An aluminum optical clock setup and its evaluation using Ca+

Research output: ThesisDoctoral thesis

Authors

  • Johannes Albrecht Kramer
View graph of relations

Details

Original languageEnglish
QualificationDoctor rerum naturalium
Awarding Institution
Supervised by
Date of Award15 Jul 2022
Place of PublicationHannover
Publication statusPublished - 2023

Abstract

This thesis reports about the progress of the aluminum ion clock that is set up at the German National Metrological Institute, Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig. All known relevant systematic frequency shifts are discussed. The systematic shifts were measured on the co-trapped logic ion 40Ca+, which is advantageous due to its higher sensitivity to external fields compared to 27Al+. The observation of the clock transition of 27Al+ and an analysis of the detection error is described.

Cite this

An aluminum optical clock setup and its evaluation using Ca+. / Kramer, Johannes Albrecht.
Hannover, 2023. 213 p.

Research output: ThesisDoctoral thesis

Kramer, JA 2023, 'An aluminum optical clock setup and its evaluation using Ca+', Doctor rerum naturalium, Leibniz University Hannover, Hannover. https://doi.org/10.15488/13300
Kramer, J. A. (2023). An aluminum optical clock setup and its evaluation using Ca+. [Doctoral thesis, Leibniz University Hannover]. https://doi.org/10.15488/13300
Kramer JA. An aluminum optical clock setup and its evaluation using Ca+. Hannover, 2023. 213 p. doi: 10.15488/13300
Kramer, Johannes Albrecht. / An aluminum optical clock setup and its evaluation using Ca+. Hannover, 2023. 213 p.
Download
@phdthesis{86cab4c31f8f47828045e7e1ffea08f3,
title = "An aluminum optical clock setup and its evaluation using Ca+",
abstract = "This thesis reports about the progress of the aluminum ion clock that is set up at the German National Metrological Institute, Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig. All known relevant systematic frequency shifts are discussed. The systematic shifts were measured on the co-trapped logic ion 40Ca+, which is advantageous due to its higher sensitivity to external fields compared to 27Al+. The observation of the clock transition of 27Al+ and an analysis of the detection error is described.",
author = "Kramer, {Johannes Albrecht}",
note = "Doctoral thesis",
year = "2023",
doi = "10.15488/13300",
language = "English",
school = "Leibniz University Hannover",

}

Download

TY - BOOK

T1 - An aluminum optical clock setup and its evaluation using Ca+

AU - Kramer, Johannes Albrecht

N1 - Doctoral thesis

PY - 2023

Y1 - 2023

N2 - This thesis reports about the progress of the aluminum ion clock that is set up at the German National Metrological Institute, Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig. All known relevant systematic frequency shifts are discussed. The systematic shifts were measured on the co-trapped logic ion 40Ca+, which is advantageous due to its higher sensitivity to external fields compared to 27Al+. The observation of the clock transition of 27Al+ and an analysis of the detection error is described.

AB - This thesis reports about the progress of the aluminum ion clock that is set up at the German National Metrological Institute, Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig. All known relevant systematic frequency shifts are discussed. The systematic shifts were measured on the co-trapped logic ion 40Ca+, which is advantageous due to its higher sensitivity to external fields compared to 27Al+. The observation of the clock transition of 27Al+ and an analysis of the detection error is described.

U2 - 10.15488/13300

DO - 10.15488/13300

M3 - Doctoral thesis

CY - Hannover

ER -

By the same author(s)