Development of a linear optical coherence tomography low-cost system for ophthalmic applications

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

  • Niklas Bauer
  • Damian Mendroch
  • David Harings
  • Jan Matrisch
  • Uwe Oberheide
  • Alexander Heisterkamp

Research Organisations

External Research Organisations

  • TH Köln - University of Applied Sciences
View graph of relations

Details

Original languageEnglish
Title of host publicationBiomedical Spectroscopy, Microscopy, and Imaging III
EditorsJurgen Popp, Csilla Gergely
PublisherSPIE
ISBN (electronic)9781510673281
Publication statusPublished - 2024
EventSPIE Photonics Europe 2024: Advances in Ultrafast Condensed Phase Physics IV - Strasbourg, France
Duration: 7 Apr 202411 Apr 2024

Publication series

NameProceedings of SPIE - The International Society for Optical Engineering
Volume13006
ISSN (Print)0277-786X
ISSN (electronic)1996-756X

Abstract

This publication introduces a prototype of a fiber-based linear optical coherence tomography system (LOCT) that can be used for economical retinal screening in ophthalmology. The system uses standard off-the-shelf components to reduce production costs, complexity, and adjustment efforts while providing high-quality imaging of artificial retinal structures. We present the results of A- and B-scans of technical samples and an artificial eye model that was conducted to assess the system’s performance regarding axial resolution, imaging depth, and dispersion compensation. The study’s findings suggest that LOCT is a cost-effective solution for ophthalmology and shows great potential for monitoring the progression of retina-related diseases such as glaucoma or age-related macular degeneration.

Keywords

    LOCT, Low Cost OCT, OCT, Retinal Imaging

ASJC Scopus subject areas

Cite this

Development of a linear optical coherence tomography low-cost system for ophthalmic applications. / Bauer, Niklas; Mendroch, Damian; Harings, David et al.
Biomedical Spectroscopy, Microscopy, and Imaging III. ed. / Jurgen Popp; Csilla Gergely. SPIE, 2024. 130061B (Proceedings of SPIE - The International Society for Optical Engineering; Vol. 13006).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Bauer, N, Mendroch, D, Harings, D, Matrisch, J, Oberheide, U & Heisterkamp, A 2024, Development of a linear optical coherence tomography low-cost system for ophthalmic applications. in J Popp & C Gergely (eds), Biomedical Spectroscopy, Microscopy, and Imaging III., 130061B, Proceedings of SPIE - The International Society for Optical Engineering, vol. 13006, SPIE, SPIE Photonics Europe 2024, Strasbourg, France, 7 Apr 2024. https://doi.org/10.1117/12.3016988
Bauer, N., Mendroch, D., Harings, D., Matrisch, J., Oberheide, U., & Heisterkamp, A. (2024). Development of a linear optical coherence tomography low-cost system for ophthalmic applications. In J. Popp, & C. Gergely (Eds.), Biomedical Spectroscopy, Microscopy, and Imaging III Article 130061B (Proceedings of SPIE - The International Society for Optical Engineering; Vol. 13006). SPIE. https://doi.org/10.1117/12.3016988
Bauer N, Mendroch D, Harings D, Matrisch J, Oberheide U, Heisterkamp A. Development of a linear optical coherence tomography low-cost system for ophthalmic applications. In Popp J, Gergely C, editors, Biomedical Spectroscopy, Microscopy, and Imaging III. SPIE. 2024. 130061B. (Proceedings of SPIE - The International Society for Optical Engineering). Epub 2024 Jun 20. doi: 10.1117/12.3016988
Bauer, Niklas ; Mendroch, Damian ; Harings, David et al. / Development of a linear optical coherence tomography low-cost system for ophthalmic applications. Biomedical Spectroscopy, Microscopy, and Imaging III. editor / Jurgen Popp ; Csilla Gergely. SPIE, 2024. (Proceedings of SPIE - The International Society for Optical Engineering).
Download
@inproceedings{c8e9bf68cb324550a781c708015657ff,
title = "Development of a linear optical coherence tomography low-cost system for ophthalmic applications",
abstract = "This publication introduces a prototype of a fiber-based linear optical coherence tomography system (LOCT) that can be used for economical retinal screening in ophthalmology. The system uses standard off-the-shelf components to reduce production costs, complexity, and adjustment efforts while providing high-quality imaging of artificial retinal structures. We present the results of A- and B-scans of technical samples and an artificial eye model that was conducted to assess the system{\textquoteright}s performance regarding axial resolution, imaging depth, and dispersion compensation. The study{\textquoteright}s findings suggest that LOCT is a cost-effective solution for ophthalmology and shows great potential for monitoring the progression of retina-related diseases such as glaucoma or age-related macular degeneration.",
keywords = "LOCT, Low Cost OCT, OCT, Retinal Imaging",
author = "Niklas Bauer and Damian Mendroch and David Harings and Jan Matrisch and Uwe Oberheide and Alexander Heisterkamp",
note = "Publisher Copyright: {\textcopyright} 2024 SPIE.; SPIE Photonics Europe 2024 : Advances in Ultrafast Condensed Phase Physics IV ; Conference date: 07-04-2024 Through 11-04-2024",
year = "2024",
doi = "10.1117/12.3016988",
language = "English",
series = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "SPIE",
editor = "Jurgen Popp and Csilla Gergely",
booktitle = "Biomedical Spectroscopy, Microscopy, and Imaging III",
address = "United States",

}

Download

TY - GEN

T1 - Development of a linear optical coherence tomography low-cost system for ophthalmic applications

AU - Bauer, Niklas

AU - Mendroch, Damian

AU - Harings, David

AU - Matrisch, Jan

AU - Oberheide, Uwe

AU - Heisterkamp, Alexander

N1 - Publisher Copyright: © 2024 SPIE.

PY - 2024

Y1 - 2024

N2 - This publication introduces a prototype of a fiber-based linear optical coherence tomography system (LOCT) that can be used for economical retinal screening in ophthalmology. The system uses standard off-the-shelf components to reduce production costs, complexity, and adjustment efforts while providing high-quality imaging of artificial retinal structures. We present the results of A- and B-scans of technical samples and an artificial eye model that was conducted to assess the system’s performance regarding axial resolution, imaging depth, and dispersion compensation. The study’s findings suggest that LOCT is a cost-effective solution for ophthalmology and shows great potential for monitoring the progression of retina-related diseases such as glaucoma or age-related macular degeneration.

AB - This publication introduces a prototype of a fiber-based linear optical coherence tomography system (LOCT) that can be used for economical retinal screening in ophthalmology. The system uses standard off-the-shelf components to reduce production costs, complexity, and adjustment efforts while providing high-quality imaging of artificial retinal structures. We present the results of A- and B-scans of technical samples and an artificial eye model that was conducted to assess the system’s performance regarding axial resolution, imaging depth, and dispersion compensation. The study’s findings suggest that LOCT is a cost-effective solution for ophthalmology and shows great potential for monitoring the progression of retina-related diseases such as glaucoma or age-related macular degeneration.

KW - LOCT

KW - Low Cost OCT

KW - OCT

KW - Retinal Imaging

UR - http://www.scopus.com/inward/record.url?scp=85198912839&partnerID=8YFLogxK

U2 - 10.1117/12.3016988

DO - 10.1117/12.3016988

M3 - Conference contribution

AN - SCOPUS:85198912839

T3 - Proceedings of SPIE - The International Society for Optical Engineering

BT - Biomedical Spectroscopy, Microscopy, and Imaging III

A2 - Popp, Jurgen

A2 - Gergely, Csilla

PB - SPIE

T2 - SPIE Photonics Europe 2024

Y2 - 7 April 2024 through 11 April 2024

ER -