Frequency response of Michelson- and Sagnac-based interferometers

Research output: Contribution to journalArticleResearchpeer review

Authors

  • J. Mizuno
  • A. Rüdiger
  • R. Schilling
  • W. Winkler
  • K. Danzmann

External Research Organisations

  • Max Planck Institute of Quantum Optics (MPQ)
View graph of relations

Details

Original languageEnglish
Pages (from-to)383-393
Number of pages11
JournalOptics communications
Volume138
Issue number4-6
Publication statusPublished - 1 Jun 1997
Externally publishedYes

Abstract

The frequency response of Michelson- and Sagnac-based interferometers are evaluated and compared, considering the application for gravitational-wave detection. It is shown that Sagnac-based interferometers have some interesting features, but in general do not offer advantages over Michel son-based ones for the detection of gravitational waves.

Keywords

    Gravitational wave detector, Michelson interferometer, Power recycling, Resonant sideband extraction, Sagnac interferometer, Signal recycling

ASJC Scopus subject areas

Cite this

Frequency response of Michelson- and Sagnac-based interferometers. / Mizuno, J.; Rüdiger, A.; Schilling, R. et al.
In: Optics communications, Vol. 138, No. 4-6, 01.06.1997, p. 383-393.

Research output: Contribution to journalArticleResearchpeer review

Mizuno, J, Rüdiger, A, Schilling, R, Winkler, W & Danzmann, K 1997, 'Frequency response of Michelson- and Sagnac-based interferometers', Optics communications, vol. 138, no. 4-6, pp. 383-393. https://doi.org/10.1016/S0030-4018(97)00056-4
Mizuno, J., Rüdiger, A., Schilling, R., Winkler, W., & Danzmann, K. (1997). Frequency response of Michelson- and Sagnac-based interferometers. Optics communications, 138(4-6), 383-393. https://doi.org/10.1016/S0030-4018(97)00056-4
Mizuno J, Rüdiger A, Schilling R, Winkler W, Danzmann K. Frequency response of Michelson- and Sagnac-based interferometers. Optics communications. 1997 Jun 1;138(4-6):383-393. doi: 10.1016/S0030-4018(97)00056-4
Mizuno, J. ; Rüdiger, A. ; Schilling, R. et al. / Frequency response of Michelson- and Sagnac-based interferometers. In: Optics communications. 1997 ; Vol. 138, No. 4-6. pp. 383-393.
Download
@article{96d25e41a0c74fbea2c54c491c125389,
title = "Frequency response of Michelson- and Sagnac-based interferometers",
abstract = "The frequency response of Michelson- and Sagnac-based interferometers are evaluated and compared, considering the application for gravitational-wave detection. It is shown that Sagnac-based interferometers have some interesting features, but in general do not offer advantages over Michel son-based ones for the detection of gravitational waves.",
keywords = "Gravitational wave detector, Michelson interferometer, Power recycling, Resonant sideband extraction, Sagnac interferometer, Signal recycling",
author = "J. Mizuno and A. R{\"u}diger and R. Schilling and W. Winkler and K. Danzmann",
year = "1997",
month = jun,
day = "1",
doi = "10.1016/S0030-4018(97)00056-4",
language = "English",
volume = "138",
pages = "383--393",
journal = "Optics communications",
issn = "0030-4018",
publisher = "Elsevier",
number = "4-6",

}

Download

TY - JOUR

T1 - Frequency response of Michelson- and Sagnac-based interferometers

AU - Mizuno, J.

AU - Rüdiger, A.

AU - Schilling, R.

AU - Winkler, W.

AU - Danzmann, K.

PY - 1997/6/1

Y1 - 1997/6/1

N2 - The frequency response of Michelson- and Sagnac-based interferometers are evaluated and compared, considering the application for gravitational-wave detection. It is shown that Sagnac-based interferometers have some interesting features, but in general do not offer advantages over Michel son-based ones for the detection of gravitational waves.

AB - The frequency response of Michelson- and Sagnac-based interferometers are evaluated and compared, considering the application for gravitational-wave detection. It is shown that Sagnac-based interferometers have some interesting features, but in general do not offer advantages over Michel son-based ones for the detection of gravitational waves.

KW - Gravitational wave detector

KW - Michelson interferometer

KW - Power recycling

KW - Resonant sideband extraction

KW - Sagnac interferometer

KW - Signal recycling

UR - http://www.scopus.com/inward/record.url?scp=0031165580&partnerID=8YFLogxK

U2 - 10.1016/S0030-4018(97)00056-4

DO - 10.1016/S0030-4018(97)00056-4

M3 - Article

AN - SCOPUS:0031165580

VL - 138

SP - 383

EP - 393

JO - Optics communications

JF - Optics communications

SN - 0030-4018

IS - 4-6

ER -