Abstract

Fluorescence spectroscopy is a highly sensitive and non-invasive technique for the identification of characteristic process states and for the online monitoring of substrate and product concentrations. Nevertheless, fluorescence sensors are mainly used in academic studies and are not well implemented for monitoring of industrial production processes. In this work, we present a newly developed robust online fluorescence sensor that facilitates the analysis of fluorescence measurements. The set-up of the sensor was miniaturised and realised without any moveable part to be robust enough for application in technical environments. It was constructed to measure only the three most important biologic fluorophores (tryptophan, NADH and FAD/FMN), resulting in a significant data reduction compared to conventional a 2-D fluorescence spectrometer. The sensor performance was evaluated by calibration curves and selectivity tests. The measuring ranges were determined as 0.5-50 μmolL-1 for NADH and 0.0025-7.5 μmolL-1 for BSA and riboflavin. Online monitoring of batch cultivations of wild-type Escherichia coli K1 in a 10 L bioreactor scale were performed. The data sets were analysed using principal component analysis and partial least square regression. The recorded fluorescence data were successfully used to predict the biomass of an independent cultivation (RMSEP 4.6 %).

ASJC Scopus subject areas

Cite this

Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses. / König, Jan C.; Steinwedel, Tobias; Solle, Dörte et al.
In: Journal of Sensors and Sensor Systems, Vol. 7, No. 2, 08.08.2018, p. 461-467.

Research output: Contribution to journalArticleResearchpeer review

König, JC, Steinwedel, T, Solle, D, Lindner, P, De Vries, I, Hentrop, T, Findeis, M, John, GT, Scheper, T & Beutel, S 2018, 'Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses', Journal of Sensors and Sensor Systems, vol. 7, no. 2, pp. 461-467. https://doi.org/10.5194/jsss-7-461-2018, https://doi.org/10.15488/3781
König, J. C., Steinwedel, T., Solle, D., Lindner, P., De Vries, I., Hentrop, T., Findeis, M., John, G. T., Scheper, T., & Beutel, S. (2018). Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses. Journal of Sensors and Sensor Systems, 7(2), 461-467. https://doi.org/10.5194/jsss-7-461-2018, https://doi.org/10.15488/3781
König JC, Steinwedel T, Solle D, Lindner P, De Vries I, Hentrop T et al. Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses. Journal of Sensors and Sensor Systems. 2018 Aug 8;7(2):461-467. doi: 10.5194/jsss-7-461-2018, 10.15488/3781
König, Jan C. ; Steinwedel, Tobias ; Solle, Dörte et al. / Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses. In: Journal of Sensors and Sensor Systems. 2018 ; Vol. 7, No. 2. pp. 461-467.
Download
@article{2b7453aa3d9945a79ace91a09a25ea8a,
title = "Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses",
abstract = "Fluorescence spectroscopy is a highly sensitive and non-invasive technique for the identification of characteristic process states and for the online monitoring of substrate and product concentrations. Nevertheless, fluorescence sensors are mainly used in academic studies and are not well implemented for monitoring of industrial production processes. In this work, we present a newly developed robust online fluorescence sensor that facilitates the analysis of fluorescence measurements. The set-up of the sensor was miniaturised and realised without any moveable part to be robust enough for application in technical environments. It was constructed to measure only the three most important biologic fluorophores (tryptophan, NADH and FAD/FMN), resulting in a significant data reduction compared to conventional a 2-D fluorescence spectrometer. The sensor performance was evaluated by calibration curves and selectivity tests. The measuring ranges were determined as 0.5-50 μmolL-1 for NADH and 0.0025-7.5 μmolL-1 for BSA and riboflavin. Online monitoring of batch cultivations of wild-type Escherichia coli K1 in a 10 L bioreactor scale were performed. The data sets were analysed using principal component analysis and partial least square regression. The recorded fluorescence data were successfully used to predict the biomass of an independent cultivation (RMSEP 4.6 %).",
author = "K{\"o}nig, {Jan C.} and Tobias Steinwedel and D{\"o}rte Solle and Patrick Lindner and {De Vries}, Ingo and Thorleif Hentrop and Michael Findeis and John, {Gernot T.} and Thomas Scheper and Sascha Beutel",
note = "Funding information:. We would like to thank all members of our research group for providing feedback and suggestions. This project was funded by the BMWi via AiF within the ZIM initiative.",
year = "2018",
month = aug,
day = "8",
doi = "10.5194/jsss-7-461-2018",
language = "English",
volume = "7",
pages = "461--467",
number = "2",

}

Download

TY - JOUR

T1 - Development and characterisation of a new fluorescence sensor for online monitoring of bioprocesses

AU - König, Jan C.

AU - Steinwedel, Tobias

AU - Solle, Dörte

AU - Lindner, Patrick

AU - De Vries, Ingo

AU - Hentrop, Thorleif

AU - Findeis, Michael

AU - John, Gernot T.

AU - Scheper, Thomas

AU - Beutel, Sascha

N1 - Funding information:. We would like to thank all members of our research group for providing feedback and suggestions. This project was funded by the BMWi via AiF within the ZIM initiative.

PY - 2018/8/8

Y1 - 2018/8/8

N2 - Fluorescence spectroscopy is a highly sensitive and non-invasive technique for the identification of characteristic process states and for the online monitoring of substrate and product concentrations. Nevertheless, fluorescence sensors are mainly used in academic studies and are not well implemented for monitoring of industrial production processes. In this work, we present a newly developed robust online fluorescence sensor that facilitates the analysis of fluorescence measurements. The set-up of the sensor was miniaturised and realised without any moveable part to be robust enough for application in technical environments. It was constructed to measure only the three most important biologic fluorophores (tryptophan, NADH and FAD/FMN), resulting in a significant data reduction compared to conventional a 2-D fluorescence spectrometer. The sensor performance was evaluated by calibration curves and selectivity tests. The measuring ranges were determined as 0.5-50 μmolL-1 for NADH and 0.0025-7.5 μmolL-1 for BSA and riboflavin. Online monitoring of batch cultivations of wild-type Escherichia coli K1 in a 10 L bioreactor scale were performed. The data sets were analysed using principal component analysis and partial least square regression. The recorded fluorescence data were successfully used to predict the biomass of an independent cultivation (RMSEP 4.6 %).

AB - Fluorescence spectroscopy is a highly sensitive and non-invasive technique for the identification of characteristic process states and for the online monitoring of substrate and product concentrations. Nevertheless, fluorescence sensors are mainly used in academic studies and are not well implemented for monitoring of industrial production processes. In this work, we present a newly developed robust online fluorescence sensor that facilitates the analysis of fluorescence measurements. The set-up of the sensor was miniaturised and realised without any moveable part to be robust enough for application in technical environments. It was constructed to measure only the three most important biologic fluorophores (tryptophan, NADH and FAD/FMN), resulting in a significant data reduction compared to conventional a 2-D fluorescence spectrometer. The sensor performance was evaluated by calibration curves and selectivity tests. The measuring ranges were determined as 0.5-50 μmolL-1 for NADH and 0.0025-7.5 μmolL-1 for BSA and riboflavin. Online monitoring of batch cultivations of wild-type Escherichia coli K1 in a 10 L bioreactor scale were performed. The data sets were analysed using principal component analysis and partial least square regression. The recorded fluorescence data were successfully used to predict the biomass of an independent cultivation (RMSEP 4.6 %).

UR - http://www.scopus.com/inward/record.url?scp=85051323310&partnerID=8YFLogxK

U2 - 10.5194/jsss-7-461-2018

DO - 10.5194/jsss-7-461-2018

M3 - Article

AN - SCOPUS:85051323310

VL - 7

SP - 461

EP - 467

JO - Journal of Sensors and Sensor Systems

JF - Journal of Sensors and Sensor Systems

SN - 2194-8771

IS - 2

ER -

By the same author(s)