Direct measurement of residual gas effect on the sensitivity in TAMA300

Research output: Contribution to journalArticleResearchpeer review

Authors

  • R. Takahashi
  • Y. Saito
  • M. Fukushima
  • M. Ando
  • K. Arai
  • D. Tatsumi
  • G. Heinzel
  • S. Kawamura
  • T. Yamazaki
  • S. Moriwaki

Research Organisations

External Research Organisations

  • National Astronomical Observatory of Japan (NAOJ)
  • High Energy Accelerator Research Organization (KEK)
  • University of Tokyo
View graph of relations

Details

Original languageEnglish
Pages (from-to)1237-1241
Number of pages5
JournalJournal of Vacuum Science and Technology A: Vacuum, Surfaces and Films
Volume20
Issue number4
Publication statusPublished - 27 Jun 2002

Abstract

The residual-gas effect on the sensitivity in TAMA300 was measured directly. It was found that a Xe-gas pressure of 0.03 Pa induces an increase in the displacement noise of 3X10-18m/√Hz. This noise level was found to be consistent with a calculated optical path fluctuation due to residual gas within a factor of 2.

ASJC Scopus subject areas

Cite this

Direct measurement of residual gas effect on the sensitivity in TAMA300. / Takahashi, R.; Saito, Y.; Fukushima, M. et al.
In: Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films, Vol. 20, No. 4, 27.06.2002, p. 1237-1241.

Research output: Contribution to journalArticleResearchpeer review

Takahashi, R, Saito, Y, Fukushima, M, Ando, M, Arai, K, Tatsumi, D, Heinzel, G, Kawamura, S, Yamazaki, T & Moriwaki, S 2002, 'Direct measurement of residual gas effect on the sensitivity in TAMA300', Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films, vol. 20, no. 4, pp. 1237-1241. https://doi.org/10.1116/1.1479360
Takahashi, R., Saito, Y., Fukushima, M., Ando, M., Arai, K., Tatsumi, D., Heinzel, G., Kawamura, S., Yamazaki, T., & Moriwaki, S. (2002). Direct measurement of residual gas effect on the sensitivity in TAMA300. Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films, 20(4), 1237-1241. https://doi.org/10.1116/1.1479360
Takahashi R, Saito Y, Fukushima M, Ando M, Arai K, Tatsumi D et al. Direct measurement of residual gas effect on the sensitivity in TAMA300. Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films. 2002 Jun 27;20(4):1237-1241. doi: 10.1116/1.1479360
Takahashi, R. ; Saito, Y. ; Fukushima, M. et al. / Direct measurement of residual gas effect on the sensitivity in TAMA300. In: Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films. 2002 ; Vol. 20, No. 4. pp. 1237-1241.
Download
@article{ec7a8fcd94294867b113cfc15afa6ce2,
title = "Direct measurement of residual gas effect on the sensitivity in TAMA300",
abstract = "The residual-gas effect on the sensitivity in TAMA300 was measured directly. It was found that a Xe-gas pressure of 0.03 Pa induces an increase in the displacement noise of 3X10-18m/√Hz. This noise level was found to be consistent with a calculated optical path fluctuation due to residual gas within a factor of 2.",
author = "R. Takahashi and Y. Saito and M. Fukushima and M. Ando and K. Arai and D. Tatsumi and G. Heinzel and S. Kawamura and T. Yamazaki and S. Moriwaki",
year = "2002",
month = jun,
day = "27",
doi = "10.1116/1.1479360",
language = "English",
volume = "20",
pages = "1237--1241",
journal = "Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films",
issn = "0734-2101",
publisher = "AVS Science and Technology Society",
number = "4",

}

Download

TY - JOUR

T1 - Direct measurement of residual gas effect on the sensitivity in TAMA300

AU - Takahashi, R.

AU - Saito, Y.

AU - Fukushima, M.

AU - Ando, M.

AU - Arai, K.

AU - Tatsumi, D.

AU - Heinzel, G.

AU - Kawamura, S.

AU - Yamazaki, T.

AU - Moriwaki, S.

PY - 2002/6/27

Y1 - 2002/6/27

N2 - The residual-gas effect on the sensitivity in TAMA300 was measured directly. It was found that a Xe-gas pressure of 0.03 Pa induces an increase in the displacement noise of 3X10-18m/√Hz. This noise level was found to be consistent with a calculated optical path fluctuation due to residual gas within a factor of 2.

AB - The residual-gas effect on the sensitivity in TAMA300 was measured directly. It was found that a Xe-gas pressure of 0.03 Pa induces an increase in the displacement noise of 3X10-18m/√Hz. This noise level was found to be consistent with a calculated optical path fluctuation due to residual gas within a factor of 2.

UR - http://www.scopus.com/inward/record.url?scp=0036648855&partnerID=8YFLogxK

U2 - 10.1116/1.1479360

DO - 10.1116/1.1479360

M3 - Article

AN - SCOPUS:0036648855

VL - 20

SP - 1237

EP - 1241

JO - Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films

JF - Journal of Vacuum Science and Technology A: Vacuum, Surfaces and Films

SN - 0734-2101

IS - 4

ER -