Determination of transfer function of power transformer winding sections for partial discharge localization using design information

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

View graph of relations

Details

Original languageEnglish
Title of host publication2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages191-194
Number of pages4
ISBN (electronic)9781509046546
Publication statusPublished - 15 Dec 2016
Event2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016 - Toronto, Canada
Duration: 16 Oct 201619 Oct 2016

Publication series

NameAnnual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
Volume2016-December
ISSN (Print)0084-9162

Abstract

The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.

ASJC Scopus subject areas

Cite this

Determination of transfer function of power transformer winding sections for partial discharge localization using design information. / Rahimbakhsh, Mahdi; Werle, Peter; Gockenbach, Ernst.
2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016. Institute of Electrical and Electronics Engineers Inc., 2016. p. 191-194 7785498 (Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP; Vol. 2016-December).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Rahimbakhsh, M, Werle, P & Gockenbach, E 2016, Determination of transfer function of power transformer winding sections for partial discharge localization using design information. in 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016., 7785498, Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP, vol. 2016-December, Institute of Electrical and Electronics Engineers Inc., pp. 191-194, 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016, Toronto, Canada, 16 Oct 2016. https://doi.org/10.1109/CEIDP.2016.7785498
Rahimbakhsh, M., Werle, P., & Gockenbach, E. (2016). Determination of transfer function of power transformer winding sections for partial discharge localization using design information. In 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016 (pp. 191-194). Article 7785498 (Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP; Vol. 2016-December). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/CEIDP.2016.7785498
Rahimbakhsh M, Werle P, Gockenbach E. Determination of transfer function of power transformer winding sections for partial discharge localization using design information. In 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016. Institute of Electrical and Electronics Engineers Inc. 2016. p. 191-194. 7785498. (Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP). doi: 10.1109/CEIDP.2016.7785498
Rahimbakhsh, Mahdi ; Werle, Peter ; Gockenbach, Ernst. / Determination of transfer function of power transformer winding sections for partial discharge localization using design information. 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016. Institute of Electrical and Electronics Engineers Inc., 2016. pp. 191-194 (Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP).
Download
@inproceedings{3a6df3ac8ebd448f96891917928d2c65,
title = "Determination of transfer function of power transformer winding sections for partial discharge localization using design information",
abstract = "The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.",
author = "Mahdi Rahimbakhsh and Peter Werle and Ernst Gockenbach",
note = "Publisher Copyright: {\textcopyright} 2016 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.; 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016 ; Conference date: 16-10-2016 Through 19-10-2016",
year = "2016",
month = dec,
day = "15",
doi = "10.1109/CEIDP.2016.7785498",
language = "English",
series = "Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "191--194",
booktitle = "2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016",
address = "United States",

}

Download

TY - GEN

T1 - Determination of transfer function of power transformer winding sections for partial discharge localization using design information

AU - Rahimbakhsh, Mahdi

AU - Werle, Peter

AU - Gockenbach, Ernst

N1 - Publisher Copyright: © 2016 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.

PY - 2016/12/15

Y1 - 2016/12/15

N2 - The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.

AB - The paper focuses on simulating the transfer function of power transformer winding sections based on design information. The calculation method has been investigated and discussed. The simulation of windings through multi conductor transmission line method has been performed for an actual distribution transformer in the laboratory using the design information. With this information the transfer function of the transformer winding sections has been calculated. Additionally some measurements on the distribution transformer have been done in three test platforms with different measurement devices in order to compare the methods for evaluating the transfer function of this transformer. The simulated transfer function has been adapted by comparison between the simulation and measurement results. As a result of the comparison, a deviation factor could be defined and the most sensitive parameters of the simulation methods could be identified. The difference between simulation and measurement leads to knowledge about the required measurements on a transformer as basis for the simulation of the transfer function of the transformer winding sections.

UR - http://www.scopus.com/inward/record.url?scp=85009829433&partnerID=8YFLogxK

U2 - 10.1109/CEIDP.2016.7785498

DO - 10.1109/CEIDP.2016.7785498

M3 - Conference contribution

AN - SCOPUS:85009829433

T3 - Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP

SP - 191

EP - 194

BT - 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016

PB - Institute of Electrical and Electronics Engineers Inc.

T2 - 2016 IEEE Conference on Electrical Insulation and Dielectric Phenomena, CEIDP 2016

Y2 - 16 October 2016 through 19 October 2016

ER -