Automatische Qualitätskontrolle medizinischer Implantate

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Berend Denkena
  • Wolfram Acker
View graph of relations

Details

Translated title of the contributionAutomatic quality inspection of medical implants
Original languageGerman
Pages (from-to)121-124
Number of pages4
JournalZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb
Volume100
Issue number3
Publication statusPublished - Mar 2005

Abstract

Hip and knee prostheses are very complex products with high quality standards. In the research project "Optical geometry acquisition of medical implants and prostheses", methods for the two and three dimensional quality assurance are investigated. The two-dimensional measurement checks the quality of the surface. The three-dimensional enables a new examination method, the Model-based-RSA, as well as a control of the dimensional accuracy.

ASJC Scopus subject areas

Cite this

Automatische Qualitätskontrolle medizinischer Implantate. / Denkena, Berend; Acker, Wolfram.
In: ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, Vol. 100, No. 3, 03.2005, p. 121-124.

Research output: Contribution to journalArticleResearchpeer review

Denkena, B & Acker, W 2005, 'Automatische Qualitätskontrolle medizinischer Implantate', ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, vol. 100, no. 3, pp. 121-124. https://doi.org/10.3139/104.100874
Denkena, B., & Acker, W. (2005). Automatische Qualitätskontrolle medizinischer Implantate. ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb, 100(3), 121-124. https://doi.org/10.3139/104.100874
Denkena B, Acker W. Automatische Qualitätskontrolle medizinischer Implantate. ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb. 2005 Mar;100(3):121-124. doi: 10.3139/104.100874
Denkena, Berend ; Acker, Wolfram. / Automatische Qualitätskontrolle medizinischer Implantate. In: ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb. 2005 ; Vol. 100, No. 3. pp. 121-124.
Download
@article{dccaf21887b245eca53d257a84fe097d,
title = "Automatische Qualit{\"a}tskontrolle medizinischer Implantate",
abstract = "Hip and knee prostheses are very complex products with high quality standards. In the research project {"}Optical geometry acquisition of medical implants and prostheses{"}, methods for the two and three dimensional quality assurance are investigated. The two-dimensional measurement checks the quality of the surface. The three-dimensional enables a new examination method, the Model-based-RSA, as well as a control of the dimensional accuracy.",
author = "Berend Denkena and Wolfram Acker",
year = "2005",
month = mar,
doi = "10.3139/104.100874",
language = "Deutsch",
volume = "100",
pages = "121--124",
number = "3",

}

Download

TY - JOUR

T1 - Automatische Qualitätskontrolle medizinischer Implantate

AU - Denkena, Berend

AU - Acker, Wolfram

PY - 2005/3

Y1 - 2005/3

N2 - Hip and knee prostheses are very complex products with high quality standards. In the research project "Optical geometry acquisition of medical implants and prostheses", methods for the two and three dimensional quality assurance are investigated. The two-dimensional measurement checks the quality of the surface. The three-dimensional enables a new examination method, the Model-based-RSA, as well as a control of the dimensional accuracy.

AB - Hip and knee prostheses are very complex products with high quality standards. In the research project "Optical geometry acquisition of medical implants and prostheses", methods for the two and three dimensional quality assurance are investigated. The two-dimensional measurement checks the quality of the surface. The three-dimensional enables a new examination method, the Model-based-RSA, as well as a control of the dimensional accuracy.

UR - http://www.scopus.com/inward/record.url?scp=17044438649&partnerID=8YFLogxK

U2 - 10.3139/104.100874

DO - 10.3139/104.100874

M3 - Artikel

AN - SCOPUS:17044438649

VL - 100

SP - 121

EP - 124

JO - ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb

JF - ZWF Zeitschrift fuer Wirtschaftlichen Fabrikbetrieb

SN - 0947-0085

IS - 3

ER -