Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren

Research output: Chapter in book/report/conference proceedingConference contributionResearch

Authors

  • Tobias Kinkeldey
  • Sebastian Schreiter
  • Holger Lohmeyer
  • Peter Werle
  • Tobias Münster
  • K. Hämel
  • J. Preusel

External Research Organisations

  • Leipzig University of Applied Sciences
  • ABB Group
  • GRIDINSPECT GmbH
View graph of relations

Details

Translated title of the contributionFuran concentrations vs. fuzzy logic: A new proposal for the estimation of the DP value of power transformers
Original languageGerman
Title of host publicationVDE Hochspannungstechnik
PublisherVDE Verlag GmbH
Pages406-411
Number of pages6
ISBN (electronic)978-3-8007-5355-0
ISBN (print)978-3-8007-5353-6
Publication statusPublished - 2020
EventVDE High Voltage Technology 2020 - Virtual, Online, Germany
Duration: 9 Nov 202011 Nov 2020

Publication series

NameETG-Fachberichte
Volume162

Abstract

Transformers belong to the most valuable equipment in the electrical power supply. It is therefore of elementary interest for operators of transformers to estimate the remaining service life of this equipment. The average degree of polymerisation (DP value) is taken as an indicator of ageing, which is a measure of the average remaining chain length of the cellulose molecules. This value can be determined from a paper sample by chemical analysis. Unfortunately, it is almost impossible to obtain such a paper sample during operation or during short shutdowns, as this requires intervention in the transformer's insulation system. Therefore the development of methods to draw conclusions about the quality of the solid component on the basis of easily accessible oil parameters is subject of scientific discussion. An established method is the estimation of the DP-value on the basis of the furan concentrations in the insulating liquid by means of equilibrium curves. However, investigations show that these estimates of the DP value based on the furan concentrations in real transformers often do not indicate the true state. However, since the ageing of the equipment is also accompanied by the deterioration of other parameters such as oil and gas parameters, this paper will discuss the potential of interpreting these physically independent parameters to provide a condition statement using special developed fuzzy logic algorithms.

ASJC Scopus subject areas

Cite this

Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren. / Kinkeldey, Tobias; Schreiter, Sebastian; Lohmeyer, Holger et al.
VDE Hochspannungstechnik. VDE Verlag GmbH, 2020. p. 406-411 (ETG-Fachberichte; Vol. 162).

Research output: Chapter in book/report/conference proceedingConference contributionResearch

Kinkeldey, T, Schreiter, S, Lohmeyer, H, Werle, P, Münster, T, Hämel, K & Preusel, J 2020, Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren. in VDE Hochspannungstechnik. ETG-Fachberichte, vol. 162, VDE Verlag GmbH, pp. 406-411, VDE High Voltage Technology 2020, Virtual, Online, Germany, 9 Nov 2020.
Kinkeldey, T., Schreiter, S., Lohmeyer, H., Werle, P., Münster, T., Hämel, K., & Preusel, J. (2020). Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren. In VDE Hochspannungstechnik (pp. 406-411). (ETG-Fachberichte; Vol. 162). VDE Verlag GmbH.
Kinkeldey T, Schreiter S, Lohmeyer H, Werle P, Münster T, Hämel K et al. Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren. In VDE Hochspannungstechnik. VDE Verlag GmbH. 2020. p. 406-411. (ETG-Fachberichte).
Kinkeldey, Tobias ; Schreiter, Sebastian ; Lohmeyer, Holger et al. / Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren. VDE Hochspannungstechnik. VDE Verlag GmbH, 2020. pp. 406-411 (ETG-Fachberichte).
Download
@inproceedings{d81d41393a9948b3af4c4b008a6e6005,
title = "Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Absch{\"a}tzung des DP-Wertes von Leistungstransformatoren",
abstract = "Transformers belong to the most valuable equipment in the electrical power supply. It is therefore of elementary interest for operators of transformers to estimate the remaining service life of this equipment. The average degree of polymerisation (DP value) is taken as an indicator of ageing, which is a measure of the average remaining chain length of the cellulose molecules. This value can be determined from a paper sample by chemical analysis. Unfortunately, it is almost impossible to obtain such a paper sample during operation or during short shutdowns, as this requires intervention in the transformer's insulation system. Therefore the development of methods to draw conclusions about the quality of the solid component on the basis of easily accessible oil parameters is subject of scientific discussion. An established method is the estimation of the DP-value on the basis of the furan concentrations in the insulating liquid by means of equilibrium curves. However, investigations show that these estimates of the DP value based on the furan concentrations in real transformers often do not indicate the true state. However, since the ageing of the equipment is also accompanied by the deterioration of other parameters such as oil and gas parameters, this paper will discuss the potential of interpreting these physically independent parameters to provide a condition statement using special developed fuzzy logic algorithms.",
author = "Tobias Kinkeldey and Sebastian Schreiter and Holger Lohmeyer and Peter Werle and Tobias M{\"u}nster and K. H{\"a}mel and J. Preusel",
year = "2020",
language = "Deutsch",
isbn = "978-3-8007-5353-6",
series = "ETG-Fachberichte",
publisher = "VDE Verlag GmbH",
pages = "406--411",
booktitle = "VDE Hochspannungstechnik",
address = "Deutschland",
note = "VDE High Voltage Technology 2020 ; Conference date: 09-11-2020 Through 11-11-2020",

}

Download

TY - GEN

T1 - Furankonzentrationen vs. Fuzzy-Logik: Ein neuer Vorschlag zu Abschätzung des DP-Wertes von Leistungstransformatoren

AU - Kinkeldey, Tobias

AU - Schreiter, Sebastian

AU - Lohmeyer, Holger

AU - Werle, Peter

AU - Münster, Tobias

AU - Hämel, K.

AU - Preusel, J.

PY - 2020

Y1 - 2020

N2 - Transformers belong to the most valuable equipment in the electrical power supply. It is therefore of elementary interest for operators of transformers to estimate the remaining service life of this equipment. The average degree of polymerisation (DP value) is taken as an indicator of ageing, which is a measure of the average remaining chain length of the cellulose molecules. This value can be determined from a paper sample by chemical analysis. Unfortunately, it is almost impossible to obtain such a paper sample during operation or during short shutdowns, as this requires intervention in the transformer's insulation system. Therefore the development of methods to draw conclusions about the quality of the solid component on the basis of easily accessible oil parameters is subject of scientific discussion. An established method is the estimation of the DP-value on the basis of the furan concentrations in the insulating liquid by means of equilibrium curves. However, investigations show that these estimates of the DP value based on the furan concentrations in real transformers often do not indicate the true state. However, since the ageing of the equipment is also accompanied by the deterioration of other parameters such as oil and gas parameters, this paper will discuss the potential of interpreting these physically independent parameters to provide a condition statement using special developed fuzzy logic algorithms.

AB - Transformers belong to the most valuable equipment in the electrical power supply. It is therefore of elementary interest for operators of transformers to estimate the remaining service life of this equipment. The average degree of polymerisation (DP value) is taken as an indicator of ageing, which is a measure of the average remaining chain length of the cellulose molecules. This value can be determined from a paper sample by chemical analysis. Unfortunately, it is almost impossible to obtain such a paper sample during operation or during short shutdowns, as this requires intervention in the transformer's insulation system. Therefore the development of methods to draw conclusions about the quality of the solid component on the basis of easily accessible oil parameters is subject of scientific discussion. An established method is the estimation of the DP-value on the basis of the furan concentrations in the insulating liquid by means of equilibrium curves. However, investigations show that these estimates of the DP value based on the furan concentrations in real transformers often do not indicate the true state. However, since the ageing of the equipment is also accompanied by the deterioration of other parameters such as oil and gas parameters, this paper will discuss the potential of interpreting these physically independent parameters to provide a condition statement using special developed fuzzy logic algorithms.

UR - http://www.scopus.com/inward/record.url?scp=85101692554&partnerID=8YFLogxK

M3 - Aufsatz in Konferenzband

SN - 978-3-8007-5353-6

T3 - ETG-Fachberichte

SP - 406

EP - 411

BT - VDE Hochspannungstechnik

PB - VDE Verlag GmbH

T2 - VDE High Voltage Technology 2020

Y2 - 9 November 2020 through 11 November 2020

ER -

By the same author(s)