Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines

Research output: Contribution to journalConference articleResearchpeer review

Authors

  • Mohsen Farahani
  • H. Borsi
  • E. Gockenbach
View graph of relations

Details

Original languageEnglish
Pages (from-to)454-457
Number of pages4
JournalConference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report
Publication statusPublished - 2002
Event2002 IEEE Conference on Electrical Insulation and Dielectric Phenomena - Cancun, Mexico
Duration: 20 Oct 200224 Oct 2002

Abstract

The possibilities and limitations of partial discharge (PD), recovery voltage (RV) and dissipation factor measurement for evaluation of the actual status of insulation system of high voltage rotation machines were presented. The dielectric dissipation of insulation was found to cause by insulation resistance and relaxation polarization alongwith the interface polarization and partial discharges. The results confirmed the sensitivity of partial discharge measurement on the thermal ageing.

ASJC Scopus subject areas

Cite this

Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines. / Farahani, Mohsen; Borsi, H.; Gockenbach, E.
In: Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report, 2002, p. 454-457.

Research output: Contribution to journalConference articleResearchpeer review

Farahani, M, Borsi, H & Gockenbach, E 2002, 'Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines', Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report, pp. 454-457.
Farahani, M., Borsi, H., & Gockenbach, E. (2002). Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines. Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report, 454-457.
Farahani M, Borsi H, Gockenbach E. Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines. Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report. 2002;454-457.
Farahani, Mohsen ; Borsi, H. ; Gockenbach, E. / Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines. In: Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report. 2002 ; pp. 454-457.
Download
@article{f638c0724ff7467298229600f8f5026a,
title = "Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines",
abstract = "The possibilities and limitations of partial discharge (PD), recovery voltage (RV) and dissipation factor measurement for evaluation of the actual status of insulation system of high voltage rotation machines were presented. The dielectric dissipation of insulation was found to cause by insulation resistance and relaxation polarization alongwith the interface polarization and partial discharges. The results confirmed the sensitivity of partial discharge measurement on the thermal ageing.",
author = "Mohsen Farahani and H. Borsi and E. Gockenbach",
year = "2002",
language = "English",
pages = "454--457",
note = "2002 IEEE Conference on Electrical Insulation and Dielectric Phenomena ; Conference date: 20-10-2002 Through 24-10-2002",

}

Download

TY - JOUR

T1 - Experience with partial discharge, dissipation factor and recovery voltage measurements for the evaluation of insulation systems of high voltage rotating machines

AU - Farahani, Mohsen

AU - Borsi, H.

AU - Gockenbach, E.

PY - 2002

Y1 - 2002

N2 - The possibilities and limitations of partial discharge (PD), recovery voltage (RV) and dissipation factor measurement for evaluation of the actual status of insulation system of high voltage rotation machines were presented. The dielectric dissipation of insulation was found to cause by insulation resistance and relaxation polarization alongwith the interface polarization and partial discharges. The results confirmed the sensitivity of partial discharge measurement on the thermal ageing.

AB - The possibilities and limitations of partial discharge (PD), recovery voltage (RV) and dissipation factor measurement for evaluation of the actual status of insulation system of high voltage rotation machines were presented. The dielectric dissipation of insulation was found to cause by insulation resistance and relaxation polarization alongwith the interface polarization and partial discharges. The results confirmed the sensitivity of partial discharge measurement on the thermal ageing.

UR - http://www.scopus.com/inward/record.url?scp=0036442715&partnerID=8YFLogxK

M3 - Conference article

AN - SCOPUS:0036442715

SP - 454

EP - 457

JO - Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report

JF - Conference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report

SN - 0084-9162

T2 - 2002 IEEE Conference on Electrical Insulation and Dielectric Phenomena

Y2 - 20 October 2002 through 24 October 2002

ER -