Crushing behavior of GFRP composite-reinforced PVC tubes: Experimental testing and numerical simulation

Research output: Contribution to journalArticleResearchpeer review

Authors

Research Organisations

External Research Organisations

  • Sudan University of Science and Technology (SUST)
  • Qatar University
View graph of relations

Details

Original languageEnglish
Article number110903
JournalComposites science and technology
Volume258
Early online date10 Oct 2024
Publication statusPublished - 10 Nov 2024

Abstract

This paper introduces glass fiber reinforced polymer (GFRP)-reinforced Polyvinyl Chloride (PVC) tubes, both corrugated and non-corrugated, designed as energy absorber devices. The PVC tubes were externally and internally reinforced with GFRP composite oriented at ±45 and subjected to quasi-static axial compression tests. Results indicated that all reinforced tubes exhibited significantly higher load-bearing capacity, energy absorption (EA) capability, and crushing force efficiency (CFE) compared to standard PVC tubes. Among the tested specimens, externally reinforced corrugated tubes demonstrated the highest specific energy absorption (SEA), surpassing other configurations by 17.5 kJ/kg when considering both pre- and post-crushing stages combined. However, these corrugated specimens showed instability during crushing, reflected in poor instantaneous crush force efficiency (iCFE) and the lowest iCFE among the composite tubes, with an average decrease of 43.59%. The corrugation notably increased the initial peak load, enhancing energy absorption in the pre-crushing stage without compromising the stability of crush force efficiency. Additionally, the combination of external and internal reinforcement significantly improved CFE and iCFE. Consequently, the PVC tubes combining corrugation with both external and internal reinforcement emerged as the best-performing configuration among all tested tubes. Furthermore, a 3D Finite Element (FE) model was developed using ABAQUS FE code with user-defined subroutines to simulate the crushing process. The constitutive models and numerical procedures employed are detailed. The FE model's predictions showed a satisfactory correlation with experimental results, providing valuable insights into the crushing mechanics and offering a predictive tool for future design optimizations.

Keywords

    Axial compression, Composites, Corrugation, Crashworthiness, Energy absorption, Finite element analysis (FEA)

ASJC Scopus subject areas

Cite this

Crushing behavior of GFRP composite-reinforced PVC tubes: Experimental testing and numerical simulation. / Yousif, Khaled; Dean, Aamir; Mahdi, Elsadig.
In: Composites science and technology, Vol. 258, 110903, 10.11.2024.

Research output: Contribution to journalArticleResearchpeer review

Yousif K, Dean A, Mahdi E. Crushing behavior of GFRP composite-reinforced PVC tubes: Experimental testing and numerical simulation. Composites science and technology. 2024 Nov 10;258:110903. Epub 2024 Oct 10. doi: 10.1016/j.compscitech.2024.110903
Download
@article{86a133986dba40d7a127a3af2ae517d7,
title = "Crushing behavior of GFRP composite-reinforced PVC tubes: Experimental testing and numerical simulation",
abstract = "This paper introduces glass fiber reinforced polymer (GFRP)-reinforced Polyvinyl Chloride (PVC) tubes, both corrugated and non-corrugated, designed as energy absorber devices. The PVC tubes were externally and internally reinforced with GFRP composite oriented at ±45∘ and subjected to quasi-static axial compression tests. Results indicated that all reinforced tubes exhibited significantly higher load-bearing capacity, energy absorption (EA) capability, and crushing force efficiency (CFE) compared to standard PVC tubes. Among the tested specimens, externally reinforced corrugated tubes demonstrated the highest specific energy absorption (SEA), surpassing other configurations by 17.5 kJ/kg when considering both pre- and post-crushing stages combined. However, these corrugated specimens showed instability during crushing, reflected in poor instantaneous crush force efficiency (iCFE) and the lowest iCFE among the composite tubes, with an average decrease of 43.59%. The corrugation notably increased the initial peak load, enhancing energy absorption in the pre-crushing stage without compromising the stability of crush force efficiency. Additionally, the combination of external and internal reinforcement significantly improved CFE and iCFE. Consequently, the PVC tubes combining corrugation with both external and internal reinforcement emerged as the best-performing configuration among all tested tubes. Furthermore, a 3D Finite Element (FE) model was developed using ABAQUS FE code with user-defined subroutines to simulate the crushing process. The constitutive models and numerical procedures employed are detailed. The FE model's predictions showed a satisfactory correlation with experimental results, providing valuable insights into the crushing mechanics and offering a predictive tool for future design optimizations.",
keywords = "Axial compression, Composites, Corrugation, Crashworthiness, Energy absorption, Finite element analysis (FEA)",
author = "Khaled Yousif and Aamir Dean and Elsadig Mahdi",
note = "Publisher Copyright: {\textcopyright} 2024 The Authors",
year = "2024",
month = nov,
day = "10",
doi = "10.1016/j.compscitech.2024.110903",
language = "English",
volume = "258",
journal = "Composites science and technology",
issn = "0266-3538",
publisher = "Elsevier BV",

}

Download

TY - JOUR

T1 - Crushing behavior of GFRP composite-reinforced PVC tubes

T2 - Experimental testing and numerical simulation

AU - Yousif, Khaled

AU - Dean, Aamir

AU - Mahdi, Elsadig

N1 - Publisher Copyright: © 2024 The Authors

PY - 2024/11/10

Y1 - 2024/11/10

N2 - This paper introduces glass fiber reinforced polymer (GFRP)-reinforced Polyvinyl Chloride (PVC) tubes, both corrugated and non-corrugated, designed as energy absorber devices. The PVC tubes were externally and internally reinforced with GFRP composite oriented at ±45∘ and subjected to quasi-static axial compression tests. Results indicated that all reinforced tubes exhibited significantly higher load-bearing capacity, energy absorption (EA) capability, and crushing force efficiency (CFE) compared to standard PVC tubes. Among the tested specimens, externally reinforced corrugated tubes demonstrated the highest specific energy absorption (SEA), surpassing other configurations by 17.5 kJ/kg when considering both pre- and post-crushing stages combined. However, these corrugated specimens showed instability during crushing, reflected in poor instantaneous crush force efficiency (iCFE) and the lowest iCFE among the composite tubes, with an average decrease of 43.59%. The corrugation notably increased the initial peak load, enhancing energy absorption in the pre-crushing stage without compromising the stability of crush force efficiency. Additionally, the combination of external and internal reinforcement significantly improved CFE and iCFE. Consequently, the PVC tubes combining corrugation with both external and internal reinforcement emerged as the best-performing configuration among all tested tubes. Furthermore, a 3D Finite Element (FE) model was developed using ABAQUS FE code with user-defined subroutines to simulate the crushing process. The constitutive models and numerical procedures employed are detailed. The FE model's predictions showed a satisfactory correlation with experimental results, providing valuable insights into the crushing mechanics and offering a predictive tool for future design optimizations.

AB - This paper introduces glass fiber reinforced polymer (GFRP)-reinforced Polyvinyl Chloride (PVC) tubes, both corrugated and non-corrugated, designed as energy absorber devices. The PVC tubes were externally and internally reinforced with GFRP composite oriented at ±45∘ and subjected to quasi-static axial compression tests. Results indicated that all reinforced tubes exhibited significantly higher load-bearing capacity, energy absorption (EA) capability, and crushing force efficiency (CFE) compared to standard PVC tubes. Among the tested specimens, externally reinforced corrugated tubes demonstrated the highest specific energy absorption (SEA), surpassing other configurations by 17.5 kJ/kg when considering both pre- and post-crushing stages combined. However, these corrugated specimens showed instability during crushing, reflected in poor instantaneous crush force efficiency (iCFE) and the lowest iCFE among the composite tubes, with an average decrease of 43.59%. The corrugation notably increased the initial peak load, enhancing energy absorption in the pre-crushing stage without compromising the stability of crush force efficiency. Additionally, the combination of external and internal reinforcement significantly improved CFE and iCFE. Consequently, the PVC tubes combining corrugation with both external and internal reinforcement emerged as the best-performing configuration among all tested tubes. Furthermore, a 3D Finite Element (FE) model was developed using ABAQUS FE code with user-defined subroutines to simulate the crushing process. The constitutive models and numerical procedures employed are detailed. The FE model's predictions showed a satisfactory correlation with experimental results, providing valuable insights into the crushing mechanics and offering a predictive tool for future design optimizations.

KW - Axial compression

KW - Composites

KW - Corrugation

KW - Crashworthiness

KW - Energy absorption

KW - Finite element analysis (FEA)

UR - http://www.scopus.com/inward/record.url?scp=85206853874&partnerID=8YFLogxK

U2 - 10.1016/j.compscitech.2024.110903

DO - 10.1016/j.compscitech.2024.110903

M3 - Article

AN - SCOPUS:85206853874

VL - 258

JO - Composites science and technology

JF - Composites science and technology

SN - 0266-3538

M1 - 110903

ER -

By the same author(s)