Abstract

The potential of ultraviolet (UV) fluorescence as a field technique for photovoltaic module defect detection has been demonstrated recently. In the field during daytime, environmental parameters are not controllable. We assess in this work the influence of environmental temperature on the quality and reproducibility of UV fluorescence measurements. The kind of lamination material and its aging history very much influences the fluorescence intensity. During the measurement, the temperature of the module influences the fluorescence emission. A module at nominal operating cell temperature range (45°C to 50°C) can show from 3% up to 30% less fluorescence intensity compared to a module at a temperature of 25°C. The temperature dependence of the excitation UV light source itself has also some effect on the imaging quality but the influence of the camera temperature is negligible.

Keywords

    Fluorescence, nondestructive testing, solarmodule reliability

ASJC Scopus subject areas

Sustainable Development Goals

Cite this

Influence of environmental conditions on UV fluorescence imaging in the field. / Morlier, Arnaud; Siebert, Michael; Kunze, Iris et al.
2018. 1309-1312 Paper presented at 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018, Waikoloa Village, United States.

Research output: Contribution to conferencePaperResearchpeer review

Morlier, A, Siebert, M, Kunze, I, Blankemeyer, S & Köntges, M 2018, 'Influence of environmental conditions on UV fluorescence imaging in the field', Paper presented at 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018, Waikoloa Village, United States, 10 Jun 2018 - 15 Jun 2018 pp. 1309-1312. https://doi.org/10.1109/PVSC.2018.8547483
Morlier, A., Siebert, M., Kunze, I., Blankemeyer, S., & Köntges, M. (2018). Influence of environmental conditions on UV fluorescence imaging in the field. 1309-1312. Paper presented at 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018, Waikoloa Village, United States. https://doi.org/10.1109/PVSC.2018.8547483
Morlier A, Siebert M, Kunze I, Blankemeyer S, Köntges M. Influence of environmental conditions on UV fluorescence imaging in the field. 2018. Paper presented at 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018, Waikoloa Village, United States. doi: 10.1109/PVSC.2018.8547483
Morlier, Arnaud ; Siebert, Michael ; Kunze, Iris et al. / Influence of environmental conditions on UV fluorescence imaging in the field. Paper presented at 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018, Waikoloa Village, United States.4 p.
Download
@conference{32690e021ad54092af3a6196edfc2e68,
title = "Influence of environmental conditions on UV fluorescence imaging in the field",
abstract = "The potential of ultraviolet (UV) fluorescence as a field technique for photovoltaic module defect detection has been demonstrated recently. In the field during daytime, environmental parameters are not controllable. We assess in this work the influence of environmental temperature on the quality and reproducibility of UV fluorescence measurements. The kind of lamination material and its aging history very much influences the fluorescence intensity. During the measurement, the temperature of the module influences the fluorescence emission. A module at nominal operating cell temperature range (45°C to 50°C) can show from 3% up to 30% less fluorescence intensity compared to a module at a temperature of 25°C. The temperature dependence of the excitation UV light source itself has also some effect on the imaging quality but the influence of the camera temperature is negligible.",
keywords = "Fluorescence, nondestructive testing, solarmodule reliability",
author = "Arnaud Morlier and Michael Siebert and Iris Kunze and Susanne Blankemeyer and Marc K{\"o}ntges",
note = "Funding information: This work is funded by the German Federal Ministry for Economic Affairs and Energy (BMWi) under the funding contract number 0325735D.; 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018 ; Conference date: 10-06-2018 Through 15-06-2018",
year = "2018",
month = nov,
day = "26",
doi = "10.1109/PVSC.2018.8547483",
language = "English",
pages = "1309--1312",

}

Download

TY - CONF

T1 - Influence of environmental conditions on UV fluorescence imaging in the field

AU - Morlier, Arnaud

AU - Siebert, Michael

AU - Kunze, Iris

AU - Blankemeyer, Susanne

AU - Köntges, Marc

N1 - Funding information: This work is funded by the German Federal Ministry for Economic Affairs and Energy (BMWi) under the funding contract number 0325735D.

PY - 2018/11/26

Y1 - 2018/11/26

N2 - The potential of ultraviolet (UV) fluorescence as a field technique for photovoltaic module defect detection has been demonstrated recently. In the field during daytime, environmental parameters are not controllable. We assess in this work the influence of environmental temperature on the quality and reproducibility of UV fluorescence measurements. The kind of lamination material and its aging history very much influences the fluorescence intensity. During the measurement, the temperature of the module influences the fluorescence emission. A module at nominal operating cell temperature range (45°C to 50°C) can show from 3% up to 30% less fluorescence intensity compared to a module at a temperature of 25°C. The temperature dependence of the excitation UV light source itself has also some effect on the imaging quality but the influence of the camera temperature is negligible.

AB - The potential of ultraviolet (UV) fluorescence as a field technique for photovoltaic module defect detection has been demonstrated recently. In the field during daytime, environmental parameters are not controllable. We assess in this work the influence of environmental temperature on the quality and reproducibility of UV fluorescence measurements. The kind of lamination material and its aging history very much influences the fluorescence intensity. During the measurement, the temperature of the module influences the fluorescence emission. A module at nominal operating cell temperature range (45°C to 50°C) can show from 3% up to 30% less fluorescence intensity compared to a module at a temperature of 25°C. The temperature dependence of the excitation UV light source itself has also some effect on the imaging quality but the influence of the camera temperature is negligible.

KW - Fluorescence

KW - nondestructive testing

KW - solarmodule reliability

UR - http://www.scopus.com/inward/record.url?scp=85059904940&partnerID=8YFLogxK

U2 - 10.1109/PVSC.2018.8547483

DO - 10.1109/PVSC.2018.8547483

M3 - Paper

AN - SCOPUS:85059904940

SP - 1309

EP - 1312

T2 - 7th IEEE World Conference on Photovoltaic Energy Conversion, WCPEC 2018

Y2 - 10 June 2018 through 15 June 2018

ER -