Loading [MathJax]/extensions/tex2jax.js

Influence of the hyperfine structure on plutonium in resonant laser-SNMS

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Hauke Bosco
  • Martin Weiss
  • Manuel Raiwa
  • Clemens Walther
  • Nina Kneip

External Research Organisations

  • Johannes Gutenberg University Mainz
Plum Print visual indicator of research metrics
  • Citations
    • Citation Indexes: 5
  • Captures
    • Readers: 6
see details

Details

Original languageEnglish
Article number34
JournalHyperfine Interactions
Volume241
Publication statusPublished - 3 Mar 2020

Abstract

Resonance ionization mass spectrometry is an ultra-sensitive and highly element selective tool for spectroscopy, ionization and detection of atoms and thus enables rare isotope determination. In combination with spatially resolved sputtering of neutrals by an initial ion beam, e.g. within a commercial secondary ion mass spectrometer, an isotope and isobar selective analysis technique with resolution on the micrometer scale for particles and surfaces is realized. Detection of minuscule amounts of specific actinides, e.g. of plutonium, in environmental and technical samples by this ultra-trace analysis technique requires detailed knowledge about the atomic physics of the element. Identification and characterization of the specific resonance ionization scheme applied within the particular geometry of the apparatus in use is needed. An analysis of the dependence of the specifications, specifically regarding the influence of the relative laser beam polarizations is presented here as an aspect, that could have a severe impact on isotope ratio precision and overall efficiency in the resulting ion signal.

Keywords

    Isotope ratio, Laser beam polarization, Plutonium, Resonance ionization, SNMS, Trace analysis

ASJC Scopus subject areas

Cite this

Influence of the hyperfine structure on plutonium in resonant laser-SNMS. / Bosco, Hauke; Weiss, Martin; Raiwa, Manuel et al.
In: Hyperfine Interactions, Vol. 241, 34, 03.03.2020.

Research output: Contribution to journalArticleResearchpeer review

Bosco, H, Weiss, M, Raiwa, M, Walther, C, Kneip, N & Wendt, K 2020, 'Influence of the hyperfine structure on plutonium in resonant laser-SNMS', Hyperfine Interactions, vol. 241, 34. https://doi.org/10.1007/s10751-020-1696-2
Bosco, H., Weiss, M., Raiwa, M., Walther, C., Kneip, N., & Wendt, K. (2020). Influence of the hyperfine structure on plutonium in resonant laser-SNMS. Hyperfine Interactions, 241, Article 34. https://doi.org/10.1007/s10751-020-1696-2
Bosco H, Weiss M, Raiwa M, Walther C, Kneip N, Wendt K. Influence of the hyperfine structure on plutonium in resonant laser-SNMS. Hyperfine Interactions. 2020 Mar 3;241:34. doi: 10.1007/s10751-020-1696-2
Bosco, Hauke ; Weiss, Martin ; Raiwa, Manuel et al. / Influence of the hyperfine structure on plutonium in resonant laser-SNMS. In: Hyperfine Interactions. 2020 ; Vol. 241.
Download
@article{713ab5ed304145a28f1acd17a6529da2,
title = "Influence of the hyperfine structure on plutonium in resonant laser-SNMS",
abstract = "Resonance ionization mass spectrometry is an ultra-sensitive and highly element selective tool for spectroscopy, ionization and detection of atoms and thus enables rare isotope determination. In combination with spatially resolved sputtering of neutrals by an initial ion beam, e.g. within a commercial secondary ion mass spectrometer, an isotope and isobar selective analysis technique with resolution on the micrometer scale for particles and surfaces is realized. Detection of minuscule amounts of specific actinides, e.g. of plutonium, in environmental and technical samples by this ultra-trace analysis technique requires detailed knowledge about the atomic physics of the element. Identification and characterization of the specific resonance ionization scheme applied within the particular geometry of the apparatus in use is needed. An analysis of the dependence of the specifications, specifically regarding the influence of the relative laser beam polarizations is presented here as an aspect, that could have a severe impact on isotope ratio precision and overall efficiency in the resulting ion signal.",
keywords = "Isotope ratio, Laser beam polarization, Plutonium, Resonance ionization, SNMS, Trace analysis",
author = "Hauke Bosco and Martin Weiss and Manuel Raiwa and Clemens Walther and Nina Kneip and Klaus Wendt",
note = "Funding Information: Open Access funding provided by Projekt DEAL. This work was supported by the Bundesministerium f{\"u}r Bildung und Forschung (BMBF, Germany), contract number 02NUK044A.",
year = "2020",
month = mar,
day = "3",
doi = "10.1007/s10751-020-1696-2",
language = "English",
volume = "241",

}

Download

TY - JOUR

T1 - Influence of the hyperfine structure on plutonium in resonant laser-SNMS

AU - Bosco, Hauke

AU - Weiss, Martin

AU - Raiwa, Manuel

AU - Walther, Clemens

AU - Kneip, Nina

AU - Wendt, Klaus

N1 - Funding Information: Open Access funding provided by Projekt DEAL. This work was supported by the Bundesministerium für Bildung und Forschung (BMBF, Germany), contract number 02NUK044A.

PY - 2020/3/3

Y1 - 2020/3/3

N2 - Resonance ionization mass spectrometry is an ultra-sensitive and highly element selective tool for spectroscopy, ionization and detection of atoms and thus enables rare isotope determination. In combination with spatially resolved sputtering of neutrals by an initial ion beam, e.g. within a commercial secondary ion mass spectrometer, an isotope and isobar selective analysis technique with resolution on the micrometer scale for particles and surfaces is realized. Detection of minuscule amounts of specific actinides, e.g. of plutonium, in environmental and technical samples by this ultra-trace analysis technique requires detailed knowledge about the atomic physics of the element. Identification and characterization of the specific resonance ionization scheme applied within the particular geometry of the apparatus in use is needed. An analysis of the dependence of the specifications, specifically regarding the influence of the relative laser beam polarizations is presented here as an aspect, that could have a severe impact on isotope ratio precision and overall efficiency in the resulting ion signal.

AB - Resonance ionization mass spectrometry is an ultra-sensitive and highly element selective tool for spectroscopy, ionization and detection of atoms and thus enables rare isotope determination. In combination with spatially resolved sputtering of neutrals by an initial ion beam, e.g. within a commercial secondary ion mass spectrometer, an isotope and isobar selective analysis technique with resolution on the micrometer scale for particles and surfaces is realized. Detection of minuscule amounts of specific actinides, e.g. of plutonium, in environmental and technical samples by this ultra-trace analysis technique requires detailed knowledge about the atomic physics of the element. Identification and characterization of the specific resonance ionization scheme applied within the particular geometry of the apparatus in use is needed. An analysis of the dependence of the specifications, specifically regarding the influence of the relative laser beam polarizations is presented here as an aspect, that could have a severe impact on isotope ratio precision and overall efficiency in the resulting ion signal.

KW - Isotope ratio

KW - Laser beam polarization

KW - Plutonium

KW - Resonance ionization

KW - SNMS

KW - Trace analysis

UR - http://www.scopus.com/inward/record.url?scp=85081031666&partnerID=8YFLogxK

U2 - 10.1007/s10751-020-1696-2

DO - 10.1007/s10751-020-1696-2

M3 - Article

AN - SCOPUS:85081031666

VL - 241

JO - Hyperfine Interactions

JF - Hyperfine Interactions

SN - 0304-3843

M1 - 34

ER -