Details
Original language | English |
---|---|
Pages (from-to) | 146-153 |
Number of pages | 8 |
Journal | IET Science, Measurement and Technology |
Volume | 2 |
Issue number | 3 |
Publication status | Published - May 2008 |
Abstract
Different approaches for the characterisation of relevant parameters of the low-voltage mains network, used for high-speed data transmission (BPL, broadband over power line) are described. Part 1 of the paper depicts the disturbance scenario of these BPL devices and the motivation will be given for the development of a new measurement procedure in CISPR for the estimation of the high-frequency characteristics of AC mains network. The improvements of the measurement method is not restricted to BPL applications, but can also be applied to other wire-based telecommunication systems. Part 2 of the paper shows the definitions and comparisons of different symmetry factors. The transfer of the results on the compliance test for BPL devices will be shown.
ASJC Scopus subject areas
- Physics and Astronomy(all)
- Atomic and Molecular Physics, and Optics
- Engineering(all)
- Electrical and Electronic Engineering
Cite this
- Standard
- Harvard
- Apa
- Vancouver
- BibTeX
- RIS
In: IET Science, Measurement and Technology, Vol. 2, No. 3, 05.2008, p. 146-153.
Research output: Contribution to journal › Article › Research › peer review
}
TY - JOUR
T1 - Electromagnetic compatibility analysis of unstructured mains networks for high-speed data transmission
T2 - Part 1
AU - Battermann, S.
AU - Garbe, H.
AU - Silva, F.
AU - Pous, M.
AU - Beauvois, V.
AU - Vantomme, K.
AU - Catrysse, J.
AU - Newbury, J.
AU - Degardin, V.
AU - Liénard, M.
AU - Degauque, P.
AU - Flintoft, I. D.
AU - Papatsoris, A. D.
AU - Welsh, D. W.
AU - Marvin, A. C.
PY - 2008/5
Y1 - 2008/5
N2 - Different approaches for the characterisation of relevant parameters of the low-voltage mains network, used for high-speed data transmission (BPL, broadband over power line) are described. Part 1 of the paper depicts the disturbance scenario of these BPL devices and the motivation will be given for the development of a new measurement procedure in CISPR for the estimation of the high-frequency characteristics of AC mains network. The improvements of the measurement method is not restricted to BPL applications, but can also be applied to other wire-based telecommunication systems. Part 2 of the paper shows the definitions and comparisons of different symmetry factors. The transfer of the results on the compliance test for BPL devices will be shown.
AB - Different approaches for the characterisation of relevant parameters of the low-voltage mains network, used for high-speed data transmission (BPL, broadband over power line) are described. Part 1 of the paper depicts the disturbance scenario of these BPL devices and the motivation will be given for the development of a new measurement procedure in CISPR for the estimation of the high-frequency characteristics of AC mains network. The improvements of the measurement method is not restricted to BPL applications, but can also be applied to other wire-based telecommunication systems. Part 2 of the paper shows the definitions and comparisons of different symmetry factors. The transfer of the results on the compliance test for BPL devices will be shown.
UR - http://www.scopus.com/inward/record.url?scp=40749135739&partnerID=8YFLogxK
U2 - 10.1049/iet-smt:20070055
DO - 10.1049/iet-smt:20070055
M3 - Article
AN - SCOPUS:40749135739
VL - 2
SP - 146
EP - 153
JO - IET Science, Measurement and Technology
JF - IET Science, Measurement and Technology
SN - 1751-8822
IS - 3
ER -