Details
Original language | English |
---|---|
Title of host publication | ICHVE 2012 - 2012 International Conference on High Voltage Engineering and Application |
Pages | 476-479 |
Number of pages | 4 |
Publication status | Published - 2012 |
Event | 2012 International Conference on High Voltage Engineering and Application, ICHVE 2012 - Shanghai, China Duration: 17 Sept 2012 → 20 Sept 2012 |
Publication series
Name | ICHVE 2012 - 2012 International Conference on High Voltage Engineering and Application |
---|
Abstract
The Frequency Response Analysis (FRA) is considered as an useful measure to detect deformation and changes of the active part of transformers. However, the corresponding interpretation is still subject of different investigation as there are many questions to be answered.
ASJC Scopus subject areas
- Engineering(all)
- Electrical and Electronic Engineering
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
ICHVE 2012 - 2012 International Conference on High Voltage Engineering and Application. 2012. p. 476-479 6357083 (ICHVE 2012 - 2012 International Conference on High Voltage Engineering and Application).
Research output: Chapter in book/report/conference proceeding › Conference contribution › Research › peer review
}
TY - GEN
T1 - FRA-based transformer parameters at low frequencies
AU - Pham, D. A.K.
AU - Pham, T. M.T.
AU - Safari, M. H.
AU - Ho, V. N.C.
AU - Borsi, H.
AU - Gockenbach, Ernst
N1 - Copyright: Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2012
Y1 - 2012
N2 - The Frequency Response Analysis (FRA) is considered as an useful measure to detect deformation and changes of the active part of transformers. However, the corresponding interpretation is still subject of different investigation as there are many questions to be answered.
AB - The Frequency Response Analysis (FRA) is considered as an useful measure to detect deformation and changes of the active part of transformers. However, the corresponding interpretation is still subject of different investigation as there are many questions to be answered.
UR - http://www.scopus.com/inward/record.url?scp=84871563372&partnerID=8YFLogxK
U2 - 10.1109/ICHVE.2012.6357083
DO - 10.1109/ICHVE.2012.6357083
M3 - Conference contribution
AN - SCOPUS:84871563372
SN - 9781467347464
T3 - ICHVE 2012 - 2012 International Conference on High Voltage Engineering and Application
SP - 476
EP - 479
BT - ICHVE 2012 - 2012 International Conference on High Voltage Engineering and Application
T2 - 2012 International Conference on High Voltage Engineering and Application, ICHVE 2012
Y2 - 17 September 2012 through 20 September 2012
ER -