Concept for high speed vocal cord imaging with swept-source optical coherence tomography

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Authors

  • Miroslav Zabic
  • Sara Sharifpourboushehri
  • Lennart Müller-Wirts
  • Hannes Benecke
  • Alexander Heisterkamp
  • Heiko Meyer
  • Tammo Ripken

Research Organisations

External Research Organisations

  • Laser Zentrum Hannover e.V. (LZH)
View graph of relations

Details

Original languageEnglish
Title of host publicationOptical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019
PublisherSPIE
Number of pages8
ISBN (electronic)9781510623484
Publication statusPublished - 2019
EventOptical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019 - San Francisco, United States
Duration: 2 Feb 20192 Feb 2019

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume10853
ISSN (Print)1605-7422
ISSN (electronic)2410-9045

Abstract

Optical coherence tomography (OCT) enables non-invasive depth-resolved investigation of laryngeal tissue. However, with conventional systems, OCT cross-sectional images of vibrating vocal cords always suffer from motion artifacts. This is the case even at low phonation frequencies of about 100 Hz. Motion artifacts of predictable repetitive movements can be avoided with carefully timed acquisitions. Irregular, non-repetitive movements, e.g. disturbed vocal cord vibration caused by laryngeal disorders, require different strategies, such as the use of high frame rates. We present a novel concept for dynamic vocal cord imaging with a high speed 1.6 MHz swept-source OCT system. Due to the high image rate, a graphics processing unit (GPU) based signal processing software has been developed in order to obtain real time OCT images. To demonstrate the feasibility of our approach on vibrating samples, we present a laboratory setup which includes a MHz swept source for OCT. To enable the transfer of our setup to clinical applications a concept for a curved rigid laryngoscope design, integrating the optical components for high-speed OCT, is proposed.

Keywords

    high-speed imaging, laryngoscopy, motion artifacts, optical coherence tomography, vocal cords

ASJC Scopus subject areas

Cite this

Concept for high speed vocal cord imaging with swept-source optical coherence tomography. / Zabic, Miroslav; Sharifpourboushehri, Sara; Müller-Wirts, Lennart et al.
Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019. SPIE, 2019. 108530H (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 10853).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Zabic, M, Sharifpourboushehri, S, Müller-Wirts, L, Benecke, H, Heisterkamp, A, Meyer, H & Ripken, T 2019, Concept for high speed vocal cord imaging with swept-source optical coherence tomography. in Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019., 108530H, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 10853, SPIE, Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019, San Francisco, United States, 2 Feb 2019. https://doi.org/10.1117/12.2509538, https://doi.org/10.15488/10253
Zabic, M., Sharifpourboushehri, S., Müller-Wirts, L., Benecke, H., Heisterkamp, A., Meyer, H., & Ripken, T. (2019). Concept for high speed vocal cord imaging with swept-source optical coherence tomography. In Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019 Article 108530H (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 10853). SPIE. https://doi.org/10.1117/12.2509538, https://doi.org/10.15488/10253
Zabic M, Sharifpourboushehri S, Müller-Wirts L, Benecke H, Heisterkamp A, Meyer H et al. Concept for high speed vocal cord imaging with swept-source optical coherence tomography. In Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019. SPIE. 2019. 108530H. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE). doi: 10.1117/12.2509538, 10.15488/10253
Zabic, Miroslav ; Sharifpourboushehri, Sara ; Müller-Wirts, Lennart et al. / Concept for high speed vocal cord imaging with swept-source optical coherence tomography. Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019. SPIE, 2019. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE).
Download
@inproceedings{ebb468015c9f4634a8b8fb61a414ee3c,
title = "Concept for high speed vocal cord imaging with swept-source optical coherence tomography",
abstract = "Optical coherence tomography (OCT) enables non-invasive depth-resolved investigation of laryngeal tissue. However, with conventional systems, OCT cross-sectional images of vibrating vocal cords always suffer from motion artifacts. This is the case even at low phonation frequencies of about 100 Hz. Motion artifacts of predictable repetitive movements can be avoided with carefully timed acquisitions. Irregular, non-repetitive movements, e.g. disturbed vocal cord vibration caused by laryngeal disorders, require different strategies, such as the use of high frame rates. We present a novel concept for dynamic vocal cord imaging with a high speed 1.6 MHz swept-source OCT system. Due to the high image rate, a graphics processing unit (GPU) based signal processing software has been developed in order to obtain real time OCT images. To demonstrate the feasibility of our approach on vibrating samples, we present a laboratory setup which includes a MHz swept source for OCT. To enable the transfer of our setup to clinical applications a concept for a curved rigid laryngoscope design, integrating the optical components for high-speed OCT, is proposed.",
keywords = "high-speed imaging, laryngoscopy, motion artifacts, optical coherence tomography, vocal cords",
author = "Miroslav Zabic and Sara Sharifpourboushehri and Lennart M{\"u}ller-Wirts and Hannes Benecke and Alexander Heisterkamp and Heiko Meyer and Tammo Ripken",
note = "Funding information: We gratefully acknowledge the Europ{\"a}ischer Fonds f{\"u}r regionale Entwicklung (EFRE) and the state Niedersachsen for funding the project “OPhonLas - Algorithmen und Optik”.; Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019 ; Conference date: 02-02-2019 Through 02-02-2019",
year = "2019",
doi = "10.1117/12.2509538",
language = "English",
series = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
publisher = "SPIE",
booktitle = "Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019",
address = "United States",

}

Download

TY - GEN

T1 - Concept for high speed vocal cord imaging with swept-source optical coherence tomography

AU - Zabic, Miroslav

AU - Sharifpourboushehri, Sara

AU - Müller-Wirts, Lennart

AU - Benecke, Hannes

AU - Heisterkamp, Alexander

AU - Meyer, Heiko

AU - Ripken, Tammo

N1 - Funding information: We gratefully acknowledge the Europäischer Fonds für regionale Entwicklung (EFRE) and the state Niedersachsen for funding the project “OPhonLas - Algorithmen und Optik”.

PY - 2019

Y1 - 2019

N2 - Optical coherence tomography (OCT) enables non-invasive depth-resolved investigation of laryngeal tissue. However, with conventional systems, OCT cross-sectional images of vibrating vocal cords always suffer from motion artifacts. This is the case even at low phonation frequencies of about 100 Hz. Motion artifacts of predictable repetitive movements can be avoided with carefully timed acquisitions. Irregular, non-repetitive movements, e.g. disturbed vocal cord vibration caused by laryngeal disorders, require different strategies, such as the use of high frame rates. We present a novel concept for dynamic vocal cord imaging with a high speed 1.6 MHz swept-source OCT system. Due to the high image rate, a graphics processing unit (GPU) based signal processing software has been developed in order to obtain real time OCT images. To demonstrate the feasibility of our approach on vibrating samples, we present a laboratory setup which includes a MHz swept source for OCT. To enable the transfer of our setup to clinical applications a concept for a curved rigid laryngoscope design, integrating the optical components for high-speed OCT, is proposed.

AB - Optical coherence tomography (OCT) enables non-invasive depth-resolved investigation of laryngeal tissue. However, with conventional systems, OCT cross-sectional images of vibrating vocal cords always suffer from motion artifacts. This is the case even at low phonation frequencies of about 100 Hz. Motion artifacts of predictable repetitive movements can be avoided with carefully timed acquisitions. Irregular, non-repetitive movements, e.g. disturbed vocal cord vibration caused by laryngeal disorders, require different strategies, such as the use of high frame rates. We present a novel concept for dynamic vocal cord imaging with a high speed 1.6 MHz swept-source OCT system. Due to the high image rate, a graphics processing unit (GPU) based signal processing software has been developed in order to obtain real time OCT images. To demonstrate the feasibility of our approach on vibrating samples, we present a laboratory setup which includes a MHz swept source for OCT. To enable the transfer of our setup to clinical applications a concept for a curved rigid laryngoscope design, integrating the optical components for high-speed OCT, is proposed.

KW - high-speed imaging

KW - laryngoscopy

KW - motion artifacts

KW - optical coherence tomography

KW - vocal cords

UR - http://www.scopus.com/inward/record.url?scp=85066791878&partnerID=8YFLogxK

U2 - 10.1117/12.2509538

DO - 10.1117/12.2509538

M3 - Conference contribution

AN - SCOPUS:85066791878

T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

BT - Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019

PB - SPIE

T2 - Optical Imaging, Therapeutics, and Advanced Technology in Head and Neck Surgery and Otolaryngology 2019

Y2 - 2 February 2019 through 2 February 2019

ER -