Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

External Research Organisations

  • Drägerwerk AG & co. KG
View graph of relations

Details

Original languageEnglish
Title of host publicationSENSORS, 2007 IEEE
Pages79-82
Number of pages4
ISBN (electronic)9781424412624
Publication statusPublished - 17 Dec 2007
Externally publishedYes
Event6th IEEE Conference on SENSORS - Hyatt Regency Atlanta, Atlanta, United States
Duration: 28 Oct 200731 Oct 2007
Conference number: 6
http://ewh.ieee.org/conf/sensors2007/

Publication series

NameProceedings of IEEE Sensors
ISSN (Print)1930-0395
ISSN (electronic)2168-9229

Abstract

Ion mobility spectrometry (IMS) is a widely used method for detecting low ppb-level concentrations of hazardous compounds, such as chemical warfare agents, explosives and pollutants in air. Simple instrumentation combined with high sensitivity and high selectivity are major advantages of this technique. This paper presents both a novel concept of a miniaturized IMS that is capable of identifying hazardous compounds in air at low ppb-levels and a numerical model based on finite element analysis for fast system design. The model described here considers for the fist time all significant physical effects on the ion transport in an IMS, such as diffusion, coulomb repulsion, electric fields and gas flows. The simulations perfectly match the observations made with our experimental setup. This allowed rapid system optimization towards the highest performance possible under the given physical and economic constraints.

ASJC Scopus subject areas

Cite this

Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization. / Barth, S.; Baether, W.; Zimmermann, S.
SENSORS, 2007 IEEE. 2007. p. 79-82 (Proceedings of IEEE Sensors).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Barth, S, Baether, W & Zimmermann, S 2007, Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization. in SENSORS, 2007 IEEE. Proceedings of IEEE Sensors, pp. 79-82, 6th IEEE Conference on SENSORS, Atlanta, Georgia, United States, 28 Oct 2007. https://doi.org/10.1109/ICSENS.2007.4388340
Barth S, Baether W, Zimmermann S. Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization. In SENSORS, 2007 IEEE. 2007. p. 79-82. (Proceedings of IEEE Sensors). doi: 10.1109/ICSENS.2007.4388340
Barth, S. ; Baether, W. ; Zimmermann, S. / Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization. SENSORS, 2007 IEEE. 2007. pp. 79-82 (Proceedings of IEEE Sensors).
Download
@inproceedings{21efb229afe34f9f8124811446b58c54,
title = "Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization",
abstract = "Ion mobility spectrometry (IMS) is a widely used method for detecting low ppb-level concentrations of hazardous compounds, such as chemical warfare agents, explosives and pollutants in air. Simple instrumentation combined with high sensitivity and high selectivity are major advantages of this technique. This paper presents both a novel concept of a miniaturized IMS that is capable of identifying hazardous compounds in air at low ppb-levels and a numerical model based on finite element analysis for fast system design. The model described here considers for the fist time all significant physical effects on the ion transport in an IMS, such as diffusion, coulomb repulsion, electric fields and gas flows. The simulations perfectly match the observations made with our experimental setup. This allowed rapid system optimization towards the highest performance possible under the given physical and economic constraints.",
author = "S. Barth and W. Baether and S. Zimmermann",
year = "2007",
month = dec,
day = "17",
doi = "10.1109/ICSENS.2007.4388340",
language = "English",
isbn = "9781424412617",
series = "Proceedings of IEEE Sensors",
pages = "79--82",
booktitle = "SENSORS, 2007 IEEE",
note = "6th IEEE Conference on SENSORS, IEEE SENSORS 2007 ; Conference date: 28-10-2007 Through 31-10-2007",
url = "http://ewh.ieee.org/conf/sensors2007/",

}

Download

TY - GEN

T1 - Concept of a Miniaturized Ion Mobility Spectrometer and a Numerical Model for Fast System Design and Optimization

AU - Barth, S.

AU - Baether, W.

AU - Zimmermann, S.

N1 - Conference code: 6

PY - 2007/12/17

Y1 - 2007/12/17

N2 - Ion mobility spectrometry (IMS) is a widely used method for detecting low ppb-level concentrations of hazardous compounds, such as chemical warfare agents, explosives and pollutants in air. Simple instrumentation combined with high sensitivity and high selectivity are major advantages of this technique. This paper presents both a novel concept of a miniaturized IMS that is capable of identifying hazardous compounds in air at low ppb-levels and a numerical model based on finite element analysis for fast system design. The model described here considers for the fist time all significant physical effects on the ion transport in an IMS, such as diffusion, coulomb repulsion, electric fields and gas flows. The simulations perfectly match the observations made with our experimental setup. This allowed rapid system optimization towards the highest performance possible under the given physical and economic constraints.

AB - Ion mobility spectrometry (IMS) is a widely used method for detecting low ppb-level concentrations of hazardous compounds, such as chemical warfare agents, explosives and pollutants in air. Simple instrumentation combined with high sensitivity and high selectivity are major advantages of this technique. This paper presents both a novel concept of a miniaturized IMS that is capable of identifying hazardous compounds in air at low ppb-levels and a numerical model based on finite element analysis for fast system design. The model described here considers for the fist time all significant physical effects on the ion transport in an IMS, such as diffusion, coulomb repulsion, electric fields and gas flows. The simulations perfectly match the observations made with our experimental setup. This allowed rapid system optimization towards the highest performance possible under the given physical and economic constraints.

UR - http://www.scopus.com/inward/record.url?scp=48349118705&partnerID=8YFLogxK

U2 - 10.1109/ICSENS.2007.4388340

DO - 10.1109/ICSENS.2007.4388340

M3 - Conference contribution

AN - SCOPUS:48349118705

SN - 9781424412617

T3 - Proceedings of IEEE Sensors

SP - 79

EP - 82

BT - SENSORS, 2007 IEEE

T2 - 6th IEEE Conference on SENSORS

Y2 - 28 October 2007 through 31 October 2007

ER -

By the same author(s)