Experimental studies on the disappearance of subretinal fluid after episcleral buckling procedures without drainage

Research output: Contribution to journalArticleResearchpeer review

Authors

External Research Organisations

  • University of Münster
View graph of relations

Details

Original languageEnglish
Pages (from-to)16-18
Number of pages3
JournalGraefes Archive for Clinical and Experimental Ophthalmology
Volume225
Issue number1
Publication statusPublished - 1987

Abstract

We have developed an experimental model to show that an additional mechanism apart from absorption by pigment epithelium is responsible for the absorption of subretinal fluid. The cause of a fast diminution of subretinal fluid after a buckling procedure is the prominence of the buckle as an obstacle to fluid movements in the eye. This results in any fluid being pushed through the retinal hole into the vitreous. When the retinal hole is closed by the buckle, the remaining part of the subretinal fluid is slowly absorbed by the pigment epithelium present. We performed a preliminary qualitative and quantitative analysis of the phenomena occurring using the finite element method of Zienkiewicz.

ASJC Scopus subject areas

Cite this

Experimental studies on the disappearance of subretinal fluid after episcleral buckling procedures without drainage. / Clemens, S.; Stein, E.; Wagner, W. et al.
In: Graefes Archive for Clinical and Experimental Ophthalmology, Vol. 225, No. 1, 1987, p. 16-18.

Research output: Contribution to journalArticleResearchpeer review

Download
@article{454a127a6f984776899a2a9ea928a5d8,
title = "Experimental studies on the disappearance of subretinal fluid after episcleral buckling procedures without drainage",
abstract = "We have developed an experimental model to show that an additional mechanism apart from absorption by pigment epithelium is responsible for the absorption of subretinal fluid. The cause of a fast diminution of subretinal fluid after a buckling procedure is the prominence of the buckle as an obstacle to fluid movements in the eye. This results in any fluid being pushed through the retinal hole into the vitreous. When the retinal hole is closed by the buckle, the remaining part of the subretinal fluid is slowly absorbed by the pigment epithelium present. We performed a preliminary qualitative and quantitative analysis of the phenomena occurring using the finite element method of Zienkiewicz.",
author = "S. Clemens and E. Stein and W. Wagner and Peter Wriggers and P. Kroll",
year = "1987",
doi = "10.1007/BF02155798",
language = "English",
volume = "225",
pages = "16--18",
journal = "Graefes Archive for Clinical and Experimental Ophthalmology",
issn = "0721-832X",
publisher = "Springer Verlag",
number = "1",

}

Download

TY - JOUR

T1 - Experimental studies on the disappearance of subretinal fluid after episcleral buckling procedures without drainage

AU - Clemens, S.

AU - Stein, E.

AU - Wagner, W.

AU - Wriggers, Peter

AU - Kroll, P.

PY - 1987

Y1 - 1987

N2 - We have developed an experimental model to show that an additional mechanism apart from absorption by pigment epithelium is responsible for the absorption of subretinal fluid. The cause of a fast diminution of subretinal fluid after a buckling procedure is the prominence of the buckle as an obstacle to fluid movements in the eye. This results in any fluid being pushed through the retinal hole into the vitreous. When the retinal hole is closed by the buckle, the remaining part of the subretinal fluid is slowly absorbed by the pigment epithelium present. We performed a preliminary qualitative and quantitative analysis of the phenomena occurring using the finite element method of Zienkiewicz.

AB - We have developed an experimental model to show that an additional mechanism apart from absorption by pigment epithelium is responsible for the absorption of subretinal fluid. The cause of a fast diminution of subretinal fluid after a buckling procedure is the prominence of the buckle as an obstacle to fluid movements in the eye. This results in any fluid being pushed through the retinal hole into the vitreous. When the retinal hole is closed by the buckle, the remaining part of the subretinal fluid is slowly absorbed by the pigment epithelium present. We performed a preliminary qualitative and quantitative analysis of the phenomena occurring using the finite element method of Zienkiewicz.

UR - http://www.scopus.com/inward/record.url?scp=0022907641&partnerID=8YFLogxK

U2 - 10.1007/BF02155798

DO - 10.1007/BF02155798

M3 - Article

C2 - 3569945

AN - SCOPUS:0022907641

VL - 225

SP - 16

EP - 18

JO - Graefes Archive for Clinical and Experimental Ophthalmology

JF - Graefes Archive for Clinical and Experimental Ophthalmology

SN - 0721-832X

IS - 1

ER -

By the same author(s)