CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

Research Organisations

External Research Organisations

  • Ulmer Fundamental Symmetries Laboratory
  • Physikalisch-Technische Bundesanstalt PTB
View graph of relations

Details

Original languageEnglish
Title of host publicationProceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013
EditorsV. Alan Kostelecky
PublisherWorld Scientific Publishing Co. Pte Ltd
Pages41-44
Number of pages4
ISBN (print)9789814566421
Publication statusPublished - 1 Jan 2014
Event6th Meeting on CPT and Lorentz Symmetry, CPT 2013 - Bloomington, United States
Duration: 17 Jun 201321 Sept 2013

Abstract

Dehmelt and VanDyck’s famous 1987 measurement of the electron and positron g-factor is still the most precise g-factor comparison in the lepton sector, and a sensitive test of possible CPT violation. A complementary gfactor comparison between the proton and the antiproton is highly desirable to test CPT symmetry in the baryon sector. Current experiments, based on Dehmelt’s continuous Stern-Gerlach effect and the double Penning-trap technique, are making rapid progress. They are, however, extremely difficult to carry out because ground state cooling using cryogenic techniques is virtually impossible for heavy baryons, and because the continous Stern-Gerlach effect scales as μ/m, where m is the mass of the particle and μ its magnetic moment. Both difficulties will ultimately limit the accuracy. We discuss experimental prospects of realizing an alternative approach to a g-factor comparison with single (anti)protons, based on quantum logic techniques proposed by Heinzen and Wineland and by Wineland et al. The basic idea is to cool, control and measure single (anti)protons through interaction with a well-controlled atomicion.

ASJC Scopus subject areas

Cite this

CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout. / Niemann, M.; Paschke, A. G.; Dubielzig, T. et al.
Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013. ed. / V. Alan Kostelecky. World Scientific Publishing Co. Pte Ltd, 2014. p. 41-44.

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Niemann, M, Paschke, AG, Dubielzig, T, Ulmer, S & Ospelkaus, C 2014, CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout. in VA Kostelecky (ed.), Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013. World Scientific Publishing Co. Pte Ltd, pp. 41-44, 6th Meeting on CPT and Lorentz Symmetry, CPT 2013, Bloomington, United States, 17 Jun 2013. https://doi.org/10.1142/9789814566438_0011
Niemann, M., Paschke, A. G., Dubielzig, T., Ulmer, S., & Ospelkaus, C. (2014). CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout. In V. A. Kostelecky (Ed.), Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013 (pp. 41-44). World Scientific Publishing Co. Pte Ltd. https://doi.org/10.1142/9789814566438_0011
Niemann M, Paschke AG, Dubielzig T, Ulmer S, Ospelkaus C. CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout. In Kostelecky VA, editor, Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013. World Scientific Publishing Co. Pte Ltd. 2014. p. 41-44 doi: 10.1142/9789814566438_0011
Niemann, M. ; Paschke, A. G. ; Dubielzig, T. et al. / CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout. Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013. editor / V. Alan Kostelecky. World Scientific Publishing Co. Pte Ltd, 2014. pp. 41-44
Download
@inproceedings{fec0feba0eea4558a80e0c322466a7ab,
title = "CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout",
abstract = "Dehmelt and VanDyck{\textquoteright}s famous 1987 measurement of the electron and positron g-factor is still the most precise g-factor comparison in the lepton sector, and a sensitive test of possible CPT violation. A complementary gfactor comparison between the proton and the antiproton is highly desirable to test CPT symmetry in the baryon sector. Current experiments, based on Dehmelt{\textquoteright}s continuous Stern-Gerlach effect and the double Penning-trap technique, are making rapid progress. They are, however, extremely difficult to carry out because ground state cooling using cryogenic techniques is virtually impossible for heavy baryons, and because the continous Stern-Gerlach effect scales as μ/m, where m is the mass of the particle and μ its magnetic moment. Both difficulties will ultimately limit the accuracy. We discuss experimental prospects of realizing an alternative approach to a g-factor comparison with single (anti)protons, based on quantum logic techniques proposed by Heinzen and Wineland and by Wineland et al. The basic idea is to cool, control and measure single (anti)protons through interaction with a well-controlled atomicion.",
author = "M. Niemann and Paschke, {A. G.} and T. Dubielzig and S. Ulmer and C. Ospelkaus",
note = "Funding information: We acknowledge funding by QUEST, Gottfried Wilhelm LUH, PTB and RIKEN.; 6th Meeting on CPT and Lorentz Symmetry, CPT 2013 ; Conference date: 17-06-2013 Through 21-09-2013",
year = "2014",
month = jan,
day = "1",
doi = "10.1142/9789814566438_0011",
language = "English",
isbn = "9789814566421",
pages = "41--44",
editor = "Kostelecky, {V. Alan}",
booktitle = "Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013",
publisher = "World Scientific Publishing Co. Pte Ltd",
address = "Singapore",

}

Download

TY - GEN

T1 - CPT test with (anti)proton magnetic moments based on quantum logic cooling and readout

AU - Niemann, M.

AU - Paschke, A. G.

AU - Dubielzig, T.

AU - Ulmer, S.

AU - Ospelkaus, C.

N1 - Funding information: We acknowledge funding by QUEST, Gottfried Wilhelm LUH, PTB and RIKEN.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Dehmelt and VanDyck’s famous 1987 measurement of the electron and positron g-factor is still the most precise g-factor comparison in the lepton sector, and a sensitive test of possible CPT violation. A complementary gfactor comparison between the proton and the antiproton is highly desirable to test CPT symmetry in the baryon sector. Current experiments, based on Dehmelt’s continuous Stern-Gerlach effect and the double Penning-trap technique, are making rapid progress. They are, however, extremely difficult to carry out because ground state cooling using cryogenic techniques is virtually impossible for heavy baryons, and because the continous Stern-Gerlach effect scales as μ/m, where m is the mass of the particle and μ its magnetic moment. Both difficulties will ultimately limit the accuracy. We discuss experimental prospects of realizing an alternative approach to a g-factor comparison with single (anti)protons, based on quantum logic techniques proposed by Heinzen and Wineland and by Wineland et al. The basic idea is to cool, control and measure single (anti)protons through interaction with a well-controlled atomicion.

AB - Dehmelt and VanDyck’s famous 1987 measurement of the electron and positron g-factor is still the most precise g-factor comparison in the lepton sector, and a sensitive test of possible CPT violation. A complementary gfactor comparison between the proton and the antiproton is highly desirable to test CPT symmetry in the baryon sector. Current experiments, based on Dehmelt’s continuous Stern-Gerlach effect and the double Penning-trap technique, are making rapid progress. They are, however, extremely difficult to carry out because ground state cooling using cryogenic techniques is virtually impossible for heavy baryons, and because the continous Stern-Gerlach effect scales as μ/m, where m is the mass of the particle and μ its magnetic moment. Both difficulties will ultimately limit the accuracy. We discuss experimental prospects of realizing an alternative approach to a g-factor comparison with single (anti)protons, based on quantum logic techniques proposed by Heinzen and Wineland and by Wineland et al. The basic idea is to cool, control and measure single (anti)protons through interaction with a well-controlled atomicion.

UR - http://www.scopus.com/inward/record.url?scp=85012287012&partnerID=8YFLogxK

U2 - 10.1142/9789814566438_0011

DO - 10.1142/9789814566438_0011

M3 - Conference contribution

AN - SCOPUS:85012287012

SN - 9789814566421

SP - 41

EP - 44

BT - Proceedings of the 6th Meeting on CPT and Lorentz Symmetry, CPT 2013

A2 - Kostelecky, V. Alan

PB - World Scientific Publishing Co. Pte Ltd

T2 - 6th Meeting on CPT and Lorentz Symmetry, CPT 2013

Y2 - 17 June 2013 through 21 September 2013

ER -

By the same author(s)