power transformer, which is commonly used in wind turbines. The electrode assembly resembles the structure of the high voltage winding in such a transformer. As insulation liquids a synthetic ester and a silicone fluid are investigated together with an aramid paper. This combination is typically used and allows high operating temperatures, but many of these transformers failed in the field. Therefore it was investigated how the PD inception and extinction voltage change over the temperature in an open system and how they are influenced by a change of the pressure of the gas cushion at different temperatures in a closed system. Furthermore dissolved and undissolved gases were evaluated after a stress with partial discharges over 72 hours. The obtained results show that the PD inception and extinction voltages are strongly influenced by temperature, pressure and type of gas used for the gas cushion.

AB - The main goal of this research was to determine the influence of temperature and pressure on the development of partial discharges (PD) in sealed power transformers. A test vessel was developed to reproduce the conditions in a compact power transformer, which is commonly used in wind turbines. The electrode assembly resembles the structure of the high voltage winding in such a transformer. As insulation liquids a synthetic ester and a silicone fluid are investigated together with an aramid paper. This combination is typically used and allows high operating temperatures, but many of these transformers failed in the field. Therefore it was investigated how the PD inception and extinction voltage change over the temperature in an open system and how they are influenced by a change of the pressure of the gas cushion at different temperatures in a closed system. Furthermore dissolved and undissolved gases were evaluated after a stress with partial discharges over 72 hours. The obtained results show that the PD inception and extinction voltages are strongly influenced by temperature, pressure and type of gas used for the gas cushion.

KW - Compact power transformer

KW - Gas cushion

KW - Hermetic transformer

KW - Partial discharge

UR - http://www.scopus.com/inward/record.url?scp=85043518252&partnerID=8YFLogxK

U2 - 10.1109/icdl.2017.8124625

DO - 10.1109/icdl.2017.8124625

M3 - Conference contribution

AN - SCOPUS:85043518252

SP - 1

EP - 4

BT - 2017 IEEE 19th International Conference on Dielectric Liquids, ICDL 2017

PB - Institute of Electrical and Electronics Engineers Inc.

T2 - 19th IEEE International Conference on Dielectric Liquids, ICDL 2017

Y2 - 25 June 2017 through 29 June 2017

ER -

By the same author(s)