Original languageEnglish
Title of host publicationProceedings of the 7th International Conference on Properties and Applications of Dielectric Materials
Pages290-293
Number of pages4
Publication statusPublished - 2003
Event7th International Conference on Properties and Applications of Dielectric Materials - Nagoya, Japan
Duration: 1 Jun 20035 Jun 2003

Publication series

Name International Conference on Properties and Applications of Properties and Applications of Dielectric Materials
Volume3
ISSN (Print)1081-7735

Abstract

In this work the possibility of the dielectric response measurement for the evaluation of the actual status of insulation system of high voltage rotating machines are investigated. As test object, model stator bars were used, which are close to real stator bars of high voltage rotating machines. An accelerated ageing procedure was applied to the model bars and the dielectric response was measured in time domain. The dielectric response function was calculated from depolarization current measuring results and the change of this function was evaluated.

ASJC Scopus subject areas

Cite this

Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines. / Farahani, M.; Borsi, H.; Gockenbach, E.
Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials. 2003. p. 290-293 ( International Conference on Properties and Applications of Properties and Applications of Dielectric Materials ; Vol. 3).

Research output: Chapter in book/report/conference proceedingConference contributionResearchpeer review

Farahani, M, Borsi, H & Gockenbach, E 2003, Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines. in Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials. International Conference on Properties and Applications of Properties and Applications of Dielectric Materials , vol. 3, pp. 290-293, 7th International Conference on Properties and Applications of Dielectric Materials, Nagoya, Japan, 1 Jun 2003. https://doi.org/10.1109/ICPADM.2003.1218409
Farahani, M., Borsi, H., & Gockenbach, E. (2003). Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines. In Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (pp. 290-293). ( International Conference on Properties and Applications of Properties and Applications of Dielectric Materials ; Vol. 3). https://doi.org/10.1109/ICPADM.2003.1218409
Farahani M, Borsi H, Gockenbach E. Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines. In Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials. 2003. p. 290-293. ( International Conference on Properties and Applications of Properties and Applications of Dielectric Materials ). doi: 10.1109/ICPADM.2003.1218409
Farahani, M. ; Borsi, H. ; Gockenbach, E. / Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines. Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials. 2003. pp. 290-293 ( International Conference on Properties and Applications of Properties and Applications of Dielectric Materials ).
Download
@inproceedings{78ec1a3d6c8443cd9e5f98634dc5268f,
title = "Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines",
abstract = "In this work the possibility of the dielectric response measurement for the evaluation of the actual status of insulation system of high voltage rotating machines are investigated. As test object, model stator bars were used, which are close to real stator bars of high voltage rotating machines. An accelerated ageing procedure was applied to the model bars and the dielectric response was measured in time domain. The dielectric response function was calculated from depolarization current measuring results and the change of this function was evaluated.",
author = "M. Farahani and H. Borsi and E. Gockenbach",
note = "Copyright: Copyright 2008 Elsevier B.V., All rights reserved.; 7th International Conference on Properties and Applications of Dielectric Materials ; Conference date: 01-06-2003 Through 05-06-2003",
year = "2003",
doi = "10.1109/ICPADM.2003.1218409",
language = "English",
isbn = "0-7803-7725-7 ",
series = " International Conference on Properties and Applications of Properties and Applications of Dielectric Materials ",
pages = "290--293",
booktitle = "Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials",

}

Download

TY - GEN

T1 - Calculation and measurement of dielectric response function in insulation systems of high voltage rotating machines

AU - Farahani, M.

AU - Borsi, H.

AU - Gockenbach, E.

N1 - Copyright: Copyright 2008 Elsevier B.V., All rights reserved.

PY - 2003

Y1 - 2003

N2 - In this work the possibility of the dielectric response measurement for the evaluation of the actual status of insulation system of high voltage rotating machines are investigated. As test object, model stator bars were used, which are close to real stator bars of high voltage rotating machines. An accelerated ageing procedure was applied to the model bars and the dielectric response was measured in time domain. The dielectric response function was calculated from depolarization current measuring results and the change of this function was evaluated.

AB - In this work the possibility of the dielectric response measurement for the evaluation of the actual status of insulation system of high voltage rotating machines are investigated. As test object, model stator bars were used, which are close to real stator bars of high voltage rotating machines. An accelerated ageing procedure was applied to the model bars and the dielectric response was measured in time domain. The dielectric response function was calculated from depolarization current measuring results and the change of this function was evaluated.

UR - http://www.scopus.com/inward/record.url?scp=0141939401&partnerID=8YFLogxK

U2 - 10.1109/ICPADM.2003.1218409

DO - 10.1109/ICPADM.2003.1218409

M3 - Conference contribution

AN - SCOPUS:0141939401

SN - 0-7803-7725-7

T3 - International Conference on Properties and Applications of Properties and Applications of Dielectric Materials

SP - 290

EP - 293

BT - Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials

T2 - 7th International Conference on Properties and Applications of Dielectric Materials

Y2 - 1 June 2003 through 5 June 2003

ER -