High tilt susceptibility of the Scintrex CG-5 relative gravimeters

Research output: Contribution to journalArticleResearchpeer review

Authors

  • R. Reudink
  • R. Klees
  • O. Francis
  • J. Kusche
  • R. Schlesinger
  • A. Shabanloui
  • N. Sneeuw
  • L. Timmen

Research Organisations

External Research Organisations

  • Delft University of Technology
  • University of Luxembourg
  • University of Bonn
  • University of Stuttgart
View graph of relations

Details

Original languageEnglish
Pages (from-to)617-622
Number of pages6
JournalJournal of geodesy
Volume88
Issue number6
Publication statusPublished - Jun 2014

Abstract

We report on the susceptibility of the Scintrex CG-5 relative gravimeters to tilting, that is the tendency of the instrument of providing incorrect readings after being tilted (even by small angles) for a moderate period of time. Tilting of the instrument can occur when in transit between sites usually on the backseat of a car even using the specially designed transport case. Based on a series of experiments with different instruments, we demonstrate that the readings may be offset by tens of μGal. In addition, it may take hours before the first reliable readings can be taken, with the actual time depending on how long the instrument had been tilted. This sensitivity to tilt in combination with the long time required for the instrument to provide reliable readings has not yet been reported in the literature and is not addressed adequately in the Scintrex CG-5 user manual. In particular, the inadequate instrument state cannot easily be detected by checking the readings during the observation or by reviewing the final data before leaving a site, precautions suggested by Scintrex Ltd. In regional surveys with car transportation over periods of tens of minutes to hours, the gravity measurements can be degraded by some 10 μGal. To obtain high-quality results in line with the CG-5 specifications, the gravimeters must remain in upright position to within a few degrees during transits. This requirement may often be unrealistic during field observations, particularly when observing in hilly terrain or when walking with the instrument in a backpack.

Keywords

    Accuracy degradation, Hysteresis, Scintrex CG-5 autograv, Susceptibility to tilt, Tilt

ASJC Scopus subject areas

Cite this

High tilt susceptibility of the Scintrex CG-5 relative gravimeters. / Reudink, R.; Klees, R.; Francis, O. et al.
In: Journal of geodesy, Vol. 88, No. 6, 06.2014, p. 617-622.

Research output: Contribution to journalArticleResearchpeer review

Reudink, R, Klees, R, Francis, O, Kusche, J, Schlesinger, R, Shabanloui, A, Sneeuw, N & Timmen, L 2014, 'High tilt susceptibility of the Scintrex CG-5 relative gravimeters', Journal of geodesy, vol. 88, no. 6, pp. 617-622. https://doi.org/10.1007/s00190-014-0705-0
Reudink, R., Klees, R., Francis, O., Kusche, J., Schlesinger, R., Shabanloui, A., Sneeuw, N., & Timmen, L. (2014). High tilt susceptibility of the Scintrex CG-5 relative gravimeters. Journal of geodesy, 88(6), 617-622. https://doi.org/10.1007/s00190-014-0705-0
Reudink R, Klees R, Francis O, Kusche J, Schlesinger R, Shabanloui A et al. High tilt susceptibility of the Scintrex CG-5 relative gravimeters. Journal of geodesy. 2014 Jun;88(6):617-622. doi: 10.1007/s00190-014-0705-0
Reudink, R. ; Klees, R. ; Francis, O. et al. / High tilt susceptibility of the Scintrex CG-5 relative gravimeters. In: Journal of geodesy. 2014 ; Vol. 88, No. 6. pp. 617-622.
Download
@article{014eba6a387b432096780b772a749e5b,
title = "High tilt susceptibility of the Scintrex CG-5 relative gravimeters",
abstract = "We report on the susceptibility of the Scintrex CG-5 relative gravimeters to tilting, that is the tendency of the instrument of providing incorrect readings after being tilted (even by small angles) for a moderate period of time. Tilting of the instrument can occur when in transit between sites usually on the backseat of a car even using the specially designed transport case. Based on a series of experiments with different instruments, we demonstrate that the readings may be offset by tens of μGal. In addition, it may take hours before the first reliable readings can be taken, with the actual time depending on how long the instrument had been tilted. This sensitivity to tilt in combination with the long time required for the instrument to provide reliable readings has not yet been reported in the literature and is not addressed adequately in the Scintrex CG-5 user manual. In particular, the inadequate instrument state cannot easily be detected by checking the readings during the observation or by reviewing the final data before leaving a site, precautions suggested by Scintrex Ltd. In regional surveys with car transportation over periods of tens of minutes to hours, the gravity measurements can be degraded by some 10 μGal. To obtain high-quality results in line with the CG-5 specifications, the gravimeters must remain in upright position to within a few degrees during transits. This requirement may often be unrealistic during field observations, particularly when observing in hilly terrain or when walking with the instrument in a backpack.",
keywords = "Accuracy degradation, Hysteresis, Scintrex CG-5 autograv, Susceptibility to tilt, Tilt",
author = "R. Reudink and R. Klees and O. Francis and J. Kusche and R. Schlesinger and A. Shabanloui and N. Sneeuw and L. Timmen",
year = "2014",
month = jun,
doi = "10.1007/s00190-014-0705-0",
language = "English",
volume = "88",
pages = "617--622",
journal = "Journal of geodesy",
issn = "0949-7714",
publisher = "Springer Verlag",
number = "6",

}

Download

TY - JOUR

T1 - High tilt susceptibility of the Scintrex CG-5 relative gravimeters

AU - Reudink, R.

AU - Klees, R.

AU - Francis, O.

AU - Kusche, J.

AU - Schlesinger, R.

AU - Shabanloui, A.

AU - Sneeuw, N.

AU - Timmen, L.

PY - 2014/6

Y1 - 2014/6

N2 - We report on the susceptibility of the Scintrex CG-5 relative gravimeters to tilting, that is the tendency of the instrument of providing incorrect readings after being tilted (even by small angles) for a moderate period of time. Tilting of the instrument can occur when in transit between sites usually on the backseat of a car even using the specially designed transport case. Based on a series of experiments with different instruments, we demonstrate that the readings may be offset by tens of μGal. In addition, it may take hours before the first reliable readings can be taken, with the actual time depending on how long the instrument had been tilted. This sensitivity to tilt in combination with the long time required for the instrument to provide reliable readings has not yet been reported in the literature and is not addressed adequately in the Scintrex CG-5 user manual. In particular, the inadequate instrument state cannot easily be detected by checking the readings during the observation or by reviewing the final data before leaving a site, precautions suggested by Scintrex Ltd. In regional surveys with car transportation over periods of tens of minutes to hours, the gravity measurements can be degraded by some 10 μGal. To obtain high-quality results in line with the CG-5 specifications, the gravimeters must remain in upright position to within a few degrees during transits. This requirement may often be unrealistic during field observations, particularly when observing in hilly terrain or when walking with the instrument in a backpack.

AB - We report on the susceptibility of the Scintrex CG-5 relative gravimeters to tilting, that is the tendency of the instrument of providing incorrect readings after being tilted (even by small angles) for a moderate period of time. Tilting of the instrument can occur when in transit between sites usually on the backseat of a car even using the specially designed transport case. Based on a series of experiments with different instruments, we demonstrate that the readings may be offset by tens of μGal. In addition, it may take hours before the first reliable readings can be taken, with the actual time depending on how long the instrument had been tilted. This sensitivity to tilt in combination with the long time required for the instrument to provide reliable readings has not yet been reported in the literature and is not addressed adequately in the Scintrex CG-5 user manual. In particular, the inadequate instrument state cannot easily be detected by checking the readings during the observation or by reviewing the final data before leaving a site, precautions suggested by Scintrex Ltd. In regional surveys with car transportation over periods of tens of minutes to hours, the gravity measurements can be degraded by some 10 μGal. To obtain high-quality results in line with the CG-5 specifications, the gravimeters must remain in upright position to within a few degrees during transits. This requirement may often be unrealistic during field observations, particularly when observing in hilly terrain or when walking with the instrument in a backpack.

KW - Accuracy degradation

KW - Hysteresis

KW - Scintrex CG-5 autograv

KW - Susceptibility to tilt

KW - Tilt

UR - http://www.scopus.com/inward/record.url?scp=84901028758&partnerID=8YFLogxK

U2 - 10.1007/s00190-014-0705-0

DO - 10.1007/s00190-014-0705-0

M3 - Article

AN - SCOPUS:84901028758

VL - 88

SP - 617

EP - 622

JO - Journal of geodesy

JF - Journal of geodesy

SN - 0949-7714

IS - 6

ER -