Challenges in Calibration of the Measurement of Partial Discharges at Ultrahigh Frequencies in Power Transformers

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Asghar Akbari Azirani
  • Peter Werle
  • Mohammad Esmaeil Akbari Azirani
  • Hassan Reza Mirzaei

External Research Organisations

  • Zanjan University
  • K.N. Toosi University of Technology
View graph of relations

Details

Original languageEnglish
Article number7414228
Pages (from-to)27-34
Number of pages8
JournalIEEE Electrical Insulation Magazine
Volume32
Issue number2
Publication statusPublished - 25 Feb 2016

Abstract

The detection and measurement of partial discharge (PD) is a well-known method for evaluating the insulation performance of power transformers. According to the IEC 60270 standard, the apparent charge is measured in a frequency range below 1 MHz using an electrical circuit which quantifies only a portion of the discharge energy conducted to the PD detector through the conductors. However, it is also well known that the PD energy is not only conducted but also transmitted via electromagnetic (EM) and optic waves, acoustic waves, and thermal energy.

Keywords

    Power transformer, Ultrahigh frequency partial discharge detection, partial discharge measurement

ASJC Scopus subject areas

Cite this

Challenges in Calibration of the Measurement of Partial Discharges at Ultrahigh Frequencies in Power Transformers. / Akbari Azirani, Asghar; Werle, Peter; Akbari Azirani, Mohammad Esmaeil et al.
In: IEEE Electrical Insulation Magazine, Vol. 32, No. 2, 7414228, 25.02.2016, p. 27-34.

Research output: Contribution to journalArticleResearchpeer review

Akbari Azirani A, Werle P, Akbari Azirani ME, Mirzaei HR. Challenges in Calibration of the Measurement of Partial Discharges at Ultrahigh Frequencies in Power Transformers. IEEE Electrical Insulation Magazine. 2016 Feb 25;32(2):27-34. 7414228. doi: 10.1109/MEI.2016.7414228
Download
@article{15c198c1c98c4ef49f259bb44ccf3799,
title = "Challenges in Calibration of the Measurement of Partial Discharges at Ultrahigh Frequencies in Power Transformers",
abstract = "The detection and measurement of partial discharge (PD) is a well-known method for evaluating the insulation performance of power transformers. According to the IEC 60270 standard, the apparent charge is measured in a frequency range below 1 MHz using an electrical circuit which quantifies only a portion of the discharge energy conducted to the PD detector through the conductors. However, it is also well known that the PD energy is not only conducted but also transmitted via electromagnetic (EM) and optic waves, acoustic waves, and thermal energy.",
keywords = "Power transformer, Ultrahigh frequency partial discharge detection, partial discharge measurement",
author = "{Akbari Azirani}, Asghar and Peter Werle and {Akbari Azirani}, {Mohammad Esmaeil} and Mirzaei, {Hassan Reza}",
year = "2016",
month = feb,
day = "25",
doi = "10.1109/MEI.2016.7414228",
language = "English",
volume = "32",
pages = "27--34",
journal = "IEEE Electrical Insulation Magazine",
issn = "0883-7554",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

Download

TY - JOUR

T1 - Challenges in Calibration of the Measurement of Partial Discharges at Ultrahigh Frequencies in Power Transformers

AU - Akbari Azirani, Asghar

AU - Werle, Peter

AU - Akbari Azirani, Mohammad Esmaeil

AU - Mirzaei, Hassan Reza

PY - 2016/2/25

Y1 - 2016/2/25

N2 - The detection and measurement of partial discharge (PD) is a well-known method for evaluating the insulation performance of power transformers. According to the IEC 60270 standard, the apparent charge is measured in a frequency range below 1 MHz using an electrical circuit which quantifies only a portion of the discharge energy conducted to the PD detector through the conductors. However, it is also well known that the PD energy is not only conducted but also transmitted via electromagnetic (EM) and optic waves, acoustic waves, and thermal energy.

AB - The detection and measurement of partial discharge (PD) is a well-known method for evaluating the insulation performance of power transformers. According to the IEC 60270 standard, the apparent charge is measured in a frequency range below 1 MHz using an electrical circuit which quantifies only a portion of the discharge energy conducted to the PD detector through the conductors. However, it is also well known that the PD energy is not only conducted but also transmitted via electromagnetic (EM) and optic waves, acoustic waves, and thermal energy.

KW - Power transformer

KW - Ultrahigh frequency partial discharge detection

KW - partial discharge measurement

UR - http://www.scopus.com/inward/record.url?scp=84963812099&partnerID=8YFLogxK

U2 - 10.1109/MEI.2016.7414228

DO - 10.1109/MEI.2016.7414228

M3 - Article

VL - 32

SP - 27

EP - 34

JO - IEEE Electrical Insulation Magazine

JF - IEEE Electrical Insulation Magazine

SN - 0883-7554

IS - 2

M1 - 7414228

ER -

By the same author(s)