Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

  • Sahand Seifi
  • Peter Werle
  • Hossein Mohseni
  • Amir Abbas Shayegani Akmal

External Research Organisations

  • University of Tehran
View graph of relations

Details

Original languageEnglish
Title of host publicationProceedings of the 21st International Symposium on High Voltage Engineering
Subtitle of host publicationISH 2019
EditorsBálint Németh
Place of PublicationCham
Pages894-905
Number of pages12
Volume2
ISBN (electronic)978-3-030-31680-8
Publication statusPublished - 31 Oct 2019
Event21st International Symposium on High Voltage Engineering, ISH 2019 - Budapest, Hungary
Duration: 26 Aug 201930 Aug 2019

Publication series

NameLecture Notes in Electrical Engineering
PublisherSpringer Nature Switzerland
Volume599
ISSN (Print)1876-1100
ISSN (electronic)1876-1119

Abstract

Partial discharge (PD) measurement as a common method for assessing the insulation system of power transformers could be used to detect a fault in the insulation system in early stages. In general, finding the location of the fault in the insulation system is not straightforward even after removing the active part due to the complex structure of power transformers. Therefore, a precise PD localization can also substantially reduces the time and cost of troubleshooting. Electrical PD measurement is one of the methods for localization of PDs, which already is extensively applied for detecting PD signals. It also provides information regarding PD pattern and the signal shape, which are very valuable to evaluate the insulation system condition. In this method, two measured PD signals at two ends of the winding are employed for localization. The division of measured PD signals in the frequency domain by transfer functions of each point along the winding results in a pair of calculated signals. The point along the winding at that its pair of calculated signals is more similar to each other is the location of the original PD. In this contribution, some PDs are injected in different points along the winding of a distribution transformer using a PD calibrator. Thereupon, they are measured at the two winding ends and also in injection points. In the first step, the effect of measurement bandwidth on the shape of the measured PD pulses is investigated. Then, the effect of these bandwidths on PD localization is scrutinized.

Keywords

    Frequency domain analysis, Partial discharge localization, Power transformer

ASJC Scopus subject areas

Cite this

Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers. / Seifi, Sahand; Werle, Peter; Mohseni, Hossein et al.
Proceedings of the 21st International Symposium on High Voltage Engineering: ISH 2019. ed. / Bálint Németh. Vol. 2 Cham, 2019. p. 894-905 (Lecture Notes in Electrical Engineering; Vol. 599).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Seifi, S, Werle, P, Mohseni, H & Shayegani Akmal, AA 2019, Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers. in B Németh (ed.), Proceedings of the 21st International Symposium on High Voltage Engineering: ISH 2019. vol. 2, Lecture Notes in Electrical Engineering, vol. 599, Cham, pp. 894-905, 21st International Symposium on High Voltage Engineering, ISH 2019, Budapest, Hungary, 26 Aug 2019. https://doi.org/10.1007/978-3-030-31680-8_87
Seifi, S., Werle, P., Mohseni, H., & Shayegani Akmal, A. A. (2019). Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers. In B. Németh (Ed.), Proceedings of the 21st International Symposium on High Voltage Engineering: ISH 2019 (Vol. 2, pp. 894-905). (Lecture Notes in Electrical Engineering; Vol. 599).. https://doi.org/10.1007/978-3-030-31680-8_87
Seifi S, Werle P, Mohseni H, Shayegani Akmal AA. Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers. In Németh B, editor, Proceedings of the 21st International Symposium on High Voltage Engineering: ISH 2019. Vol. 2. Cham. 2019. p. 894-905. (Lecture Notes in Electrical Engineering). doi: 10.1007/978-3-030-31680-8_87
Seifi, Sahand ; Werle, Peter ; Mohseni, Hossein et al. / Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers. Proceedings of the 21st International Symposium on High Voltage Engineering: ISH 2019. editor / Bálint Németh. Vol. 2 Cham, 2019. pp. 894-905 (Lecture Notes in Electrical Engineering).
Download
@inproceedings{a67dd679f0e04bfe96595e81c01a337f,
title = "Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers",
abstract = "Partial discharge (PD) measurement as a common method for assessing the insulation system of power transformers could be used to detect a fault in the insulation system in early stages. In general, finding the location of the fault in the insulation system is not straightforward even after removing the active part due to the complex structure of power transformers. Therefore, a precise PD localization can also substantially reduces the time and cost of troubleshooting. Electrical PD measurement is one of the methods for localization of PDs, which already is extensively applied for detecting PD signals. It also provides information regarding PD pattern and the signal shape, which are very valuable to evaluate the insulation system condition. In this method, two measured PD signals at two ends of the winding are employed for localization. The division of measured PD signals in the frequency domain by transfer functions of each point along the winding results in a pair of calculated signals. The point along the winding at that its pair of calculated signals is more similar to each other is the location of the original PD. In this contribution, some PDs are injected in different points along the winding of a distribution transformer using a PD calibrator. Thereupon, they are measured at the two winding ends and also in injection points. In the first step, the effect of measurement bandwidth on the shape of the measured PD pulses is investigated. Then, the effect of these bandwidths on PD localization is scrutinized.",
keywords = "Frequency domain analysis, Partial discharge localization, Power transformer",
author = "Sahand Seifi and Peter Werle and Hossein Mohseni and {Shayegani Akmal}, {Amir Abbas}",
year = "2019",
month = oct,
day = "31",
doi = "10.1007/978-3-030-31680-8_87",
language = "English",
isbn = "978-3-030-31679-2",
volume = "2",
series = "Lecture Notes in Electrical Engineering",
publisher = "Springer Nature Switzerland",
pages = "894--905",
editor = "B{\'a}lint N{\'e}meth",
booktitle = "Proceedings of the 21st International Symposium on High Voltage Engineering",
note = "21st International Symposium on High Voltage Engineering, ISH 2019 ; Conference date: 26-08-2019 Through 30-08-2019",

}

Download

TY - GEN

T1 - Effect of Measurement Bandwidth on Partial Discharge Localization Accuracy in Power Transformers

AU - Seifi, Sahand

AU - Werle, Peter

AU - Mohseni, Hossein

AU - Shayegani Akmal, Amir Abbas

PY - 2019/10/31

Y1 - 2019/10/31

N2 - Partial discharge (PD) measurement as a common method for assessing the insulation system of power transformers could be used to detect a fault in the insulation system in early stages. In general, finding the location of the fault in the insulation system is not straightforward even after removing the active part due to the complex structure of power transformers. Therefore, a precise PD localization can also substantially reduces the time and cost of troubleshooting. Electrical PD measurement is one of the methods for localization of PDs, which already is extensively applied for detecting PD signals. It also provides information regarding PD pattern and the signal shape, which are very valuable to evaluate the insulation system condition. In this method, two measured PD signals at two ends of the winding are employed for localization. The division of measured PD signals in the frequency domain by transfer functions of each point along the winding results in a pair of calculated signals. The point along the winding at that its pair of calculated signals is more similar to each other is the location of the original PD. In this contribution, some PDs are injected in different points along the winding of a distribution transformer using a PD calibrator. Thereupon, they are measured at the two winding ends and also in injection points. In the first step, the effect of measurement bandwidth on the shape of the measured PD pulses is investigated. Then, the effect of these bandwidths on PD localization is scrutinized.

AB - Partial discharge (PD) measurement as a common method for assessing the insulation system of power transformers could be used to detect a fault in the insulation system in early stages. In general, finding the location of the fault in the insulation system is not straightforward even after removing the active part due to the complex structure of power transformers. Therefore, a precise PD localization can also substantially reduces the time and cost of troubleshooting. Electrical PD measurement is one of the methods for localization of PDs, which already is extensively applied for detecting PD signals. It also provides information regarding PD pattern and the signal shape, which are very valuable to evaluate the insulation system condition. In this method, two measured PD signals at two ends of the winding are employed for localization. The division of measured PD signals in the frequency domain by transfer functions of each point along the winding results in a pair of calculated signals. The point along the winding at that its pair of calculated signals is more similar to each other is the location of the original PD. In this contribution, some PDs are injected in different points along the winding of a distribution transformer using a PD calibrator. Thereupon, they are measured at the two winding ends and also in injection points. In the first step, the effect of measurement bandwidth on the shape of the measured PD pulses is investigated. Then, the effect of these bandwidths on PD localization is scrutinized.

KW - Frequency domain analysis

KW - Partial discharge localization

KW - Power transformer

UR - http://www.scopus.com/inward/record.url?scp=85085055785&partnerID=8YFLogxK

U2 - 10.1007/978-3-030-31680-8_87

DO - 10.1007/978-3-030-31680-8_87

M3 - Conference contribution

SN - 978-3-030-31679-2

SN - 978-3-030-31682-2

VL - 2

T3 - Lecture Notes in Electrical Engineering

SP - 894

EP - 905

BT - Proceedings of the 21st International Symposium on High Voltage Engineering

A2 - Németh, Bálint

CY - Cham

T2 - 21st International Symposium on High Voltage Engineering, ISH 2019

Y2 - 26 August 2019 through 30 August 2019

ER -

By the same author(s)