Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement

Research output: Contribution to journalArticleResearchpeer review

Authors

Research Organisations

View graph of relations

Details

Original languageEnglish
Pages (from-to)173-177
Number of pages5
JournalBIOINFORMATICS
Volume19
Issue number2
Publication statusPublished - 22 Jan 2003

Abstract

Motivation: 2D fluorescence spectra provide information from intracellular compounds. Fluorophores like trytophan, tyrosine and phenylalanin as well as NADH and flavins make the corresponding measurement systems very important for bioprocess supervision and control. The evaluation is usually based on chemometric modelling using for their calibration procedure off-line measurements of the desired process variables. Due to the data driven approach lots of off-line measurements are required. Here a methodology is presented, which enables to perform a calibration procedure of chemometric models without any further measurement. Results: The necessary information for the calibration procedure is provided by means of the a priori knowledge about the process, i.e. a mathematical model, whose model parameters are estimated during the calibration procedure, as well as the fact that the substrate should be consumed at the end of the process run. The new methodology for chemometric calibration is applied for a batch cultivation of aerobically grown S. cerevisiae on the glucose Schatzmann medium. As will be presented the chemometric models, which are determined by this method, can be used for prediction during new process runs.

ASJC Scopus subject areas

Cite this

Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement. / Solle, D.; Geissler, D.; Stärk, E. et al.
In: BIOINFORMATICS, Vol. 19, No. 2, 22.01.2003, p. 173-177.

Research output: Contribution to journalArticleResearchpeer review

Solle D, Geissler D, Stärk E, Scheper T, Hitzmann B. Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement. BIOINFORMATICS. 2003 Jan 22;19(2):173-177. doi: 10.1093/bioinformatics/19.2.173
Solle, D. ; Geissler, D. ; Stärk, E. et al. / Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement. In: BIOINFORMATICS. 2003 ; Vol. 19, No. 2. pp. 173-177.
Download
@article{0f217bd6c82e4de58454bb6dc888ce04,
title = "Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement",
abstract = "Motivation: 2D fluorescence spectra provide information from intracellular compounds. Fluorophores like trytophan, tyrosine and phenylalanin as well as NADH and flavins make the corresponding measurement systems very important for bioprocess supervision and control. The evaluation is usually based on chemometric modelling using for their calibration procedure off-line measurements of the desired process variables. Due to the data driven approach lots of off-line measurements are required. Here a methodology is presented, which enables to perform a calibration procedure of chemometric models without any further measurement. Results: The necessary information for the calibration procedure is provided by means of the a priori knowledge about the process, i.e. a mathematical model, whose model parameters are estimated during the calibration procedure, as well as the fact that the substrate should be consumed at the end of the process run. The new methodology for chemometric calibration is applied for a batch cultivation of aerobically grown S. cerevisiae on the glucose Schatzmann medium. As will be presented the chemometric models, which are determined by this method, can be used for prediction during new process runs.",
author = "D. Solle and D. Geissler and E. St{\"a}rk and T. Scheper and B. Hitzmann",
year = "2003",
month = jan,
day = "22",
doi = "10.1093/bioinformatics/19.2.173",
language = "English",
volume = "19",
pages = "173--177",
journal = "BIOINFORMATICS",
issn = "1367-4803",
publisher = "Oxford University Press",
number = "2",

}

Download

TY - JOUR

T1 - Chemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement

AU - Solle, D.

AU - Geissler, D.

AU - Stärk, E.

AU - Scheper, T.

AU - Hitzmann, B.

PY - 2003/1/22

Y1 - 2003/1/22

N2 - Motivation: 2D fluorescence spectra provide information from intracellular compounds. Fluorophores like trytophan, tyrosine and phenylalanin as well as NADH and flavins make the corresponding measurement systems very important for bioprocess supervision and control. The evaluation is usually based on chemometric modelling using for their calibration procedure off-line measurements of the desired process variables. Due to the data driven approach lots of off-line measurements are required. Here a methodology is presented, which enables to perform a calibration procedure of chemometric models without any further measurement. Results: The necessary information for the calibration procedure is provided by means of the a priori knowledge about the process, i.e. a mathematical model, whose model parameters are estimated during the calibration procedure, as well as the fact that the substrate should be consumed at the end of the process run. The new methodology for chemometric calibration is applied for a batch cultivation of aerobically grown S. cerevisiae on the glucose Schatzmann medium. As will be presented the chemometric models, which are determined by this method, can be used for prediction during new process runs.

AB - Motivation: 2D fluorescence spectra provide information from intracellular compounds. Fluorophores like trytophan, tyrosine and phenylalanin as well as NADH and flavins make the corresponding measurement systems very important for bioprocess supervision and control. The evaluation is usually based on chemometric modelling using for their calibration procedure off-line measurements of the desired process variables. Due to the data driven approach lots of off-line measurements are required. Here a methodology is presented, which enables to perform a calibration procedure of chemometric models without any further measurement. Results: The necessary information for the calibration procedure is provided by means of the a priori knowledge about the process, i.e. a mathematical model, whose model parameters are estimated during the calibration procedure, as well as the fact that the substrate should be consumed at the end of the process run. The new methodology for chemometric calibration is applied for a batch cultivation of aerobically grown S. cerevisiae on the glucose Schatzmann medium. As will be presented the chemometric models, which are determined by this method, can be used for prediction during new process runs.

UR - http://www.scopus.com/inward/record.url?scp=0037316476&partnerID=8YFLogxK

U2 - 10.1093/bioinformatics/19.2.173

DO - 10.1093/bioinformatics/19.2.173

M3 - Article

C2 - 12538236

AN - SCOPUS:0037316476

VL - 19

SP - 173

EP - 177

JO - BIOINFORMATICS

JF - BIOINFORMATICS

SN - 1367-4803

IS - 2

ER -

By the same author(s)