Effects of refractive index mismatch on SRS and CARS microscopy

Research output: Contribution to journalArticleResearchpeer review

Authors

External Research Organisations

  • University of Ottawa
View graph of relations

Details

Original languageEnglish
Pages (from-to)25752-25766
Number of pages15
JournalOptics express
Volume24
Issue number22
Publication statusPublished - Oct 2016
Externally publishedYes

Abstract

An inhomogeneous linear refractive index profile, such as that occurring in biological tissues, is shown to significantly alter stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) microscopy images. Our finite-difference time-domain simulations show that near-field enhancement and microlensing can lead to an increase of an object's perceived molecular density by a factor of nine and changes in its perceived position by 0.4 μm up to 1.0 μm. Thus the assumption that SRS scales linearly and CARS quadratically with density does not always hold. Furthermore, the inhomogeneous linear index can cause false CARS and AM-SRS signals, even for a homogeneous nonlinear susceptibility.

ASJC Scopus subject areas

Cite this

Effects of refractive index mismatch on SRS and CARS microscopy. / Van Der Kolk, Jarno; Lesina, Antonino Calà; Ramunno, Lora.
In: Optics express, Vol. 24, No. 22, 10.2016, p. 25752-25766.

Research output: Contribution to journalArticleResearchpeer review

Van Der Kolk J, Lesina AC, Ramunno L. Effects of refractive index mismatch on SRS and CARS microscopy. Optics express. 2016 Oct;24(22):25752-25766. doi: 10.1364/OE.24.025752
Van Der Kolk, Jarno ; Lesina, Antonino Calà ; Ramunno, Lora. / Effects of refractive index mismatch on SRS and CARS microscopy. In: Optics express. 2016 ; Vol. 24, No. 22. pp. 25752-25766.
Download
@article{f340769ba78b472eb68e604008b8aa28,
title = "Effects of refractive index mismatch on SRS and CARS microscopy",
abstract = "An inhomogeneous linear refractive index profile, such as that occurring in biological tissues, is shown to significantly alter stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) microscopy images. Our finite-difference time-domain simulations show that near-field enhancement and microlensing can lead to an increase of an object's perceived molecular density by a factor of nine and changes in its perceived position by 0.4 μm up to 1.0 μm. Thus the assumption that SRS scales linearly and CARS quadratically with density does not always hold. Furthermore, the inhomogeneous linear index can cause false CARS and AM-SRS signals, even for a homogeneous nonlinear susceptibility.",
author = "{Van Der Kolk}, Jarno and Lesina, {Antonino Cal{\`a}} and Lora Ramunno",
note = "Funding information: Natural Sciences and Engineering Research Council of Canada (NSERC); Canada Research Chairs (CRC); Southern Ontario Smart Computing Innovation Platform (SOSCIP); the Canadian Foundation for Innovation (CFI); Ministry of Research and Innovation Ontario. We would like to thank Sharcnet for the computational resources that made this article possible (NRAP1007/NRAP1352, up to 256 cores per simulation on orca).",
year = "2016",
month = oct,
doi = "10.1364/OE.24.025752",
language = "English",
volume = "24",
pages = "25752--25766",
journal = "Optics express",
issn = "1094-4087",
publisher = "OSA - The Optical Society",
number = "22",

}

Download

TY - JOUR

T1 - Effects of refractive index mismatch on SRS and CARS microscopy

AU - Van Der Kolk, Jarno

AU - Lesina, Antonino Calà

AU - Ramunno, Lora

N1 - Funding information: Natural Sciences and Engineering Research Council of Canada (NSERC); Canada Research Chairs (CRC); Southern Ontario Smart Computing Innovation Platform (SOSCIP); the Canadian Foundation for Innovation (CFI); Ministry of Research and Innovation Ontario. We would like to thank Sharcnet for the computational resources that made this article possible (NRAP1007/NRAP1352, up to 256 cores per simulation on orca).

PY - 2016/10

Y1 - 2016/10

N2 - An inhomogeneous linear refractive index profile, such as that occurring in biological tissues, is shown to significantly alter stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) microscopy images. Our finite-difference time-domain simulations show that near-field enhancement and microlensing can lead to an increase of an object's perceived molecular density by a factor of nine and changes in its perceived position by 0.4 μm up to 1.0 μm. Thus the assumption that SRS scales linearly and CARS quadratically with density does not always hold. Furthermore, the inhomogeneous linear index can cause false CARS and AM-SRS signals, even for a homogeneous nonlinear susceptibility.

AB - An inhomogeneous linear refractive index profile, such as that occurring in biological tissues, is shown to significantly alter stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) microscopy images. Our finite-difference time-domain simulations show that near-field enhancement and microlensing can lead to an increase of an object's perceived molecular density by a factor of nine and changes in its perceived position by 0.4 μm up to 1.0 μm. Thus the assumption that SRS scales linearly and CARS quadratically with density does not always hold. Furthermore, the inhomogeneous linear index can cause false CARS and AM-SRS signals, even for a homogeneous nonlinear susceptibility.

UR - http://www.scopus.com/inward/record.url?scp=84995899634&partnerID=8YFLogxK

U2 - 10.1364/OE.24.025752

DO - 10.1364/OE.24.025752

M3 - Article

AN - SCOPUS:84995899634

VL - 24

SP - 25752

EP - 25766

JO - Optics express

JF - Optics express

SN - 1094-4087

IS - 22

ER -

By the same author(s)