From ultraslow to fast lithium diffusion in the 2D ion conductor Li0.7TiS2 probed directly by stimulated-echo NMR and nuclear magnetic relaxation

Research output: Contribution to journalArticleResearchpeer review

Authors

View graph of relations

Details

Original languageEnglish
Article number065901
JournalPhysical review letters
Volume97
Issue number6
Publication statusPublished - 2006

Abstract

Li7 stimulated-echo NMR and classical relaxation NMR techniques are jointly used for the first time for a comprehensive investigation of Li diffusion in layer-structured Li0.7TiS2. One single 2D Li diffusion process was probed over a dynamic range of almost 10 orders of magnitude. So far, this is the largest dynamic range being measured by Li7 NMR spectroscopy directly, i.e., without the help of a specific theoretical model. The jump rates obey a strict Arrhenius law, determined by an activation energy of 0.41(1)eV and a preexponential factor of 6.3(1)×1012s-1, and range between 1×10-1s-1 and 7.8×108s-1 (148-510K). Ultraslow Li jumps in the kHz to sub-Hz range were measured directly by recording Li7 spin-alignment correlation functions. The temperature and, in particular, the frequency dependence of the relaxation rates fully agree with results expected for 2D diffusion.

ASJC Scopus subject areas

Cite this

From ultraslow to fast lithium diffusion in the 2D ion conductor Li0.7TiS2 probed directly by stimulated-echo NMR and nuclear magnetic relaxation. / Wilkening, M.; Küchler, W.; Heitjans, P.
In: Physical review letters, Vol. 97, No. 6, 065901, 2006.

Research output: Contribution to journalArticleResearchpeer review

Download
@article{18a70954e22c4d58911b003073dc15f7,
title = "From ultraslow to fast lithium diffusion in the 2D ion conductor Li0.7TiS2 probed directly by stimulated-echo NMR and nuclear magnetic relaxation",
abstract = "Li7 stimulated-echo NMR and classical relaxation NMR techniques are jointly used for the first time for a comprehensive investigation of Li diffusion in layer-structured Li0.7TiS2. One single 2D Li diffusion process was probed over a dynamic range of almost 10 orders of magnitude. So far, this is the largest dynamic range being measured by Li7 NMR spectroscopy directly, i.e., without the help of a specific theoretical model. The jump rates obey a strict Arrhenius law, determined by an activation energy of 0.41(1)eV and a preexponential factor of 6.3(1)×1012s-1, and range between 1×10-1s-1 and 7.8×108s-1 (148-510K). Ultraslow Li jumps in the kHz to sub-Hz range were measured directly by recording Li7 spin-alignment correlation functions. The temperature and, in particular, the frequency dependence of the relaxation rates fully agree with results expected for 2D diffusion.",
author = "M. Wilkening and W. K{\"u}chler and P. Heitjans",
year = "2006",
doi = "10.1103/PhysRevLett.97.065901",
language = "English",
volume = "97",
journal = "Physical review letters",
issn = "0031-9007",
publisher = "American Physical Society",
number = "6",

}

Download

TY - JOUR

T1 - From ultraslow to fast lithium diffusion in the 2D ion conductor Li0.7TiS2 probed directly by stimulated-echo NMR and nuclear magnetic relaxation

AU - Wilkening, M.

AU - Küchler, W.

AU - Heitjans, P.

PY - 2006

Y1 - 2006

N2 - Li7 stimulated-echo NMR and classical relaxation NMR techniques are jointly used for the first time for a comprehensive investigation of Li diffusion in layer-structured Li0.7TiS2. One single 2D Li diffusion process was probed over a dynamic range of almost 10 orders of magnitude. So far, this is the largest dynamic range being measured by Li7 NMR spectroscopy directly, i.e., without the help of a specific theoretical model. The jump rates obey a strict Arrhenius law, determined by an activation energy of 0.41(1)eV and a preexponential factor of 6.3(1)×1012s-1, and range between 1×10-1s-1 and 7.8×108s-1 (148-510K). Ultraslow Li jumps in the kHz to sub-Hz range were measured directly by recording Li7 spin-alignment correlation functions. The temperature and, in particular, the frequency dependence of the relaxation rates fully agree with results expected for 2D diffusion.

AB - Li7 stimulated-echo NMR and classical relaxation NMR techniques are jointly used for the first time for a comprehensive investigation of Li diffusion in layer-structured Li0.7TiS2. One single 2D Li diffusion process was probed over a dynamic range of almost 10 orders of magnitude. So far, this is the largest dynamic range being measured by Li7 NMR spectroscopy directly, i.e., without the help of a specific theoretical model. The jump rates obey a strict Arrhenius law, determined by an activation energy of 0.41(1)eV and a preexponential factor of 6.3(1)×1012s-1, and range between 1×10-1s-1 and 7.8×108s-1 (148-510K). Ultraslow Li jumps in the kHz to sub-Hz range were measured directly by recording Li7 spin-alignment correlation functions. The temperature and, in particular, the frequency dependence of the relaxation rates fully agree with results expected for 2D diffusion.

UR - http://www.scopus.com/inward/record.url?scp=33747056611&partnerID=8YFLogxK

U2 - 10.1103/PhysRevLett.97.065901

DO - 10.1103/PhysRevLett.97.065901

M3 - Article

AN - SCOPUS:33747056611

VL - 97

JO - Physical review letters

JF - Physical review letters

SN - 0031-9007

IS - 6

M1 - 065901

ER -

By the same author(s)