First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory

Research output: Contribution to journalArticleResearchpeer review

Authors

  • H. Grote
  • K. Danzmann
  • K. L. Dooley
  • R. Schnabel
  • J. Slutsky
  • H. Vahlbruch

Research Organisations

External Research Organisations

  • Max Planck Institute for Gravitational Physics (Albert Einstein Institute)
View graph of relations

Details

Original languageEnglish
Article number181101
JournalPhysical review letters
Volume110
Issue number18
Publication statusPublished - 3 May 2013

Abstract

We report on the first long-term application of squeezed vacuum states of light to improve the shot-noise-limited sensitivity of a gravitational-wave observatory. In particular, squeezed vacuum was applied to the German-British detector GEO 600 during a period of three months from June to August 2011, when GEO 600 was performing an observational run together with the French-Italian Virgo detector. In a second period, the squeezing application continued for about 11 months from November 2011 to October 2012. During this time, squeezed vacuum was applied for 90.2% (205.2 days total) of the time that science-quality data were acquired with GEO 600. A sensitivity increase from squeezed vacuum application was observed broadband above 400 Hz. The time average of gain in sensitivity was 26% (2.0 dB), determined in the frequency band from 3.7 to 4.0 kHz. This corresponds to a factor of 2 increase in the observed volume of the Universe for sources in the kHz region (e.g., supernovae, magnetars). We introduce three new techniques to enable the long-term application of squeezed light, and show that the glitch rate of the detector did not increase from squeezing application. Squeezed vacuum states of light have arrived as a permanent application, capable of increasing the astrophysical reach of gravitational-wave detectors.

ASJC Scopus subject areas

Cite this

First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory. / Grote, H.; Danzmann, K.; Dooley, K. L. et al.
In: Physical review letters, Vol. 110, No. 18, 181101, 03.05.2013.

Research output: Contribution to journalArticleResearchpeer review

Grote, H, Danzmann, K, Dooley, KL, Schnabel, R, Slutsky, J & Vahlbruch, H 2013, 'First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory', Physical review letters, vol. 110, no. 18, 181101. https://doi.org/10.1103/PhysRevLett.110.181101
Grote, H., Danzmann, K., Dooley, K. L., Schnabel, R., Slutsky, J., & Vahlbruch, H. (2013). First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory. Physical review letters, 110(18), Article 181101. https://doi.org/10.1103/PhysRevLett.110.181101
Grote H, Danzmann K, Dooley KL, Schnabel R, Slutsky J, Vahlbruch H. First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory. Physical review letters. 2013 May 3;110(18):181101. doi: 10.1103/PhysRevLett.110.181101
Grote, H. ; Danzmann, K. ; Dooley, K. L. et al. / First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory. In: Physical review letters. 2013 ; Vol. 110, No. 18.
Download
@article{114ae8b5f6dd4b6092b226005a662c3b,
title = "First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory",
abstract = "We report on the first long-term application of squeezed vacuum states of light to improve the shot-noise-limited sensitivity of a gravitational-wave observatory. In particular, squeezed vacuum was applied to the German-British detector GEO 600 during a period of three months from June to August 2011, when GEO 600 was performing an observational run together with the French-Italian Virgo detector. In a second period, the squeezing application continued for about 11 months from November 2011 to October 2012. During this time, squeezed vacuum was applied for 90.2% (205.2 days total) of the time that science-quality data were acquired with GEO 600. A sensitivity increase from squeezed vacuum application was observed broadband above 400 Hz. The time average of gain in sensitivity was 26% (2.0 dB), determined in the frequency band from 3.7 to 4.0 kHz. This corresponds to a factor of 2 increase in the observed volume of the Universe for sources in the kHz region (e.g., supernovae, magnetars). We introduce three new techniques to enable the long-term application of squeezed light, and show that the glitch rate of the detector did not increase from squeezing application. Squeezed vacuum states of light have arrived as a permanent application, capable of increasing the astrophysical reach of gravitational-wave detectors.",
author = "H. Grote and K. Danzmann and Dooley, {K. L.} and R. Schnabel and J. Slutsky and H. Vahlbruch",
year = "2013",
month = may,
day = "3",
doi = "10.1103/PhysRevLett.110.181101",
language = "English",
volume = "110",
journal = "Physical review letters",
issn = "0031-9007",
publisher = "American Physical Society",
number = "18",

}

Download

TY - JOUR

T1 - First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory

AU - Grote, H.

AU - Danzmann, K.

AU - Dooley, K. L.

AU - Schnabel, R.

AU - Slutsky, J.

AU - Vahlbruch, H.

PY - 2013/5/3

Y1 - 2013/5/3

N2 - We report on the first long-term application of squeezed vacuum states of light to improve the shot-noise-limited sensitivity of a gravitational-wave observatory. In particular, squeezed vacuum was applied to the German-British detector GEO 600 during a period of three months from June to August 2011, when GEO 600 was performing an observational run together with the French-Italian Virgo detector. In a second period, the squeezing application continued for about 11 months from November 2011 to October 2012. During this time, squeezed vacuum was applied for 90.2% (205.2 days total) of the time that science-quality data were acquired with GEO 600. A sensitivity increase from squeezed vacuum application was observed broadband above 400 Hz. The time average of gain in sensitivity was 26% (2.0 dB), determined in the frequency band from 3.7 to 4.0 kHz. This corresponds to a factor of 2 increase in the observed volume of the Universe for sources in the kHz region (e.g., supernovae, magnetars). We introduce three new techniques to enable the long-term application of squeezed light, and show that the glitch rate of the detector did not increase from squeezing application. Squeezed vacuum states of light have arrived as a permanent application, capable of increasing the astrophysical reach of gravitational-wave detectors.

AB - We report on the first long-term application of squeezed vacuum states of light to improve the shot-noise-limited sensitivity of a gravitational-wave observatory. In particular, squeezed vacuum was applied to the German-British detector GEO 600 during a period of three months from June to August 2011, when GEO 600 was performing an observational run together with the French-Italian Virgo detector. In a second period, the squeezing application continued for about 11 months from November 2011 to October 2012. During this time, squeezed vacuum was applied for 90.2% (205.2 days total) of the time that science-quality data were acquired with GEO 600. A sensitivity increase from squeezed vacuum application was observed broadband above 400 Hz. The time average of gain in sensitivity was 26% (2.0 dB), determined in the frequency band from 3.7 to 4.0 kHz. This corresponds to a factor of 2 increase in the observed volume of the Universe for sources in the kHz region (e.g., supernovae, magnetars). We introduce three new techniques to enable the long-term application of squeezed light, and show that the glitch rate of the detector did not increase from squeezing application. Squeezed vacuum states of light have arrived as a permanent application, capable of increasing the astrophysical reach of gravitational-wave detectors.

UR - http://www.scopus.com/inward/record.url?scp=84877727267&partnerID=8YFLogxK

U2 - 10.1103/PhysRevLett.110.181101

DO - 10.1103/PhysRevLett.110.181101

M3 - Article

AN - SCOPUS:84877727267

VL - 110

JO - Physical review letters

JF - Physical review letters

SN - 0031-9007

IS - 18

M1 - 181101

ER -